Allen-Bradley 1756-L81EK – ControlLogix Logix5580 Processor with Conformal Coating
The Allen-Bradley 1756-L81EK is a ControlLogix 5580 series standard controller. Specifically, this processor belongs to the Logix5580 family from Rockwell Automation. It features 3 MB of user memory for data and logic. Furthermore, it includes both USB 2.0 and 1GB Ethernet communication ports. In addition, this unit has a conformally coated board for enhanced environmental protection. Consequently, this processor suits demanding industrial automation applications requiring high performance and reliability.
Ordering Configuration and Product Identification
Manufacturer: Rockwell Automation.
Brand: Allen-Bradley.
Part Number: 1756-L81EK.
Series: ControlLogix 5580.
Module Type: ControlLogix Controller / Logix5580 Processor.
User Memory: 3 MB.
Maximum Digital I/O: 128,000.
Maximum Analog I/O: 4,000.
Maximum Total I/O: 128,000.
EtherNet/IP Devices Supported: 60 nodes.
EtherNet/IP Nodes (Alternative spec): Up to 100 nodes.
Programming Environment: Studio 5000 Automation Engineering & Design Environment.
Conformal Coating: Yes (EK suffix indicates coating).
Therefore, the Allen-Bradley 1756-L81EK offers robust memory capacity for complex applications.
Communication Ports and Networking
USB Port: USB 2.0 at 12 Mbps.
Ethernet Port: 1GB Ethernet port.
Supported Networks: EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, SynchLink.
Network Integration: Seamless connection to various industrial networks.
Programming Interface: USB for direct laptop connection.
High-Speed Communication: 1GB Ethernet for fast data exchange.
Third-party Support: Works with third-party process and device networks.
Thus, the 1756-L81EK offers versatile connectivity for modern industrial networks.
Controller Tasks and Program Capacity
Maximum Tasks: 32 tasks simultaneously.
Maximum Programs per Task: 1,000 programs.
Total Program Capacity: Up to 32,000 programs.
Event Tasks: All event triggers supported.
Task Types: Continuous, periodic, and event tasks.
Scheduling: Flexible task prioritization.
Performance: High-speed execution for time-critical applications.
Consequently, the Allen-Bradley 1756-L81EK handles extremely complex, multi-tasking applications.
Programming Languages
Function Block Diagram (FBD): Supported.
Ladder Diagram (LD): Supported.
Structured Text (ST): Supported.
Sequential Function Chart (SFC): Supported.
IEC 61131-3 Compliance: Yes.
Programming Software: Studio 5000 environment.
Flexibility: Multiple languages within the same project.
Code Reuse: User-defined function blocks and add-on instructions.
Therefore, the 1756-L81EK supports all major PLC programming languages for maximum flexibility.
Current Draw and Power Specifications
Current Draw (1.2 Volts DC): 5.0 milliamperes.
Current Draw (5.1 Volts DC): 1.20 milliamperes.
Power Dissipation: 6.2 Watts.
Thermal Dissipation: 21.2 BTU per hour.
Isolation Voltage (Continuous): 50 Volts.
Enclosure Type: None (open-style module).
Chassis Compatibility: Standard ControlLogix 1756 chassis.
Weight: Approximately 0.28 kg (0.62 lbs).
Form Factor: Single-slot module.
Thus, the 1756-L81EK consumes minimal power while delivering high performance.
Front Panel Display and LED Indicators
Display Type: 4-character alphanumeric display.
Display Function: Shows controller status and diagnostics.
OK LED: Solid green indicates normal operation.
OK LED (Red): Indicates power-up diagnostics or inoperable unit.
RUN LED: Glows green in normal operation mode.
RUN LED (Off): Indicates program mode or fault.
Status Monitoring: Quick visual diagnosis without software.
Display Information: Device status, operating mode, and fault codes.
Consequently, operators can monitor processor status at a glance.
Electronic Keying Protection
Electronic Keying: Supported.
Function: Cross-checks configured vs. installed hardware.
Protection Level: Prevents incorrect module installation.
Keying Options: Compatible, disabled, or exact match.
Safety: Reduces risk of damage from wrong module insertion.
Configuration: Set within Studio 5000 software.
Verification: Checks product code, revision, and series.
Therefore, the 1756-L81EK prevents hardware mismatches in critical systems.
Conformal Coating (EK Suffix)
Coating Type: Conformal coating on circuit board.
Purpose: Protects against moisture, dust, and chemicals.
Suffix Meaning: EK indicates conformally coated version.
Application: Harsh or corrosive environments.
Benefit: Extended product lifespan in demanding conditions.
Comparison: Standard version (without coating) for clean environments.
Industries: Chemical processing, marine, outdoor installations.
Thus, the Allen-Bradley 1756-L81EK suits harsh industrial environments.
Temperature and Environmental Ratings
Operating Temperature Range: 0°C to 60°C (32°F to 140°F).
Storage Temperature Range: -40°C to 85°C (-40°F to 185°F).
Relative Humidity: 5% to 95% non-condensing.
Vibration: 2G at 10 to 500 Hz.
Operating Shock: 30G rating.
Non-operating Shock: 50G rating.
Conformal Coating: Provides additional moisture protection.
Enclosure: Requires installation in ControlLogix chassis.
Moreover, the 1756-L81EK withstands typical industrial conditions with added coating protection.
Installation Guide
First, verify that all system power sources are completely disconnected. Then, select an available slot in your ControlLogix chassis. The 1756-L81EK occupies only a single slot. After that, slide the processor module into the chosen slot. Push firmly until the backplane connector is fully seated. The conformally coated board requires no special handling. Next, connect your Ethernet network to the 1GB Ethernet port. For programming, connect a USB cable to the USB 2.0 port (12 Mbps). Then, apply power to the ControlLogix chassis. The processor will begin its power-up sequence. The OK LED will glow red during diagnostics and then turn solid green when normal operation is achieved. Observe the 4-character alphanumeric display to confirm proper operation. After that, download your control program using Studio 5000 software. Select your preferred programming language (FBD, LD, ST, or SFC). Configure electronic keying protection for your I/O modules. Then, set up the appropriate communication networks (EtherNet/IP, ControlNet, DeviceNet, DH+, or RIO). Finally, test all I/O connections and communication paths thoroughly. As a result, the Allen-Bradley 1756-L81EK will provide reliable and high-performance control.
Packaging List
One Allen-Bradley 1756-L81EK ControlLogix Logix5580 processor module
One product identification label
One installation and configuration guide
Conformal coating (pre-applied to circuit board)
Common FAQs
Q1: How much user memory does the Allen-Bradley 1756-L81EK provide?
A: This processor provides 3 MB of user memory. It supports up to 128,000 digital I/O and 4,000 analog I/O. Therefore, it suits large-scale control applications.
Q2: What communication ports are on the 1756-L81EK?
A: This controller has a USB 2.0 port (12 Mbps) and a 1GB Ethernet port. It supports EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, and SynchLink networks. Consequently, it integrates into virtually any industrial network.
Q3: What does the EK suffix mean on the Allen-Bradley 1756-L81EK?
A: The EK suffix indicates the module has conformal coating. Therefore, it provides enhanced protection against moisture, dust, and chemicals. This version suits harsh or corrosive environments.
Q4: How many tasks and programs does the 1756-L81EK support?
A: This processor supports 32 tasks simultaneously. It supports up to 1,000 programs per task. Therefore, it handles extremely complex, multi-tasking applications.
Q5: What programming languages are available for the Allen-Bradley 1756-L81EK?
A: This controller supports Function Block Diagram (FBD), Ladder Diagram (LD), Structured Text (ST), and Sequential Function Chart (SFC). Therefore, it complies with IEC 61131-3 programming standards. Multiple languages can be used within the same project.