Siemens 6AR1303-0ED00-0AA0 PROFIBUS DP Ethernet Module


Introduction:
The 6AR1303-0ED00-0AA0 is a communication module from Siemens. It features PROFIBUS DP at 12 Mbit/s and Ethernet 10/100 Mbit/s for reliable industrial networking.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Siemens 6AR1303-0ED00-0AA0 is a specialized communication module. This device facilitates data exchange through both PROFIBUS DP and Ethernet connections.
The module achieves a high data transfer rate of 12 Mbit/s on PROFIBUS DP. Consequently, it ensures fast and reliable connectivity for industrial applications. Its compact, plug-in modular design simplifies installation in various setups. Therefore, this communication module suits a wide range of automation architectures.
General Specifications
The 6AR1303-0ED00-0AA0 offers robust communication capabilities for industrial networks.
Manufacturer: Siemens.
Product Type: Communication module with PROFIBUS DP and Ethernet interfaces.
Product Line: I/O Modules.
Part Number: 6AR1303-0ED00-0AA0.
UPC: 662643026108.
Installation Format: Compact, plug-in modular design.
Protocol Compliance: Supports PROFIBUS DP standards.
Communication Specifications
The 6AR1303-0ED00-0AA0 provides dual-network connectivity for maximum flexibility.
PROFIBUS DP Interface:
Data Transfer Rate: Up to 12 Mbit/s.
Protocol: PROFIBUS DP compliant.
Ethernet Interface:
Port Speed: 10/100 Mbit/s (Auto-negotiating).
Electrical Interface: RJ45 (8P8C) with Auto-MDI/MDIX.
Benefit: Convenient cabling without crossover cables.
Power and Electrical Specifications
The 6AR1303-0ED00-0AA0 operates efficiently on standard industrial power.
Power Requirements: 24 V DC supply.
Power Consumption: ≤2 W (under full load).
Electrical Isolation: Integrated signal protection.
Diagnostic Indicators: LED status lights for monitoring.
Environmental Specifications
The 6AR1303-0ED00-0AA0 withstands typical industrial conditions.
Operating Temperature Range: -20°C to +60°C.
Key Features
The 6AR1303-0ED00-0AA0 offers several advantages for industrial communication.
Dual Protocol Support:
The module supports both PROFIBUS DP and Ethernet standards. Therefore, it bridges legacy fieldbus networks with modern Ethernet systems.
High-Source Data Transfer:
PROFIBUS DP achieves up to 12 Mbit/s. Ethernet provides 10/100 Mbit/s auto-negotiating speeds. Consequently, data moves quickly and efficiently.
Compact Plug-In Design:
The modular format simplifies installation and replacement. Hence, it integrates easily into existing control cabinets.
Low Power Consumption:
Consumes only 2 W under full load. Thus, it adds minimal burden to the 24V DC power supply.
Integrated Electrical Isolation:
Provides signal protection against electrical disturbances. For this reason, the module operates reliably in noisy industrial environments.
LED Status Indicators:
Diagnostic LEDs convey operational information at a glance. As a result, troubleshooting is faster and easier.
Wide Operating Temperature:
Operates from -20°C to +60°C. Hence, it suits both indoor and sheltered outdoor installations.
Auto-MDI/MDIX Ethernet Port:
The RJ45 port automatically detects cable type. Therefore, straight-through or crossover cables work without configuration.
Typical Applications
The 6AR1303-0ED00-0AA0 suits various industrial communication needs.
Connecting PROFIBUS DP devices to Ethernet networks.
Gateway functionality between fieldbus and industrial Ethernet.
Data exchange in mixed-protocol automation systems.
Remote monitoring and control of PROFIBUS devices via Ethernet.
Upgrading legacy PROFIBUS systems with modern Ethernet connectivity.
Installation Guidelines
Install the 6AR1303-0ED00-0AA0 according to standard Siemens practices. First, ensure the 24V DC power supply is within specification. Then, insert the module into the designated slot in the rack or DIN rail.
Connect the PROFIBUS DP network to the appropriate port. Set the PROFIBUS address as required for your network. Next, connect the Ethernet cable to the RJ45 port. The Auto-MDI/MDIX feature accepts straight-through or crossover cables.
Power consumption is ≤2 W under full load. Therefore, the module adds minimal load to the power supply. The LED indicators will confirm proper operation after power-up.
What is in the Box
Please inspect all items upon delivery.
Siemens 6AR1303-0ED00-0AA0 communication module.
Installation instruction manual.
Anti-static protective bag.
Frequently Asked Questions (FAQ)
1. What communication protocols does the 6AR1303-0ED00-0AA0 support?
The 6AR1303-0ED00-0AA0 supports both PROFIBUS DP and Ethernet protocols. Therefore, it bridges these two industrial network types.
2. What is the data transfer rate on PROFIBUS DP?
The PROFIBUS DP interface on the 6AR1303-0ED00-0AA0 achieves up to 12 Mbit/s. This ensures fast and reliable fieldbus communication.
3. What is the power consumption of this module?
The 6AR1303-0ED00-0AA0 consumes ≤2 W under full load. It requires a 24V DC power supply.
4. Does this module provide electrical isolation?
Yes. The 6AR1303-0ED00-0AA0 includes integrated electrical isolation. Consequently, it protects against electrical disturbances and ground loops.
5. What is the operating temperature range of this module?
The 6AR1303-0ED00-0AA0 operates from -20°C to +60°C. Hence, it suits a wide range of industrial environments.