+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

SAI143-H63 Yokogawa | Isolated Input Module with HART Communication

Introduction:

Yokogawa SAI143-H63 Analog Input Module. 16 channels at 4-20mA with module isolation. Transmitter power supply with HART support.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Yokogawa
Series: SAI143 Series
Part Number: SAI143-H63
Type: Analog Input Module
Condition: In Stock
Origin: U.S.A
Weight: 0.52
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The Yokogawa SAI143-H63 is an analog input module with 16 channels. It accepts 4 to 20 mA signals from field transmitters. This module features full channel isolation for signal integrity. The Yokogawa SAI143-H63 includes a built-in transmitter power supply for 2-wire devices. Users trust this module for reliable analog measurement in Yokogawa CENTUM systems.


Technical Specifications

The SAI143-H63 delivers accurate analog input processing with isolation. Below are the complete technical details.

General Specifications

  • Manufacturer: Yokogawa for industrial automation reliability.

  • Product Type: Analog Input Module (16 channels, module isolation).

  • Product Number: SAI143-H63 for precise identification.

  • Model: SAI143 analog input module.

  • Weight (Pressure Clamp or MIL Cable): Approx. 0.34 kg.

  • Weight (With Signal Cable Interface Adapter): Approx. 0.39 kg.

Input Channel Specifications

  • Number of Input Channels: 16 channels with module isolation.

  • Rated Input Range: 4 to 20 mA standard analog signal.

  • Permissible Input Range: 0 to 25 mA maximum.

  • Input Impedance (Power-ON): 250 Ω + Current value.

  • Input Impedance (Power-OFF): 500 kΩ minimum.

  • Voltage Drop: Occurs in the input protection circuit inside the module.

Accuracy and Performance

  • Rated Accuracy (SAI143-S): ±16 µA (Input range 1 to 23 mA).

  • Rated Accuracy (SAI143-H): ±16 µA (Input range 0.05 to 23 mA).

  • Data Update Frequency: 40 ms for process monitoring.

  • Temperature Drift: ±16 µA per 10°C change.

  • Thermal Stability: Reliable across varying temperatures.

Transmitter Power Supply

  • Output at 20 mA: 16.15 V minimum for transmitter loop power.

  • Output at 0 mA: 26.4 V maximum.

  • Output Current Limit: 25 mA protection.

  • 2-Wire Setting: Available for all 16 channels simultaneously.

  • 4-Wire Setting: Individual channel configuration via setting pins.

  • Transmitter Power Supply ON/OFF Function: Available in 2-wire setting, for all 16 channels at the same time.

2/4-Wire Configuration

  • Individual Channel Setting: Each channel configurable independently.

  • Configuration Method: Changed by setting pins on the module.

  • Flexibility: Mix 2-wire and 4-wire transmitters on same module.

  • 2-Wire Mode: Module supplies power to the transmitter.

  • 4-Wire Mode: External power source supplies the transmitter.

Withstanding Voltage and Isolation

  • Between Input Signal and System: 1.5 kV AC for 1 minute.

  • Module Isolation: All 16 channels share common isolation.

  • Protection: Robust isolation for industrial noise immunity.

Power Consumption

  • 5 V System Maximum: 320 mA.

  • 24 V System Maximum: 550 mA.

  • Total Power: Moderate for 16-channel density.

External Connection Options

  • Pressure Clamp Terminal: For secure field wiring.

  • MIL Cable: For high-density connections.

  • Dedicated Signal Cable: For Yokogawa system integration.

PRM Support

  • Support PRM: Available (SAI143-H) for plant resource management.

  • HART Communication: Enabled on the -H63 suffix model.

  • Device Integration: Supports smart transmitter configuration.


Installation Guide

Follow these steps to install the Yokogawa SAI143-H63 correctly.

  1. Power Down the System: Turn off all power to the I/O rack.

  2. Locate the Slot: Find an available slot in the Yokogawa base plate.

  3. Insert the Module: Slide the SAI143-H63 into the slot until seated.

  4. Secure the Module: Lock the module using the retaining mechanism.

  5. Install Terminal: Attach pressure clamp terminal or MIL cable connection.

  6. Set 2/4-Wire Pins: Configure each channel using the setting pins.

  7. Wire 2-Wire Transmitters: Connect positive and negative leads for loop power.

  8. Wire 4-Wire Transmitters: Connect signal leads only (external power separate).

  9. Verify Input Range: Ensure signal stays within 4 to 20 mA rated range.

  10. Apply Power: Turn on the system power to the I/O rack.

  11. Check Status LEDs: Verify module operation and channel status.

  12. Configure in System: Set input range and scaling in CENTUM configuration.

  13. Test HART Communication: Confirm digital communication on HART channels.

Installation Notes

  • The module provides 16 analog input channels with module isolation.

  • Data update frequency is 40 ms for all channels.

  • Transmitter power supply ON/OFF applies to all 16 channels simultaneously.

  • 2/4-wire setting uses individual pins per channel.

  • Withstanding voltage is 1.5 kV AC for 1 minute.


Packaging List

This unit ships as a new and original product.

  • Yokogawa SAI143-H63 Analog Input Module

  • Setting pins for 2/4-wire configuration (pre-installed)

  • Product data sheet

  • Anti-static factory packaging box


Frequently Asked Questions (FAQ)

1. How many input channels does the SAI143-H63 provide?
The Yokogawa SAI143-H63 provides 16 analog input channels. All channels share module isolation for signal integrity.

2. Does this module supply power to 2-wire transmitters?
Yes, the SAI143-H63 includes a transmitter power supply. In 2-wire setting, it supplies 16.15 V minimum at 20 mA to all 16 channels simultaneously.

3. What is the accuracy of the SAI143-H63 analog inputs?
The Yokogawa SAI143-H63 provides ±16 µA accuracy. For the -H model, this applies across the input range of 0.05 to 23 mA.

4. How do I configure 2-wire or 4-wire mode on this module?
The SAI143-H63 uses setting pins for individual channel configuration. Each channel has pins to select 2-wire or 4-wire operation.

5. What is the data update frequency for this analog input module?
The Yokogawa SAI143-H63 has a data update frequency of 40 ms. This provides timely process monitoring for all 16 channels.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap