Allen-Bradley 1756-OA16I ControlLogix Output Module 16-Ch 120-240V


Introduction:
The 1756-OA16I is a 16-channel isolated AC output module for ControlLogix. It delivers 74-265V AC with 2A per point at 30°C.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Allen-Bradley 1756-OA16I is a discrete AC output module for ControlLogix systems. This module has 16 individually isolated output channels. It delivers 120V AC or 240V AC nominal output. The voltage range is 74 to 265V AC at 47-63 Hz. Each channel provides 2A continuous current at 30°C. The module uses removable terminal blocks for wiring connections.
For inquiries, contact us at +86 158 8020 0923 (WhatsApp).
Part Number Breakdown (Tree Structure)
- 1756 → Series Family
- ControlLogix platform
- Allen-Bradley / Rockwell Automation
- OA → Product Type
- AC Output module
- 16 → Channel Count
- 16 output channels
- I → Isolation Feature
- Individually isolated outputs
Key Specifications
- Brand: Allen-Bradley / Rockwell Automation
- Part Number: Allen-Bradley 1756-OA16I
- Series: 1756 ControlLogix
- Module Type: Digital AC Output Module
- Number of Outputs: 16 individually isolated outputs
- Nominal Output Voltage: 120/240 V AC
- Operating Voltage Range: 74 to 265 V AC
- Frequency Range: 47 to 63 Hz
Current Ratings (Per Point and Per Module)
Per Output Point:
- 2 Amps at 30°C (86°F)
- 1 Amp at 60°C (140°F)
- Linear derating between temperature points
Per Module (Total):
- 5 Amps at 30°C (86°F)
- 4 Amps at 60°C (140°F)
- Linear derating between temperature points
Output Delay Times
- OFF to ON at 60 Hz: 9.3 ms
- OFF to ON at 50 Hz: 11 ms
- ON to OFF at 60 Hz: 9.3 ms
- ON to OFF at 50 Hz: 11 ms
Additional Output Characteristics
- OFF State Leakage Current: 3 mA per point maximum
- Inrush Current: 20 A for 43 ms per point (repeat every 2 seconds at 60°C)
- Minimum Load Current per Point: 10 mA
- Peak ON Voltage Drop at 2A: 1.5V maximum
- Peak ON Voltage Drop at <50 mA: 6V maximum
Isolation and Protection
- Isolation Type: Basic insulation
- Isolation Voltage (Continuous): 250V
- Test Voltage: 1350V AC for 2 seconds
- Isolation applies to: outputs-to-backplane and output-to-output
- Internal Fusing: Not provided (add external fuses)
Configurable Fault Modes (Per Point)
- Hold last state
- ON (output turns on)
- OFF (output turns off – default)
Configurable Program Mode States (Per Point)
- Hold last state
- ON (output turns on)
- OFF (output turns off – default)
Power Consumption
- Backplane Current (5.1 VDC): 225 mA
- Backplane Current (5 VDC alternative): 300 mA
- Backplane Current (24 VDC): 3 mA (or 2.5 mA per some documentation)
- Power Dissipation at 60°C: 5.5 Watts maximum
- Thermal Dissipation: 18.76 BTU per hour
- Total Backplane Power: 1.59 Watts
Physical Specifications
- Slot Width: Single slot
- Enclosure Type: Open-style (none)
- Temperature Code: T4A
- RTB Keying: User-defined
Compatible Removable Terminal Blocks (RTB)
- 1756-TBCH (screw type)
- 1756-TBS6H (spring clamp type)
Compatible Chassis
- 1756-A4 (4-slot)
- 1756-A7 (7-slot)
- 1756-A10 (10-slot)
- 1756-A13 (13-slot)
- 1756-A17 (17-slot)
Installation Locations
- Local rack with ControlLogix controllers
- Remote I/O rack with 1756 communication adapter
- Any standard ControlLogix chassis slot
Environmental Specifications
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Relative Humidity: 5% to 95% non-condensing
- Maximum Operating Shock: 30G
- Storage Temperature: -40°C to 85°C
Installation Guide
- Turn off all power before installation.
- Insert the Allen-Bradley 1756-OA16I into any chassis slot.
- Press firmly until the module seats in the backplane.
- Secure the module with the retaining screws.
- Attach compatible RTB (1756-TBCH or 1756-TBS6H).
- Connect AC loads to the 16 output terminals.
- Add external fuses for overcurrent protection.
- Do not exceed per-point or per-module current ratings.
- Apply power and check module status LEDs.
- Configure fault and program modes in software.
Wiring Notes
- Use properly rated AC wiring for 265V maximum.
- Each output is individually isolated from others.
- No common connection between outputs.
- Follow local electrical codes for AC wiring.
- Use external circuit breakers or fuses for safety.
Derating Guidelines
- At 30°C: 2A per point, 5A total per module.
- At 60°C: 1A per point, 4A total per module.
- Linear derating applies between these temperatures.
- Reduce current when operating above 30°C.
- Ensure adequate ventilation around the module.
Maintenance Tips
- Check LED indicators for output status.
- Monitor ambient temperature around the module.
- Inspect terminal block connections for tightness.
- Test output channels annually with a dummy load.
- Keep module free from dust and moisture.
- Replace module if multiple outputs fail.
Package Contents
- One Allen-Bradley 1756-OA16I isolated AC output module
- One product label
- RTB not included (order 1756-TBCH or 1756-TBS6H separately)
Warranty and Shipping
- 12 months factory warranty from shipment date.
- Warranty covers manufacturing defects only.
- Overload or short circuit voids the warranty.
- Shipping options: FedEx, UPS, DHL.
- Tracking number provided after shipment.
Frequently Asked Questions (FAQ)
Q1: How many outputs does the 1756-OA16I have?
The Allen-Bradley 1756-OA16I has 16 individually isolated AC outputs. Each output channel is independent with its own isolation. This provides flexibility for different voltage sources per channel.
Q2: What voltage range does this module support?
The module supports 74 to 265V AC at 47-63 Hz. Nominal voltages are 120V AC and 240V AC. This covers most industrial AC control applications worldwide.
Q3: What is the maximum current per output point?
Maximum current is 2 Amps per point at 30°C. At 60°C, derate to 1 Amp per point. Total module current is 5 Amps at 30°C and 4 Amps at 60°C. Linear derating applies between temperatures.
Q4: Does the 1756-OA16I have internal fuses?
No, this module does not have internal fusing. You must add external fuses or circuit breakers. This protects your loads and the module from overcurrent damage.
Q5: What removable terminal blocks work with this module?
Use 1756-TBCH (screw clamp) or 1756-TBS6H (spring clamp) terminal blocks. Both provide reliable connections for field wiring. Order the RTB separately from the module.
Buying Guide
When you buy an Allen-Bradley 1756-OA16I isolated AC output module, follow these tips. First, count your AC output needs. This module gives 16 isolated channels. Second, verify your voltage matches the range (74-265V AC). Third, calculate your current per point. Do not exceed 2A at 30°C or 1A at 60°C. Fourth, calculate total module current. Do not exceed 5A at 30°C or 4A at 60°C. Fifth, consider your ambient temperature. Derate current above 30°C. Sixth, order removable terminal blocks. Choose 1756-TBCH or 1756-TBS6H. Seventh, add external fuses or breakers for protection. Eighth, verify your chassis has an available slot. Ninth, plan for fault mode configuration. Set outputs to hold, on, or off. Tenth, review warranty terms. We offer 12 months coverage. Eleventh, choose your shipping method. We use FedEx, UPS, and DHL. Finally, test each output channel with a dummy load before connecting expensive equipment.
Copyright © 2026 PLCDCS HUB Limited. All rights reserved.
Original Source: https://plcdcshub.com/
Partner: Powergear X Automation Limited
Oiltech Controls Limited