Honeywell MIDAS-I-COS Sensor | Carbonyl Sulfide Detector


Introduction:
This Honeywell MIDAS S2 sensor detects Carbonyl Sulfide (COS). It uses reliable infrared technology for safety. The sensor offers a 5-year lifespan and precise 0-20ppm range.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview: The Smart Choice for COS Detection
The Honeywell Analytics MIDAS Sensor MIDAS S2 CARBONYL SULFIDE (COS) MIDAS-I-COS is a smart gas detector cartridge. Specifically, this unit uses advanced infrared sensor technology for stable readings. Therefore, you can use this sensor for workplace exposure monitoring. Consequently, the Honeywell MIDAS S2 provides accurate and fast gas detection.
Core Technical Specifications of the MIDAS S2 COS Sensor
For a clear understanding, this section lists all core technical parameters. First, the MIDAS Sensor MIDAS S2 measures Carbonyl Sulfide (COS) from 0 to 20ppm (blue text) . In addition, its resolution is 1ppm COS (blue text) . Furthermore, the sensor accuracy is ±10% of the measured value (blue text) . Meanwhile, default alarm 1 triggers at 5ppm. Similarly, default alarm 2 triggers at 10ppm. Also note that the LDL (Lowest Detectable Level) is 3ppm. Likewise, the LAL (Lowest Alarm Level) is 5ppm.
Regarding response speed, the T62.5 response time is typically 30 seconds. Moreover, the warm-up time takes less than 10 minutes. On the subject of longevity, the sensor cartridge life expectancy is 5 years. For operating conditions, the temperature ranges from 15°C to +35°C. Additionally, humidity tolerance is 0 to 90% non-condensing. Meanwhile, operating pressure must be 90 to 110kPa. For storage, the temperature range is +5°C to +25°C. Finally, the required calibration gas is COS at 10ppm.
Environmental Tolerance and Anti-Interference Data
Beyond basic parameters, the MIDAS-I-COS sensor operates reliably in stable lab conditions. However, performance may vary in real monitoring systems. Specifically, the effect of temperature on sensitivity is ±15% of measured value. Despite this, the sensor shows excellent resistance to interference gases. As a result, the cross-sensitivity table shows zero readings for many gases.
For instance, exposure to 3000ppm CO shows 0ppm COS reading (blue text) . Likewise, 5ppm H2S results in 0ppm COS reading. In the same way, 75ppm SO2 gives 0ppm COS reading. Moreover, 50ppm NO2 also gives 0ppm reading. Consequently, this high anti-interference ability makes the Honeywell MIDAS S2 very reliable. Thus, you can install it near other processes without false alarms.
Step-by-Step Installation Guidelines
To achieve optimal performance, always handle the MIDAS Sensor MIDAS S2 with clean gloves. First, avoid touching the internal optical surfaces. Next, insert the cartridge firmly into the Midas S2 gas monitor. Then, push until you hear a click sound. After that, the system will auto-detect the new sensor type. Subsequently, perform a full calibration after installation. For best results, use the recommended COS 10ppm calibration gas only. Also, allow the sensor to warm up for 10 minutes. Meanwhile, check the operating temperature is between 15°C to +35°C. Additionally, ensure humidity stays below 90% non-condensing. Finally, verify the pressure range is 90 to 110kPa before use.
Complete Package Contents
When you receive your unit, the box will include the following items:
One Honeywell Analytics MIDAS Sensor MIDAS S2 CARBONYL SULFIDE (COS) MIDAS-I-COS cartridge
One protective storage cap for the sensor
One desiccant pack for moisture control
One quick start reference card
One calibration certificate summary sheet
Frequently Asked Questions (FAQ)
Q1: How long does the MIDAS S2 COS sensor last?
A1: The Honeywell MIDAS S2 sensor cartridge lasts for 5 years. Therefore, store it between +5°C to +25°C for maximum life.
Q2: Can other gases cause a false reading on this sensor?
A2: No, they cannot. Specifically, the MIDAS-I-COS shows zero response to gases like H2S, SO2, CO, and NO2. Thus, this ensures very accurate COS detection.
Q3: What is the smallest gas change this sensor can see?
A3: The Honeywell Analytics MIDAS Sensor has a resolution of 1ppm COS. As a result, it can detect very small leaks quickly.
Q4: Does the sensor need a specific warm-up time?
A4: Yes, it does. For example, the MIDAS S2 requires less than 10 minutes warm-up time. Therefore, always wait before you trust the initial readings.
Q5: What accuracy can I expect from the MIDAS-I-COS?
A5: You get ±10% of the measured value accuracy. However, this applies under normal lab conditions from 20°C to 25°C.