Introduction:

The SICK S30B-2011BA S300 Standard safety laser scanner offers 2m protection. It meets Type 3 SIL 2 and PL d requirements.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: SICK
Series: S300 Standard
Part Number: S30B-2011BA
Type: Safety Laser Scanner
Condition: In Stock
Origin: U.S.A
Weight: 1.2
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The SICK S30B-2011BA belongs to the S300 Standard family of safety laser scanners.
This model operates without a system plug as a standalone indoor sensor.
The device provides a protective field range of 2 m.
In addition, the warning field reaches 8 m at 15% reflectivity.
The maximum distance measuring range extends to 30 m.
Consequently, the S30B-2011BA suits stationary machinery and mobile platforms.
It connects via a male M12 5-pin connector for easy installation.


Technical Specifications

Field and Scanning Data

This scanner covers a scanning angle of 270° .
You can configure the resolution from 30 mm up to 70 mm.
Available resolution settings include 30 mm, 40 mm, 50 mm, and 70 mm.
The angular resolution is 0.5° for reliable detection.
Response time measures 80 ms for consistent performance.
The protective field supplement adds 100 mm of safety margin.
This model uses triple field sets with 3 fields total.
It supports 1 field set and 1 monitoring case.
Multiple sampling ranges from 2 to 16, fully configurable.
Automatic reset delay adjusts from 2 seconds to 60 seconds.

Safety Ratings and Standards

The SICK S30B-2011BA complies with Type 3 per IEC 61496.
Its safety integrity level is SIL 2 according to IEC 61508.
For ISO standards, the category equals Category 3 per EN ISO 13849.
The performance level is PL d under the same standard.
The PFHD value equals 8.0 x 10-8 for high reliability.
Mission time reaches 20 years per EN ISO 13849.
In a fault condition, at least one OSSD switches to the OFF state.

Laser and Optical Data

The S30B-2011BA uses a pulsed laser diode as the light source.
Wavelength equals 905 nm for consistent performance.
Detectable remission factor ranges from 1.8% to over 1,000% including reflectors.
Laser class is Class 1 per IEC 60825-1 and 21 CFR 1040.
Therefore, this device is completely eye-safe under normal operation.

Functions and Features

The SICK S30B-2011BA includes a restart interlock for safety.
External device monitoring (EDM) comes standard on this model.
Multiple sampling improves detection reliability in noisy environments.
Contour as a reference enables precise area positioning.
Integrated configuration memory stores all parameters locally.
Measured data output occurs via the RS-422 interface.
Safe SICK device communication uses EFI protocol.

Interfaces and I/O

Connection type uses a system plug with or without cable.
The device provides 5 universal I/Os for flexible wiring.
External device monitoring (EDM) uses 1 dedicated input.
Reset or restart function has 1 dedicated channel.
Standby mode uses 1 dedicated input as well.
For safety outputs, the S30B-2011BA offers 1 OSSD pair.
Application diagnostic outputs include 3 channels at 100 mA each.
Each OSSD output delivers 250 mA for reliable switching.

Configuration and Diagnostics

You configure the S30B-2011BA using a PC with CDS software.
The configuration and diagnostics interface is RS-232.
Transmission rate for configuration equals 38.4 kBaud.
For data output, the RS-422 interface runs at ≤ 500 kBaud.
EFI communication also supports ≤ 500 kBaud.
Maximum cable length for EFI reaches 50 m.
Recommended conductor cross section is 0.22 mm².

Power Requirements

Supply voltage Vs is 24 V DC with a range of 16.8 V to 30 V DC.
Typical power consumption equals 0.33 A .
Maximum power consumption reaches 1.7 A during operation.

Mechanical Data

Dimensions are 102 mm (W) x 152 mm (H) x 106 mm (D).
Product net weight equals 1.2 kg for stable mounting.
Housing material is aluminum die cast for durability.
Housing color is RAL 1021 (yellow) for high visibility.
The optics cover uses polycarbonate material.
Optics cover surface includes a scratch-resistant coating.

Environmental Ratings

Enclosure rating is IP65 per EN 60529.
Ambient operating temperature ranges from -10°C to +50°C .
Storage temperature spans from -25°C to +50°C .

Vibration and Shock Resistance

The SICK S30B-2011BA meets IEC 60068-2-6 and IEC 60068-2-64 standards.
It complies with IEC 60721-3-5 and IEC TR 60721-4-5 as well.
Class rating is 5M1 per IEC 60721-3-5.
For shock resistance, the device follows IEC 60068-2-27.
Continuous shock tolerance includes 50 m/s² at 11 ms.
It also withstands 100 m/s² at 16 ms.


Installation Guidelines

Mount the SICK S30B-2011BA on a rigid, vibration-free surface.
Ensure the 270° scanning area remains free of obstructions.
Keep the optics cover clean using a soft, lint-free cloth.
Do not install the device near intense ambient light sources.
Position the scanner at the correct height for your protective field.
Connect the M12 5-pin male connector securely to the system plug.
Use shielded cables for RS-422 connections to reduce electrical noise.
Configure the protective fields using CDS software on a PC.
After configuration, test each field with an appropriate test object.
Verify that the restart interlock and EDM function correctly.


Package Contents

  • 1 x SICK S30B-2011BA S300 Standard safety laser scanner

  • 1 x M12 5-pin male connector system plug

  • 1 x Quick start guide for installation reference

  • 1 x Mounting bracket set with screws

  • 1 x Protective cap for unused connectors


Frequently Asked Questions (FAQ)

1. Can the S30B-2011BA detect objects with very low reflectivity?

Yes, the SICK S30B-2011BA detects objects with only 1.8% remission. This includes black clothing and dark machine parts.

2. What is the difference between protective field and warning field?

The protective field stops the machine upon entry. The warning field triggers an alert but does not stop the S30B-2011BA .

3. Can I use this scanner outdoors or in direct sunlight?

This is an indoor model with IP65 rating. Direct sunlight may exceed ambient light limits and affect scanning performance.

4. How do I configure multiple sampling on this device?

Use CDS software to set multiple sampling from 2 to 16. Higher values reduce false trips but increase response time on the S30B-2011BA .

5. Does this model provide distance measurement data?

Yes, the SICK S30B-2011BA outputs measured data via RS-422. You can access distance values for diagnostic and monitoring purposes.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap