Introduction:

The Allen-Bradley 25A-D1P4N114 is a 0.4 kW, 380…480V AC three-phase PowerFlex 523 drive with IP20 protection and integral EMC filter.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen-Bradley
Part Number: 25A-D1P4N114
Type: AC adjustable-frequency drive — PowerFlex 523
Condition: In Stock
Origin: U.S.A
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

The Allen-Bradley 25A-D1P4N114 is a AC adjustable-frequency drive — PowerFlex 523 for industrial control and automation applications.

When a Small Pump Keeps Tripping on a Dirty Supply

Allen-Bradley 25A-D1P4N114 is a PowerFlex 523 AC adjustable-frequency drive rated 0.4 kW (0.5 HP) at 1.4 A, built for 380…480V AC three-phase input. A field engineer once faced a 0.5 HP transfer pump that tripped repeatedly on a weak rural feeder; the drive's published input voltage tolerance of -15 % / +10 % and 100 ms power ride-through address exactly that condition.

This Frame A unit carries an integral EMC filter, a standard interface module with keypad and LED display, and an integral brake IGBT. It belongs to the PowerFlex 520-series platform, where the 25A prefix identifies the PowerFlex 523 member.

Figure 1: Front view of the Allen-Bradley 25A-D1P4N114 AC adjustable-frequency drive — PowerFlex 523 showing its physical design and enclosure.

Key Specifications of the 25A-D1P4N114 Drive

  • Supply voltage: 380…480V AC, three-phase, with -15 % / +10 % tolerance.
  • Input frequency: 47…63 Hz.
  • Rated output: 0.4 kW (0.5 HP) normal duty and heavy duty, 1.4 A continuous.
  • Output frequency: 0…500 Hz programmable; output voltage 0 V to rated motor voltage.
  • Operating temperature: -20…+50 °C without derating in vertical IP20 mounting; up to +60 °C derated.
  • Efficiency: 97.5 % typical; displacement power factor 0.98 across the speed range.
  • Enclosure: IP20 NEMA/Open Type, panel mount; Frame A measures 152.0 H × 72.0 W × 172.0 D mm and weighs 1.1 kg.
  • Overload: heavy duty 150 % of rated current for 60 s and 180 % for 3 s.

The operating temperature window deserves attention in oil and gas service. Vertical IP20 mounting holds the full rating to +50 °C, while the optional 25-FANx-70C control module fan kit raises the maximum surrounding air temperature to 70 °C. Above +50 °C without that kit, the drive must be derated. Because the internal DC bus choke entry applies to the 11 kW (15 HP) class, this catalog number falls outside it.

How Does This unit Handle Power and Control I/O?

Input voltage tolerance and ride-through are the parameters that decide whether a small drive survives a marginal feeder. This unit rides through 100 ms power interruptions and holds logic control for 0.5 s minimum, 2 s typical. A DC bus overvoltage trip occurs at 810 V DC, and undervoltage trip at 390 V DC. Overcurrent protection trips at 200 % hardware limit and 300 % instantaneous fault.

Control I/O covers one dedicated Stop input plus four programmable digital inputs, one isolated analog input (0…10V DC or 4…20 mA, 10-bit), one programmable Form C relay output, and one non-isolated analog output. A pulse train input shares one programmable digital input at 0…100 kHz. Four independently programmable accel and decel times each span 0…600 s in 0.01 s increments.

Control methods are Volts/Hertz, sensorless vector control and Economizer SVC. Speed regulation reaches ±0.5 % across a 100:1 range in SVC mode. No encoder option is supported on the PowerFlex 523.

Communication and Integration Notes

The built-in port is one RS-485 DSI interface on the RJ45 terminal C1. Modbus RTU runs over that port with function codes 03, 06 and 16; data rate is selectable from 1200…38400 bit/s and node address from 1…247. Only pins 4 and 5 of the RJ45 connector carry the network, so other pins must not be connected. Termination resistors belong at each end of the cable, and network wiring should sit at least 0.3 m (1 ft) from power wires.

There is no embedded EtherNet/IP port on this model. Fieldbus connectivity requires an option card such as 25-COMM-E2P for EtherNet/IP, 25-COMM-D for DeviceNet, 25-COMM-P for PROFIBUS DP-V1 or 25-COMM-PNET2P for PROFINET. Wiring into such networks may require an external gateway or connection module; confirm cables and gateways with the supplier before commissioning.

Where Does This Drive Fit in Oil and Gas Operations?

Small metering pumps, lube-oil circulators and sample-transfer skids often sit on long feeders where voltage sags are routine. This unit suits those duties because its input tolerance and ride-through are published, not assumed. Its IP20 open-type enclosure belongs inside a control cabinet, and the integral EMC filter reduces the external filtering otherwise needed. Conformal coating complies with IEC 60721-3-3 level 3C2 for chemical and gases only, so the surrounding atmosphere must stay free of volatile or corrosive gases, vapors and dust.

For hazardous areas, note that no ATEX certificate is published for the PowerFlex 523; the ATEX row of the certification table applies to PowerFlex 525 drives only. The drive also has no embedded Safe Torque Off function.

Maintenance and Reliability Practices

Inspect the fan and heatsink periodically, since cooling is fan driven and airflow blockage shortens service life. Verify terminal torque and check the RS-485 termination at both cable ends after any network change. Monitor the drive's operating temperature against the ambient limits above, especially in summer. These parts are engineered for harsh oil and gas environments, and reliability you can depend on starts with disciplined inspection.

Frequently Asked Questions

What is the input voltage of the Allen-Bradley unit?

The Allen-Bradley unit accepts 380…480V AC three-phase input with a tolerance of -15 % / +10 % and an input frequency range of 47…63 Hz.

Can This unit run on single-phase input?

Yes, but a three-phase drive fed single-phase provides 35 % of its rating, so the 0.4 kW rating is not available in that configuration.

What is the operating temperature range of this drive?

In vertical IP20 mounting the drive operates from -20…+50 °C without derating, up to +60 °C derated, and up to +70 °C with the 25-FANx-70C control module fan kit.

Does This unit include an EtherNet/IP port?

No. The built-in port is RS-485 DSI; EtherNet/IP requires the 25-COMM-E2P option card.

What enclosure rating does this model carry?

This unit ships as IP20 NEMA/Open Type; IP30 / NEMA 1 / UL Type 1 requires the 25-JBAx option kit.

Contact PetroPartsOnline for parts suited to your application's requirements.

{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "25A-D1P4N114 | Allen-Bradley 0.4 kW PowerFlex 523 AC Drive", "mpn": "25A-D1P4N114", "sku": "25A-D1P4N114", "brand": {"@type": "Brand", "name": "Allen-Bradley"}, "description": "The Allen-Bradley 25A-D1P4N114 is a AC adjustable-frequency drive — PowerFlex 523 for industrial control and automation applications. When a Small Pump Keeps Tripping on a Dirty Supply Allen-Bradley 25A-D1P4N114 is a PowerFlex 523 AC adjustable-frequency drive rated 0.4 kW (0.5 HP) at 1.4 A, built for 380…480V AC three-phase input. A field engineer once faced a 0.5 HP transfer pump that tripped repeatedly on a weak rural feeder; the drive's published input voltage tolerance of -15 % / +10 % and ", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1793852298-25A-D1P4N114_1__fp59adf1a1.jpg"], "category": "Drives & Motion Control"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "How Does This unit Handle Power and Control I/O?", "acceptedAnswer": {"@type": "Answer", "text": "Input voltage tolerance and ride-through are the parameters that decide whether a small drive survives a marginal feeder. This unit rides through 100 ms power interruptions and holds logic control for 0.5 s minimum, 2 s typical. A DC bus overvoltage trip occurs at 810 V DC, and undervoltage trip at 390 V DC. Overcurrent protection trips at 200 % hardware limit and 300 % instantaneous fault. Control I/O covers one dedicated Stop input plus four programmable digital inputs, one isolated analog input (0…10V DC or 4…20 mA, 10-bit), one programmable Form C relay output, and one non-isolated analog output. A pulse train input shares one programmable digital input at 0…100 kHz. Four independently programmable accel and decel times each span 0…600 s in 0.01 s increments. Control methods are Volts/Hertz, sensorless vector control and Economizer SVC. Speed regulation reaches ±0.5 % across a 100:1 range in SVC mode. No encoder option is supported on the PowerFlex 523."}}, {"@type": "Question", "name": "Where Does This Drive Fit in Oil and Gas Operations?", "acceptedAnswer": {"@type": "Answer", "text": "Small metering pumps, lube-oil circulators and sample-transfer skids often sit on long feeders where voltage sags are routine. This unit suits those duties because its input tolerance and ride-through are published, not assumed. Its IP20 open-type enclosure belongs inside a control cabinet, and the integral EMC filter reduces the external filtering otherwise needed. Conformal coating complies with IEC 60721-3-3 level 3C2 for chemical and gases only, so the surrounding atmosphere must stay free of volatile or corrosive gases, vapors and dust. For hazardous areas, note that no ATEX certificate is published for the PowerFlex 523; the ATEX row of the certification table applies to PowerFlex 525 drives only. The drive also has no embedded Safe Torque Off function."}}, {"@type": "Question", "name": "What is the input voltage of the Allen-Bradley unit?", "acceptedAnswer": {"@type": "Answer", "text": "The Allen-Bradley unit accepts 380…480V AC three-phase input with a tolerance of -15 % / +10 % and an input frequency range of 47…63 Hz."}}, {"@type": "Question", "name": "Can This unit run on single-phase input?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, but a three-phase drive fed single-phase provides 35 % of its rating, so the 0.4 kW rating is not available in that configuration."}}, {"@type": "Question", "name": "What is the operating temperature range of this drive?", "acceptedAnswer": {"@type": "Answer", "text": "In vertical IP20 mounting the drive operates from -20…+50 °C without derating, up to +60 °C derated, and up to +70 °C with the 25-FANx-70C control module fan kit."}}, {"@type": "Question", "name": "Does This unit include an EtherNet/IP port?", "acceptedAnswer": {"@type": "Answer", "text": "No. The built-in port is RS-485 DSI; EtherNet/IP requires the 25-COMM-E2P option card."}}, {"@type": "Question", "name": "What enclosure rating does this model carry?", "acceptedAnswer": {"@type": "Answer", "text": "This unit ships as IP20 NEMA/Open Type; IP30 / NEMA 1 / UL Type 1 requires the 25-JBAx option kit. Contact PetroPartsOnline for parts suited to your application's requirements."}}]}]}

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap