Introduction:

The MTL5017 controls two safe-area loads from hazardous area switches. It offers two relays with independent phase reversal. An automatic line fault detection (LFD) facility monitors each field circuit.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: MTL (Measurement Technology Ltd.)
Series: MTL5000 Series
Part Number: MTL5017
Type: Isolated Relay Interface
Condition: Subject to stock check
Weight: 0.35
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview: The MTL5017 Dual Relay Output Interface

The MTL5017 is a dual-channel relay output interface for hazardous area applications. It enables two safe-area loads to be controlled by two switches or proximity detectors in Zone 0, IIC, T6 hazardous areas. Therefore, this module provides two single-pole relay outputs for load control. Specifically, it includes an additional relay that signals line faults for either field circuit. As a result, system integrators choose this model when fault reporting is as important as load control.

Technical Specifications of the MTL5017

In addition to its dual-channel design, the MTL5017 offers independent phase reversal per channel. For example, you can configure each channel for normal or reverse phase operation separately. Furthermore, this module includes an automatic line fault detection (LFD) facility for each field circuit.

Core Parameters and Channel Specifications

  • Manufacturer: MTL

  • Part Number: MTL5017

  • Number of Channels: Two independent channels (highlighted in product catalog)

  • Location of Switches: Zone 0, IIC, T6 hazardous area; Div. 1, Group A

  • Location of Proximity Detectors: Zone 0, IIC, T4-6 with suitable certification

  • Safe-Area Output: Two relays with normally-open contacts (signal status of input)

  • Additional Output: One relay signals line faults (highlighted in product catalog)

  • Hazardous-Area Inputs: NAMUR/DIN 19234 compliant for proximity detectors

Voltage and Input Characteristics

  • Voltage Applied to Sensor: 7.0 to 9.0V from 1kΩ ±10%

  • Input/Output Hysteresis: 250µA typical

  • Response Time: 2ms maximum (highlighted in product catalog)

Input/Output Characteristics

  • Normal Phase: Output relay closed if Iin > 2.1mA or Rin < 2kΩ

  • Normal Phase: Output relay open if Iin < 1.2mA or Rin > 10kΩ

  • Reverse Phase: Output relay open if Iin > 2.1mA

  • Reverse Phase: Output relay closed if Iin < 1.2mA

Line Fault Detection (LFD) Specifications

Similarly, the MTL5017 provides automatic line fault monitoring for each channel. Consequently, a detected line fault opens the corresponding output relay and lights the red LED. In contrast to basic interfaces, this module uses a dedicated safe-area relay to signal fault conditions externally.

  • Open-Circuit Alarm: On if Iin < 100µA (highlighted in product catalog)

  • Open-Circuit Alarm: Off if Iin > 250µA

  • Short-Circuit Alarm: On if Rin < 100Ω (highlighted in product catalog)

  • Short-Circuit Alarm: Off if Rin > 360Ω

  • LFD Indication: Red LED per channel plus dedicated LFD relay

  • Line Fault Relay: Terminals 7 and 10 provide fault signaling

Required Resistors for LFD with Contact Input

  • Series Resistor: 500Ω to 1kΩ in series with the switch

  • Parallel Resistor: 20kΩ to 25kΩ in parallel with the switch

Phase Reversal Configuration

  • Phase Reversal: Independent on each channel (highlighted in product catalog)

  • User Selection: Selected by switches on the base of the unit

Relay Characteristics

  • Relay Type: Single-pole, normally-open contacts

  • Response Time: 2ms maximum (highlighted in product catalog)

  • Contact Rating (AC): 10VA, 45mA, 250V AC

  • Contact Rating (DC): 10W, 0.5A, 220V DC

  • Contact Life Expectancy: 10⁷ operations at maximum load

  • Note: Reactive loads must be adequately suppressed

Terminal Functions

  • Channel 1 Input: Terminal 1 (-), Terminal 2 (+)

  • Channel 2 Input: Terminal 4 (-), Terminal 5 (+)

  • Terminal 3: Earth leakage detection

  • Terminal 7: Line fault detection (LFD output)

  • Terminal 8: Output (channel 2)

  • Terminal 9: Output (channel 2)

  • Terminal 10: Line fault detection (LFD output)

  • Terminal 11: Output (channel 1)

  • Terminal 12: Output (channel 1)

  • Terminal 13: Supply negative (-)

  • Terminal 14: Supply positive (+)

LED Indicators on the MTL5017

  • Green LED: Power indication

  • Yellow LEDs: Two LEDs, one per channel (on when output relay is closed)

  • Red LEDs: Two LEDs, one per channel (on when line fault detected)

Power Specifications

  • Supply Voltage: 20 to 35V DC (highlighted in product catalog)

  • Current Consumption (at 24V): 50mA

  • Current Consumption (at 20V): 55mA

  • Current Consumption (at 35V): 40mA

  • Power Dissipation (at 24V): 1.1W (highlighted in product catalog)

  • Power Dissipation (at 35V): 1.25W

Isolation and Safety Description

  • Isolation: 250V AC or DC between circuits

  • Safety Description (Each Channel): 10.5V, 800Ω, 14mA, Um = 250V rms or DC

Installation Guide for the MTL5017 Dual Interface

Accordingly, proper installation ensures reliable operation of your MTL5017 in hazardous areas. Follow these steps to install it correctly. First, always disconnect all power sources before wiring the module. Next, mount the MTL5017 on a standard DIN rail in a safe-area enclosure. Then, connect the hazardous-area switches or proximity detectors to terminals 1/2 (Channel 1) and 4/5 (Channel 2). After that, wire the output relays to your loads using terminals 8/9 (Channel 2) and 11/12 (Channel 1). Finally, connect the line fault detection relay to terminals 7 and 10 for remote fault indication.

On the other hand, incorrect LFD resistor values will cause false fault alarms on either channel. For instance, omitting the parallel resistor may prevent open-circuit detection. Therefore, install the recommended 500Ω to 1kΩ series resistor and 20kΩ to 25kΩ parallel resistor for contact inputs. In addition, select the phase reversal switches on the base of the MTL5017 before powering up. Thus, you will achieve accurate line fault detection and proper output phasing.

For example, use a 1kΩ series resistor and 22kΩ parallel resistor for mechanical switches. Similarly, connect the LFD relay to your PLC input for centralized fault monitoring. As a result, the MTL5017 will correctly identify open and short circuit conditions while controlling your loads.

Packaging List for the MTL5017 Relay Output Interface

Specifically, your package for the MTL5017 includes the following items:

  • One MTL5017 dual-channel relay output interface module – highlighted

  • One product quick start guide with wiring diagram

  • One anti-static protective bag

Frequently Asked Questions (FAQ) About the MTL5017

Q1: What is the purpose of the additional line fault relay on the MTL5017?
A: The MTL5017 includes a dedicated LFD relay for remote fault reporting. Specifically, terminals 7 and 10 provide a contact closure when no fault exists. Consequently, this relay opens when either channel detects a line fault, allowing centralized alarm monitoring.

Q2: Can the MTL5017 be used with both switches and proximity detectors?
A: Yes, the MTL5017 accepts both mechanical switches and NAMUR proximity detectors. However, you must add external resistors when using switches with LFD enabled. Therefore, configure each channel independently based on your field device type.

Q3: What happens if a line fault is detected on only one channel of my MTL5017?
A: The MTL5017 handles each channel independently for output control. Specifically, a fault on Channel 1 opens only the Channel 1 output relay. However, the common LFD relay opens for any fault on either channel. Thus, one fault affects both the specific channel output and the global fault relay.

Q4: Is the MTL5017 compatible with 3-wire proximity sensors?
A: No, the MTL5017 is designed for 2-wire NAMUR proximity detectors only. In contrast, 3-wire sensors require different interface modules. Therefore, use 2-wire NAMUR compliant sensors with this module.

Q5: Why does my MTL5017 output relay not respond within 2ms?
A: The 2ms response time applies to the relay coil activation only. For instance, mechanical bounce and load characteristics add additional time. Therefore, measure response at the load rather than the relay coil for accurate verification. In addition, ensure your input signal transitions cleanly through the hysteresis thresholds.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap