IC697CPU780 | GE 16 MHz Hot Standby CPU Module

Introduction:

The IC697CPU780 is a GE Series 90-70 single-slot CPU module with an 80386DX processor, 16 MHz clock, and hot standby redundancy for mission-critical PLC control.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: GE
Part Number: IC697CPU780
Type: CPU module
Condition: Subject to stock check
Shipping Port: Xiamen

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

What Is the GE IC697CPU780 CPU Module?

The GE this module is a single-slot CPU module from the Series 90-70 PLC platform, originally manufactured by GE Fanuc and now under Emerson Automation. It runs an embedded 80386DX microprocessor at 16 MHz and executes Boolean functions in 0.4 microseconds, making it a field-proven choice for hot standby control architectures.

This module is purpose-built for redundant controller configurations where high availability is mandatory. In a hot standby pair, a primary CPU synchronizes with a secondary CPU, and control switches automatically if the primary fails or transitions from RUN to STOP. The result is bumpless switching with no downtime.

Figure 1: Front view of the GE IC697CPU780 CPU module showing its physical design and enclosure.

Key Specifications at a Glance

  • Processor: 80386DX microprocessor
  • Clock speed: 16 megahertz
  • Boolean execution speed: 0.4 microseconds per boolean function
  • Input voltage: 5 Volts DC
  • Current draw: 1.6 Amps
  • Discrete I/O memory: 12 KB
  • Analog I/O memory: 8 KB
  • Maximum memory: 512 kilobytes
  • Communication port: RS485 interface
  • Battery: IC697ACC701 lithium battery
  • Module location: slot 1 of rack 0

How Does Hot Standby Redundancy Work?

Redundancy is the defining capability of this module. Two CPUs are required: one in the primary PLC and one in the secondary PLC. Each is configured separately, and communication between them is achieved through bus transmitter modules and redundancy communication modules.

Specific redundancy features include automatic CPU synchronization, online programming and online repair, one-scan switching, and configurable backup data size. A single point of failure is therefore eliminated in the control layer. The module also supports 20 milliseconds of scan extension, program and memory parity, and checksums.

Because the primary and secondary CPUs must be configured independently, commissioning requires careful planning. Engineers should verify that both units share identical program logic and memory configuration before placing the system into service.

Figure 2: Technical layout and connection details for the GE IC697CPU780 CPU module.

Power, Temperature, and Environmental Considerations

this module draws 1.6 Amps from the system bus and operates on a 5 Volts DC input voltage. These figures are critical when sizing the rack power supply and verifying backplane capacity. Under-voltage or unstable 5 Volts DC supply can cause intermittent faults, so the power source should be checked during routine maintenance.

Operating temperature is not specified in the available documentation. For detailed thermal limits and derating curves, refer to the official Series 90-70 datasheet or contact PetroPartsOnline for application-specific guidance.

The lithium battery (IC697ACC701) retains RAM data for up to six months and has a shelf life of 10 years at 20 degrees Celsius (68 degrees Fahrenheit). Battery replacement should be scheduled before the retention window expires to avoid memory loss during power cycles.

Where Is this module Used?

This CPU module is primarily deployed in hot standby CPU redundancy systems where continuous operation is essential. Typical environments include oil and gas processing facilities, pipeline control stations, and other mission-critical processes that cannot tolerate unplanned shutdowns.

Because the module is compatible with GE Fanuc Series 90-70 PLCs, it integrates into existing racks that follow the VME standard C.1. The single-slot form factor helps preserve rack space in dense configurations.

For projects requiring reliable sourcing of legacy GE Fanuc components, PetroPartsOnline offers application-specific selection guidance to match the CPU to your redundancy architecture.

Integration and Communication

this module includes an embedded RS485 communication port with a 15-pin D-connector. This port can interface with a programming computer for serial connections. The module also provides four status LED indicators: Module OK, RUN, Outputs enabled, and memory protect activated.

When integrating into a redundant system, bus transmitter modules and redundancy communication modules are required for primary-to-secondary communication. These components should be verified for compatibility with the existing Series 90-70 hardware.

Frequently Asked Questions

What is the input voltage requirement for this module?

The GE this module requires a 5 Volts DC input voltage and draws 1.6 Amps from the system bus. These values must be respected when sizing the rack power supply.

Can this module operate in a hot standby configuration?

Yes. The GE this module is specifically designed for hot standby operation, using two CPUs configured as primary and secondary. Automatic synchronization and bumpless switching ensure continuous control.

What is the battery life of this module?

The lithium battery, catalog number IC697ACC701, has a shelf life of 10 years at 20 degrees Celsius and retains data for up to six months. Periodic replacement is recommended to prevent memory loss.

How much memory does this module support?

The GE this module supports up to 512 kilobytes of system memory, with options including 128 KB, 256 KB, 256 KB with 256 KB non-volatile flash, or 512 KB total. It also provides 12 KB discrete I/O memory and 8 KB analog I/O memory.

What is the operating temperature range of this module?

Operating temperature specifications are not included in the available documentation. Please refer to the official GE Fanuc datasheet or contact PetroPartsOnline for thermal guidance.

Contact PetroPartsOnline for parts suited to your application’s requirements.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap