Siemens 6ES7326-2BF10-0AB0 F-DO10x24V 2A PP Safety Output SIL3


Introduction:
The 6ES7326-2BF10-0AB0 is a fail-safe digital output module for SIMATIC S7F systems. It has 10 channels at 24V DC, 2A per channel.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Siemens 6ES7326-2BF10-0AB0 is a fail-safe digital output module for SIMATIC S7F systems. This module has 10 digital outputs. Each output provides 24V DC at 2 Amps. The module supports safety applications up to Category 4 (EN 954-1), SIL3 (IEC 61508), and PL e (ISO 13849-1). Diagnostic alarms help identify faults quickly. A 40-pin front connector connects field devices.
For inquiries, contact us at +86 158 8020 0923 (WhatsApp).
Part Number Breakdown (Tree Structure)
- 6ES7 → Product Family
- SIMATIC S7 series
- Siemens automation system
- 326 → Module Type
- Fail-safe digital output (F-DO)
- For S7F safety systems
- 2BF10 → Specific Model
- 10 digital outputs
- 24V DC, 2A per channel
- PP (positive switching)
- 0AB0 → Configuration Code
- Standard version
Key Specifications
- Brand: Siemens
- Part Number: Siemens 6ES7326-2BF10-0AB0
- Series: SIMATIC S7
- Module Type: Fail-safe Digital Output Module
- Number of Outputs: 10 digital outputs
- Output Voltage: 24V DC (signal “1” min L+ minus 1.0V)
- Output Current (Signal “1”): 2A rated (7mA to 2.4A range)
- Residual Current (Signal “0”): 0.5 mA maximum
- Short Circuit Protection: Yes
- Reverse Polarity Protection (1L+): Yes
Power Supply
- Supply Voltage 1L+: 24V DC nominal
- Load Voltage 2L+: 24V DC nominal (no reverse polarity protection)
- Load Voltage 3L+: 24V DC nominal (no reverse polarity protection)
- Current Draw 1L+: 100 mA maximum
- Current Draw 2L+ (no load): 100 mA maximum
- Current Draw 3L+ (no load): 100 mA maximum
- Backplane Bus Current (5V): 100 mA maximum
- Power Loss: 6 W typical
Switching Characteristics
- Lamp Load Power: 5 W maximum
- Switching Frequency (Resistive Load): 25 Hz maximum
- Switching Frequency (Inductive Load): 25 Hz maximum
- Switching Frequency (Lamp Load): 10 Hz maximum
Total Current per Group
Horizontal Installation:
- Up to 40°C: 10 A maximum
- Up to 60°C: 6 A maximum
Vertical Installation:
- Up to 40°C: 5 A maximum
Safety Certifications
- SIL (IEC 61508): SIL 3
- Category (EN 954-1): Category 4
- Performance Level (ISO 13849-1): PL e
- DIN VDE 0801: AK 5 and 6
- Fail-safe operation for SIMATIC S7F systems
Diagnostics and Status Information
- Diagnostic Alarm: Yes, supported
- Diagnostic Information: Readable via software
- Fail-safe Operation LED: Indicates safety status
- Group Error SF LED (Red): Indicates module fault
Potential Separation
- Between channels: Yes (groups of 5)
- Between channels and backplane bus: Yes
- Between channels and electronics power supply: Yes
- Isolation Test: 370V for 1 minute
Cable Length
- Shielded Cable: 1,000 meters maximum
- Unshielded Cable: 600 meters maximum
Connection Method
- Requires 40-pin front connector (not included)
- Order front connector separately for wiring
Physical Specifications
- Width: 40 mm
- Height: 125 mm
- Depth: 120 mm
- Weight: Approx. 330 g (0.33 kg)
Installation Guide
- Turn off all power before installation.
- Insert the Siemens 6ES7326-2BF10-0AB0 into an S7-300 rack slot.
- Press firmly until the module seats in the backplane.
- Secure the module with the retaining screws.
- Connect the 40-pin front connector for field wiring.
- Connect 24V DC supply to 1L+, 2L+, and 3L+ terminals.
- Wire output loads to the 10 output channels.
- Apply power and check LED indicators.
- Configure the module in STEP 7 safety program.
Wiring Notes
- 2L+ and 3L+ have no reverse polarity protection.
- Use external fuses for output protection if needed.
- Group outputs in groups of 5 for isolation.
- Use shielded cable for runs over 600 meters.
Maintenance Tips
- Check SF (group error) LED for fault indication.
- Monitor fail-safe operation LED for safety status.
- Read diagnostic information via STEP 7 software.
- Keep module free from dust and moisture.
- Ensure ambient temperature stays within limits.
Typical Applications
- Emergency shutdown systems (ESD)
- Burner management systems (BMS)
- Machine safety circuits (Category 4, PL e)
- Process safety applications (SIL3)
- Chemical and pharmaceutical safety systems
- Power plant safety controls
- High integrity industrial automation
Package Contents
- One Siemens 6ES7326-2BF10-0AB0 fail-safe digital output module
- Front connector not included (order separately)
Warranty and Shipping
- 12 months factory warranty from shipment date.
- Warranty covers manufacturing defects only.
- Overload or short circuit voids warranty.
- Shipping options: FedEx, UPS, DHL.
- Tracking number provided after shipment.
Frequently Asked Questions (FAQ)
Q1: What safety level does the 6ES7326-2BF10-0AB0 provide?
The Siemens 6ES7326-2BF10-0AB0 provides SIL3 (IEC 61508), Category 4 (EN 954-1), and PL e (ISO 13849-1). It meets DIN VDE 0801 AK 5 and 6 requirements. Use this module for high-integrity safety applications.
Q2: How many outputs does this module have?
This module has 10 fail-safe digital outputs. Each output provides 24V DC at 2A. Outputs group in two groups of 5 channels for isolation.
Q3: What is the maximum output current per channel?
Rated output current is 2A per channel. The permissible range is 7mA to 2.4A at 0-40°C. At 40-60°C, the same range applies with derating for group total.
Q4: Does this module have short-circuit protection?
Yes, the module has short-circuit protection on all outputs. It also has diagnostic alarms for fault detection. Read diagnostic information via STEP 7 software.
Q5: What front connector does the 6ES7326-2BF10-0AB0 need?
This module requires a 40-pin front connector. The connector is not included with the module. Order the front connector separately for wiring field devices.
Buying Guide
When you buy a Siemens 6ES7326-2BF10-0AB0 fail-safe output module, follow these tips. First, verify your safety requirement. This module meets SIL3, Cat.4, and PL e. Second, count your output channels. This module gives 10 channels. Third, check your current per output. Maximum is 2A at 24V DC. Fourth, consider derating for temperature. Total current drops at 60°C. Fifth, order the 40-pin front connector separately. Sixth, verify your system supports S7F safety functions. Seventh, check your cable length requirements. Shielded cable runs up to 1000 meters. Eighth, plan your group wiring. Outputs group in fives for isolation. Ninth, review warranty terms. We offer 12 months coverage. Tenth, choose your shipping method. We use FedEx, UPS, and DHL. Finally, test each output channel before connecting to safety-critical field devices.
Copyright © 2026 PLCDCS HUB Limited. All rights reserved.
Original Source: https://plcdcshub.com/
Partner: Powergear X Automation Limited
Oiltech Controls Limited