MTL4032 Isolated Pulse Repeater 0-50kHz MTL4000 Series


Introduction:
The MTL4032 isolates pulses from hazardous area sensors. It supports NAMUR, switches, and pulse transmitters up to 50kHz.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The MTL MTL4032 isolates pulses from hazardous area sensors. It accepts switches, proximity detectors, or pulse transmitters. This unit handles high pulse rates with very fast response times. The MTL4032 is ideal for applications needing precise pulse counting. It fully floats the input channel for complete isolation. Users trust this device for Zone 0 and Div. 1 hazardous locations.
Technical Specifications
The MTL4032 delivers versatile pulse processing capabilities. Below are the complete technical details.
Input Specifications
Number of Channels: One fully floating channel for single sensor connection.
Sensor Type Options: Switch or proximity detector (NAMUR/DIN 19234).
Sensor Type Options (Continued): 2-wire or 3-wire voltage pulse transmitter.
Current pulse transmitter: Also supported by this model.
Hazardous Area Location (Switch): Rated for Zone 0, IIC, T6 hazardous area.
Hazardous Area Location (Switch): Also rated for Div. 1, Group A location.
Proximity Detector Location: Zone 0, IIC, T4 to T6 with suitable certification.
Switch and Proximity Input Details
Switch Input Logic: Output ON when switch is closed.
Switch Input Logic: Output OFF when switch is open.
Proximity Detector Excitation: Provides 7.0 to 9.0V DC from 1kΩ nominal.
Proximity Detector ON Condition: Output ON when input exceeds 2.1mA (below 2kΩ).
Proximity Detector OFF Condition: Output OFF when input drops below 1.2mA (above 10kΩ).
Switching Hysteresis: Nominal value is 0.2mA (approximately 650Ω).
Current and Voltage Pulse Input Details
Current Pulse Transmitter Supply: Provides 16.5V DC at 20mA.
Current Pulse Short Circuit Current: Maximum is 24mA.
Current Pulse ON Condition: Output ON when input exceeds 9.0mA.
Current Pulse OFF Condition: Output OFF when input drops below 7.0mA.
Current Pulse Hysteresis: Switching hysteresis is 0.5mA.
Voltage Pulse Input Impedance: Exceeds 10kΩ for minimal signal loading.
Voltage Switching Point (Vsp): Selectable at 3V, 6V, or 12V nominal.
Voltage Switch Location: Selector switch sits on top of the unit.
Voltage Pulse ON Condition: Output ON when input exceeds the selected Vsp.
Voltage Pulse OFF Condition: Output OFF when input drops below Vsp.
Voltage Switching Hysteresis: 100mV plus (0.1 x Vsp) typical.
Performance Specifications
Minimum Pulse Width (High): Only 10µs minimum for fast pulses.
Minimum Pulse Width (Low): Only 10µs minimum for narrow gaps.
Frequency Range: Operates from 0 to 50kHz for high-speed counting.
Response Time: Handles pulse rates up to 50,000 pulses per second.
Output Characteristics
Maximum Off-State Voltage: Rated at 35V for the output circuit.
Maximum Off-State Leakage Current: Only 10µA maximum when OFF.
Maximum On-State Voltage Drop: Calculated as 1 + (0.1 x current in mA) volts.
Maximum On-State Current: Rated at 50mA maximum.
Output Behavior on Power Failure: Output turns OFF if supply fails.
Output Protection: Zener diode protects against inductive loads.
LED Indicators
Amber LED: One amber LED indicates input status. It turns ON when the output circuit is ON.
Green LED: One green LED provides power indication.
Power Requirements
Current at 24V DC: Consumes 65mA during normal operation.
Current at 20V DC: Consumes 70mA at lower supply voltage.
Current at 35V DC: Consumes 55mA at higher supply voltage.
Power Dissipation (at 24V): Maximum 1.35W within the unit.
Power Dissipation (at 35V): Maximum 1.75W within the unit.
Terminal Assignments
Terminal 1: Common input negative (-).
Terminal 2: Switch or proximity detector input positive (+).
Terminal 3: Current pulse input positive (+).
Terminal 4: Transmitter supply positive (+).
Terminal 5: Voltage pulse input positive (+).
Terminal 7: Pulse output positive (+).
Terminal 8: Pulse output negative (-).
Terminal 13: Supply negative (-).
Terminal 14: Supply positive (+).
Isolation and Safety Parameters
Isolation Voltage: Rated at 250V AC between safe and hazardous area circuits.
Safety Description (Terminals 2 to 1): 10.5V, 800Ω, 14mA.
Safety Description (Terminals 4 to 3 and 1): 28V, 300Ω, 93mA.
Safety Description (Terminals 3 to 1): Non-energy storing apparatus at ≤1.2V, ≤0.1A, ≤20µJ, ≤25mW.
Safety Description (Terminals 5 to 4 and 1): Vmax ≤28V, Imax ≤94mA, Pmax ≤0.66W.
FM Entity Parameters
Terminals 1, 4, 5: Vt = 27.6V, It = 94mA, Ca = 0.12µF, La = 4.2mH.
Terminals 1, 2: Voc = 10.5V, Isc = 13mA, Ca = 2.4µF, La = 200mH.
Terminals 1, 3, 4: Vt = 27.6V, It = 155mA, Ca = 0.12µF, La = 1.57mH.
Terminals 1, 3: Voc = 1.1V, Isc = 51mA, Ca = 1000µF, La = 13.8mH.
Installation Guide
Follow these steps to install the MTL4032 correctly.
Mount the Unit: Clip the module onto a standard DIN-rail in a safe area.
Connect Power: Apply 20 to 35V DC to terminals 13 (negative) and 14 (positive).
Select Input Type: Choose switch, proximity, current, or voltage mode.
Set Voltage Switching Point: Use the top switch for 3V, 6V, or 12V if using voltage input.
Wire the Sensor: Connect the hazardous area sensor to the correct input terminals.
Wire the Output: Connect terminals 7 and 8 to your safe area controller or counter.
Verify LED Status: Check that the green LED turns ON. Test the amber LED with input signals.
Packaging List
This unit ships as a new and original product.
MTL4032 Pulse Isolator module (fully floating design)
Terminal number label strip
Product data sheet with connection diagrams
Anti-static factory packaging bag
Frequently Asked Questions (FAQ)
1. Can the MTL4032 accept signals from a NAMUR proximity detector?
Yes, the MTL4032 fully supports NAMUR proximity detectors per DIN 19234. The unit provides 8V excitation and senses current changes between 1.2mA and 2.1mA.
2. What is the maximum pulse frequency this isolator can handle?
The MTL4032 handles pulse frequencies from 0 to 50kHz. This supports very high-speed counting applications.
3. How do I select the switching voltage for a voltage pulse input?
Use the small selector switch on top of the MTL4032 unit. Choose 3V, 6V, or 12V based on your voltage pulse transmitter specifications.
4. Does the output turn ON or OFF if the power supply fails?
The output turns OFF when the power supply fails. This failsafe behavior protects downstream equipment from false signals.
5. What is the minimum pulse width the MTL4032 can detect?
The MTL4032 detects pulses with a minimum width of just 10µs for both high and low states. This ensures accurate counting of very short pulses.
Welcome to learn about our business. We are a leading global provider of automation equipment and will provide you with complete and cost-effective product solutions. You are welcome to choose us, and our services will make you a long-term partner like our other customers.
Now please let us know your needs and suggestions.
About Ubest
Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.
Product Center
Contact Us
Phone:+86 180 3000 5825
Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China
Email: [email protected]
Contact: Klaus
Industry Links
© 2026, Ubest Automation Limited All Rights Reserved. sitemap