MTL5017 Isolated Barrier | Hazardous Area Relay


Introduction:
The MTL5017 controls two safe-area loads from hazardous area switches. It offers two relays with independent phase reversal. An automatic line fault detection (LFD) facility monitors each field circuit.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview: The MTL5017 Dual Relay Output Interface
The MTL5017 is a dual-channel relay output interface for hazardous area applications. It enables two safe-area loads to be controlled by two switches or proximity detectors in Zone 0, IIC, T6 hazardous areas. Therefore, this module provides two single-pole relay outputs for load control. Specifically, it includes an additional relay that signals line faults for either field circuit. As a result, system integrators choose this model when fault reporting is as important as load control.
Technical Specifications of the MTL5017
In addition to its dual-channel design, the MTL5017 offers independent phase reversal per channel. For example, you can configure each channel for normal or reverse phase operation separately. Furthermore, this module includes an automatic line fault detection (LFD) facility for each field circuit.
Core Parameters and Channel Specifications
Manufacturer: MTL
Part Number: MTL5017
Number of Channels: Two independent channels (highlighted in product catalog)
Location of Switches: Zone 0, IIC, T6 hazardous area; Div. 1, Group A
Location of Proximity Detectors: Zone 0, IIC, T4-6 with suitable certification
Safe-Area Output: Two relays with normally-open contacts (signal status of input)
Additional Output: One relay signals line faults (highlighted in product catalog)
Hazardous-Area Inputs: NAMUR/DIN 19234 compliant for proximity detectors
Voltage and Input Characteristics
Voltage Applied to Sensor: 7.0 to 9.0V from 1kΩ ±10%
Input/Output Hysteresis: 250µA typical
Response Time: 2ms maximum (highlighted in product catalog)
Input/Output Characteristics
Normal Phase: Output relay closed if Iin > 2.1mA or Rin < 2kΩ
Normal Phase: Output relay open if Iin < 1.2mA or Rin > 10kΩ
Reverse Phase: Output relay open if Iin > 2.1mA
Reverse Phase: Output relay closed if Iin < 1.2mA
Line Fault Detection (LFD) Specifications
Similarly, the MTL5017 provides automatic line fault monitoring for each channel. Consequently, a detected line fault opens the corresponding output relay and lights the red LED. In contrast to basic interfaces, this module uses a dedicated safe-area relay to signal fault conditions externally.
Open-Circuit Alarm: On if Iin < 100µA (highlighted in product catalog)
Open-Circuit Alarm: Off if Iin > 250µA
Short-Circuit Alarm: On if Rin < 100Ω (highlighted in product catalog)
Short-Circuit Alarm: Off if Rin > 360Ω
LFD Indication: Red LED per channel plus dedicated LFD relay
Line Fault Relay: Terminals 7 and 10 provide fault signaling
Required Resistors for LFD with Contact Input
Series Resistor: 500Ω to 1kΩ in series with the switch
Parallel Resistor: 20kΩ to 25kΩ in parallel with the switch
Phase Reversal Configuration
Phase Reversal: Independent on each channel (highlighted in product catalog)
User Selection: Selected by switches on the base of the unit
Relay Characteristics
Relay Type: Single-pole, normally-open contacts
Response Time: 2ms maximum (highlighted in product catalog)
Contact Rating (AC): 10VA, 45mA, 250V AC
Contact Rating (DC): 10W, 0.5A, 220V DC
Contact Life Expectancy: 10⁷ operations at maximum load
Note: Reactive loads must be adequately suppressed
Terminal Functions
Channel 1 Input: Terminal 1 (-), Terminal 2 (+)
Channel 2 Input: Terminal 4 (-), Terminal 5 (+)
Terminal 3: Earth leakage detection
Terminal 7: Line fault detection (LFD output)
Terminal 8: Output (channel 2)
Terminal 9: Output (channel 2)
Terminal 10: Line fault detection (LFD output)
Terminal 11: Output (channel 1)
Terminal 12: Output (channel 1)
Terminal 13: Supply negative (-)
Terminal 14: Supply positive (+)
LED Indicators on the MTL5017
Green LED: Power indication
Yellow LEDs: Two LEDs, one per channel (on when output relay is closed)
Red LEDs: Two LEDs, one per channel (on when line fault detected)
Power Specifications
Supply Voltage: 20 to 35V DC (highlighted in product catalog)
Current Consumption (at 24V): 50mA
Current Consumption (at 20V): 55mA
Current Consumption (at 35V): 40mA
Power Dissipation (at 24V): 1.1W (highlighted in product catalog)
Power Dissipation (at 35V): 1.25W
Isolation and Safety Description
Isolation: 250V AC or DC between circuits
Safety Description (Each Channel): 10.5V, 800Ω, 14mA, Um = 250V rms or DC
Installation Guide for the MTL5017 Dual Interface
Accordingly, proper installation ensures reliable operation of your MTL5017 in hazardous areas. Follow these steps to install it correctly. First, always disconnect all power sources before wiring the module. Next, mount the MTL5017 on a standard DIN rail in a safe-area enclosure. Then, connect the hazardous-area switches or proximity detectors to terminals 1/2 (Channel 1) and 4/5 (Channel 2). After that, wire the output relays to your loads using terminals 8/9 (Channel 2) and 11/12 (Channel 1). Finally, connect the line fault detection relay to terminals 7 and 10 for remote fault indication.
On the other hand, incorrect LFD resistor values will cause false fault alarms on either channel. For instance, omitting the parallel resistor may prevent open-circuit detection. Therefore, install the recommended 500Ω to 1kΩ series resistor and 20kΩ to 25kΩ parallel resistor for contact inputs. In addition, select the phase reversal switches on the base of the MTL5017 before powering up. Thus, you will achieve accurate line fault detection and proper output phasing.
For example, use a 1kΩ series resistor and 22kΩ parallel resistor for mechanical switches. Similarly, connect the LFD relay to your PLC input for centralized fault monitoring. As a result, the MTL5017 will correctly identify open and short circuit conditions while controlling your loads.
Packaging List for the MTL5017 Relay Output Interface
Specifically, your package for the MTL5017 includes the following items:
One MTL5017 dual-channel relay output interface module – highlighted
One product quick start guide with wiring diagram
One anti-static protective bag
Frequently Asked Questions (FAQ) About the MTL5017
Q1: What is the purpose of the additional line fault relay on the MTL5017?
A: The MTL5017 includes a dedicated LFD relay for remote fault reporting. Specifically, terminals 7 and 10 provide a contact closure when no fault exists. Consequently, this relay opens when either channel detects a line fault, allowing centralized alarm monitoring.
Q2: Can the MTL5017 be used with both switches and proximity detectors?
A: Yes, the MTL5017 accepts both mechanical switches and NAMUR proximity detectors. However, you must add external resistors when using switches with LFD enabled. Therefore, configure each channel independently based on your field device type.
Q3: What happens if a line fault is detected on only one channel of my MTL5017?
A: The MTL5017 handles each channel independently for output control. Specifically, a fault on Channel 1 opens only the Channel 1 output relay. However, the common LFD relay opens for any fault on either channel. Thus, one fault affects both the specific channel output and the global fault relay.
Q4: Is the MTL5017 compatible with 3-wire proximity sensors?
A: No, the MTL5017 is designed for 2-wire NAMUR proximity detectors only. In contrast, 3-wire sensors require different interface modules. Therefore, use 2-wire NAMUR compliant sensors with this module.
Q5: Why does my MTL5017 output relay not respond within 2ms?
A: The 2ms response time applies to the relay coil activation only. For instance, mechanical bounce and load characteristics add additional time. Therefore, measure response at the load rather than the relay coil for accurate verification. In addition, ensure your input signal transitions cleanly through the hysteresis thresholds.
Welcome to learn about our business. We are a leading global provider of automation equipment and will provide you with complete and cost-effective product solutions. You are welcome to choose us, and our services will make you a long-term partner like our other customers.
Now please let us know your needs and suggestions.
About Ubest
Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.
Product Center
Contact Us
Phone:+86 180 3000 5825
Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China
Email: [email protected]
Contact: Klaus