Product Attributes:

Manufacturer: Allen‑Bradley
Series: SLC 500
Part Number: 1746-OX8
Type: Digital Contact Output Module
Condition: In Stock
Origin: U.S.A
Weight: 0.35
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The Allen-Bradley 1746-OX8 is an SLC 500 digital contact output module. This module features 8 N.O. relay contact outputs that are individually isolated. It operates at 5-265V AC or 5-125V DC for flexibility. The Allen-Bradley 1746-OX8 is intended for high-current relay applications. Users trust this module for reliable switching in industrial control systems.


Technical Specifications

The 1746-OX8 delivers robust relay output performance with individual isolation. Below are the complete technical details.

General Specifications

  • Manufacturer: Rockwell Automation for industrial control reliability.

  • Brand: Allen-Bradley premium automation products.

  • Part Number: 1746-OX8 for precise identification.

  • Series: SLC 500 programmable controller family.

  • Module Type: Digital Contact Output Module.

  • Outputs: 8 N.O. relay contact outputs.

  • UPC: 10662073896620 for universal product identification.

Voltage and Current Ratings

  • Operating Voltage: 5-265V AC or 5-125V DC.

  • Current per Output (120V AC): 3 amps.

  • Current per Output (24V DC): 1.2 amps.

  • Minimum Load Current: 10 mA at 5V DC.

  • Maximum Off-State Leakage: 0 mA for complete isolation.

Relay Contact Ratings (AC)

  • Maximum Make/Break (120V AC): 30 A each.

  • Maximum Make (240V AC): 15 A.

  • Maximum Break (240V AC): 1.5 A.

  • Continuous Current (AC): 5 A for both voltages.

  • Make VA Rating: 3600 VA.

  • Break VA Rating: 360 VA.

Relay Contact Ratings (DC)

  • Maximum Make/Break (125V DC): 0.22 A each.

  • Maximum Make/Break (24V DC): 1.2 A each.

  • Continuous Current (125V DC): 1 A.

  • Continuous Current (24V DC): 2 A.

  • Make/Break VA Rating: 28 VA each.

  • Continuous VA Limit: 1440 VA maximum per module.

Backplane Current Consumption

  • At 5V DC: 85-90 milliamps (0.085-0.090 A).

  • At 24V DC: 90 milliamps (0.090 A).

  • Total Draw: Low consumption for 8 relay outputs.

Response Time and Step Response

  • Step Response (Input): 60 milliseconds.

  • Step Response (Output): 2.5 milliseconds.

  • Signal Delay (Resistive Load): 10 milliseconds for OFF and ON.

  • Switching Speed: Suitable for most industrial relay applications.

Isolation and Noise Immunity

  • Electro-Optical Isolation: 1500 Volts between I/O terminals and control logic.

  • NEMA Standard: ICS 2 to 230 noise immunity.

  • Individual Isolation: Each output is individually isolated.

Power Dissipation

  • Heat Dissipation per Point: 0.825 watts.

  • Minimum Dissipation: 2.590 Watts.

  • Total Dissipation: 8.60 Watts for the full module.

Environmental Specifications

  • Operating Temperature (Air Surrounding System): 0 to 60°C.

  • Storage Temperature: -40 to 85°C.

  • Operating Vibration (5-57 Hz): 0.015 inches peak displacement.

  • Operating Vibration (57-2000 Hz): 2.5 g acceleration.

  • Operating Shock: 10 g.

  • Enclosure Type: Open-type requiring installation in a cabinet.

Physical and Installation Specifications

  • Mounting: Chassis mount in SLC 500 rack.

  • Status Indicators: Available for output status monitoring.

  • Removal/Installation: Only when power is not applied to the chassis.

Application Suitability

  • Primary Application: Individually isolated, high-current relay applications.

  • Load Types: Resistive loads recommended.

  • Compatibility: SLC 500 system platform.


Installation Guide

Follow these steps to install the Allen-Bradley 1746-OX8 correctly.

  1. Power Down the Chassis: Turn off all power to the SLC 500 rack.

  2. Locate an Available Slot: Find an empty I/O slot in the chassis.

  3. Align the Module: Position the 1746-OX8 with the slot guides.

  4. Insert the Module: Slide it into the slot until firmly seated.

  5. Secure the Module: Tighten the mounting screws on the top and bottom.

  6. Wire Output Loads: Connect field devices to the N.O. relay terminals.

  7. Check Voltage Rating: Ensure AC loads are 5-265V or DC loads 5-125V.

  8. Verify Current Limits: Do not exceed 3A at 120V AC or 1.2A at 24V DC.

  9. Apply Power: Turn on the chassis power to the system.

  10. Monitor Status LEDs: Check output indicators for proper operation.

  11. Test Output Switching: Verify ON/OFF function with field devices.

  12. Measure Dissipation: Ensure total module dissipation stays below 8.60 Watts.

Installation Notes

  • Install or remove the module only when chassis power is off.

  • Individual output isolation allows mixing AC and DC loads on the same module.

  • Continuous current per module should be limited to 1440 VA.

  • The open-type enclosure requires installation in a protected cabinet.

  • Outputs are N.O. (normally open) relay contacts only.


Packaging List

This unit ships as a new and original product.

  • Allen-Bradley 1746-OX8 SLC 500 Digital Contact Output Module

  • Product data sheet with wiring diagram

  • Installation instructions

  • Anti-static factory packaging box


Frequently Asked Questions (FAQ)

1. Can I mix AC and DC loads on the same 1746-OX8 module?
Yes, the Allen-Bradley 1746-OX8 has individually isolated outputs. Each of the 8 N.O. relay contacts can switch different voltage types independently.

2. What is the maximum current rating per output on this module?
The 1746-OX8 provides 3 amps per output at 120V AC. At 24V DC, the maximum is 1.2 amps per output.

3. What is the backplane current consumption for this module?
The Allen-Bradley 1746-OX8 consumes 85-90 milliamps at 5V DC. It also draws 90 milliamps at 24V DC from the backplane.

4. What is the operating temperature range for the 1746-OX8?
The 1746-OX8 operates with an ambient air temperature of 0 to 60°C. Storage temperature ranges from -40 to 85°C.

5. Does this module have status indicators for each output?
Yes, the Allen-Bradley 1746-OX8 includes status indicators. These LEDs show the ON/OFF state of each relay output channel.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap