SICK DT50-P2123 (Dx50 series) is a rugged, eye-safe laser distance sensor with 13m range, ±7mm accuracy, and -30°C to +65°C operation—built for demanding oil & gas environments.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: SICK
Part Number: DT50-P2123
Condition: Subject to stock check
Shipping Port: Xiamen

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

HDDM™ Laser Distance Sensing for Mission-Critical Oil & Gas Operations

In oil & gas facilities, reliable non-contact distance measurement is essential for level monitoring, positioning, and collision avoidance. The SICK DT50-P2123 (part number 1047399) from the Dx50 DT50 Hi series delivers field-proven performance using HDDM™ optical time-of-flight technology. With a measuring range up to 13,000 mm on natural objects, ±7 mm accuracy, and a visible Class 1 laser, this sensor is engineered for rugged, dependable service in demanding environments.

Figure 1: Front view of the SICK DT50-P2123 industrial automation component showing its physical design and enclosure.

Key Features & Technical Specifications

  • Measurement Principle: HDDM™ optical time-of-flight for high repeatability and ambient light stability.
  • Measuring Range: 200 mm to 13,000 mm (90% remission); 200 mm to 5,800 mm (18%); 200 mm to 3,400 mm (6%).
  • Repeatability: ≥ 1 mm; Measurement Accuracy: typ. ± 7 mm.
  • Light Source: Visible red laser diode (658 nm), Class 1 eye-safe per IEC 60825-1:2014.
  • Response Time: Fast 15 ms / Medium 30 ms / Slow 80 ms (averaging setting).
  • Supply Voltage: DC 10 V … 30 V, reverse-polarity protected.
  • Power Consumption: ≤ 2.1 W (without external load).
  • Outputs: 1x PNP digital (≤ 100 mA); 1x analog current (4–20 mA, ≤ 300 Ω, 16-bit); multifunctional input.
  • Electrical Connection: Male connector M12, 5-pin.
  • Operating Temperature: -30 °C to +65 °C (standard); up to +140 °C with cooling plates and filter.
  • Enclosure Protection: IP65 (EN 60529); Housing: Zinc die-cast (ZNAL4CU1) with PMMA window.
  • Dimensions / Weight: 36.1 x 62.7 x 57.7 mm; approx. 200 g.

The wide input voltage range and low power draw simplify integration into existing control cabinets, while the rugged zinc die-cast housing ensures reliability you can depend on in harsh oil & gas environments.

Failure Mode Analysis: Avoiding Common Pitfalls

Even robust sensors face challenges in oil & gas settings. Understanding potential failure modes helps maximize uptime:

  • Optical Contamination: Dust, oil mist, or debris on the PMMA window can attenuate the laser, reducing range or causing intermittent readings. Regular cleaning with a soft, lint-free cloth is recommended.
  • Temperature Extremes: Operating beyond -30 °C to +65 °C without cooling plates may lead to measurement drift or shutdown. For high-temperature zones, specify SICK cooling plates and protection filter to extend the range to +140 °C.
  • Electrical Noise: Although reverse-polarity protected, the analog output can be affected by ground loops. Use shielded cables and ensure proper grounding to maintain ±7 mm accuracy.
  • Laser Safety: Class 1 operation is eye-safe, but direct viewing of the beam should still be avoided. No additional safety measures are required under normal use.

By addressing these factors during installation and maintenance, operators can extend sensor life and reduce unplanned downtime.

Figure 2: Technical layout and connection details for the SICK DT50-P2123 industrial automation component.

Installation & Setup Best Practices

The DT50-P2123 is designed for straightforward integration. Mount the sensor using the M12 5-pin connector, ensuring the supply voltage is within 10–30 V DC. The multifunctional input allows configuration of response time (15/30/80 ms) to suit dynamic applications. For analog output, use a load resistor ≤ 300 Ω. The IP65 rating permits washdown and exposure to dust, but avoid direct high-pressure jets on the optical window. For high-temperature installations, mount cooling plates as specified in the datasheet.

Compatibility & Integration

With its PNP digital output and 4–20 mA analog interface, the DT50-P2123 integrates seamlessly with PLCs, DCS, and SCADA systems common in oil & gas. The M12 connector ensures secure, vibration-resistant connections. Integration Note: While the sensor does not include fieldbus protocols, wiring into PROFINET, EtherNet/IP, or DeviceNet networks may require an external gateway or connection module. Confirm cable and gateway compatibility with PetroPartsOnline.

Comparison with Similar Sensor Categories

  • Ultrasonic Sensors: Offer longer range but slower response and are affected by temperature and pressure; the DT50-P2123 provides faster, more precise laser measurement.
  • Inductive Proximity Sensors: Limited to short distances (<50 mm) and metal targets; the DT50-P2123 measures up to 13 m on natural surfaces.
  • Photoelectric Sensors: Typically used for presence detection; the DT50-P2123 adds analog distance output and higher accuracy.
  • Other Laser Distance Sensors: Many lack the rugged zinc die-cast housing and extended temperature options of the Dx50 series.

Frequently Asked Questions

Q: What is the maximum measuring range of the DT50-P2123?

A: Up to 13,000 mm on 90% remission targets; 5,800 mm on 18% and 3,400 mm on 6% remission surfaces.

Q: Can the sensor operate in high-temperature areas?

A: Standard range is -30 °C to +65 °C. With two cooling plates, it extends to +80 °C; with cooling plates and protection filter, up to +140 °C (Uv ≤ 24 V).

Q: What is the supply voltage and power consumption?

A: DC 10 V … 30 V, reverse-polarity protected; power consumption ≤ 2.1 W without external load.

Q: Is the laser Class 1 eye-safe?

A: Yes, Class 1 per IEC 60825-1:2014 and EN 60825-1:2014; no additional safety measures required.

Q: What output interfaces are available?

A: 1x PNP digital output (≤ 100 mA), 1x analog 4–20 mA current output (≤ 300 Ω, 16-bit), and a multifunctional input.

Product Support & Availability

The SICK DT50-P2123 is in stock and ready to ship from PetroPartsOnline. Our team provides application-specific selection guidance to ensure optimal performance in your oil & gas operation. Contact PetroPartsOnline for parts suited to your application’s requirements.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap