Introduction:

Allen-Bradley 1756-L72 ControlLogix Logix5572 processor. 4MB user memory, USB port, 128K digital I/O, 1GB SD card included.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen‑Bradley
Series: ControlLogix
Part Number: 1756-L72
Type: Processor Module (Logix5572)
Condition: Subject to stock check
Weight: 0.25
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Allen-Bradley 1756-L72 – ControlLogix Logix5572 Processor with 4MB Memory

The Allen-Bradley 1756-L72 is a ControlLogix Logix5572 processor. Specifically, this module belongs to the ControlLogix series from Rockwell Automation. It is a high-performance programmable automation controller (PAC). Furthermore, it features 4MB of user memory and 0.98MB of dedicated I/O memory. In addition, it includes a built-in USB communication port. Consequently, this processor suits large-scale control applications requiring extensive I/O and high-speed processing.

Ordering Configuration and Product Identification

  • Manufacturer: Rockwell Automation.

  • Brand: Allen-Bradley.

  • Part Number: 1756-L72.

  • Series: ControlLogix.

  • Module Type: Processor Module (Logix5572).

  • User Memory: 4 MB.

  • I/O Memory: 0.98 MB.

  • Maximum Digital I/O: 128,000.

  • Maximum Analog I/O: 4,000.

  • Redundancy Support: Full support.

  • UPC: 10612598876027.

  • UNSPSC: 32151705.

  • Therefore, the Allen-Bradley 1756-L72 offers substantial memory for complex applications.

Nonvolatile Memory and SD Card

  • Included SD Card: 1784-SD1 (1 GB) ships with every controller.

  • Upgrade Option: 1784-SD2 (2 GB) available.

  • Primary Use: Stores diagnostic data automatically during faults.

  • Troubleshooting: Data used by Rockwell Automation for analysis.

  • Recommendation: Only use Rockwell Automation SD cards.

  • Risk Warning: Other cards may cause data loss or corruption.

  • SD Card Installation: Recommended to keep installed at all times.

  • Additional Storage: Program backup and data logging.

  • Thus, the 1756-L72 provides reliable nonvolatile memory for fault diagnostics.

Capacitor Energy Storage Modules

  • Removable Module: 1756-ESMCAP / 1756-ESMCAPK (standard).

  • No Backup Module: 1756-ESMNSE / 1756-ESMNSEK (no WallClockTime backup).

  • Non-removable Module: 1756-ESMNRM / 1756-ESMNRMK.

  • Security Function: Prevents USB connection and SD card use.

  • Controller Types: Standard, no backup, and secure versions.

  • WallClockTime Backup: Maintained by capacitor storage.

  • Battery-Free Operation: No battery required for memory retention.

  • Therefore, the Allen-Bradley 1756-L72 eliminates battery replacement maintenance.

Current Draw and Power Specifications

  • Current Draw (1.2 Volts DC): 5 milliamps.

  • Current Draw (5.1 Volts DC): 800 milliamps.

  • Power Dissipation: 2.5 Watts.

  • Thermal Dissipation: 8.5 BTU per hour.

  • Isolation Voltage (Continuous): 30 Volts.

  • Isolation Test (Type Test): 500 Volts AC for 60 seconds.

  • Enclosure Type: None (open-style module).

  • Weight: 0.25 kg (0.55 lb).

  • Consequently, the 1756-L72 consumes minimal power and fits compactly.

USB Port Communication

  • USB Port Count: 1 port.

  • USB Version: USB 2.0, full speed.

  • Communication Speed: 12 Mbps.

  • Primary Functions: Programming, configuration, and online edits.

  • Advantage: More robust than RS-232.

  • Cable Cost: Does not require expensive communication cables.

  • RS-232 Replacement: Functions similarly but with better performance.

  • Supported Networks: EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, SynchLink, Third-party networks.

  • Thus, the Allen-Bradley 1756-L72 offers modern USB connectivity for programming.

Chassis Compatibility

  • 1756-A4: Compatible (4-slot).

  • 1756-A4K: Compatible (4-slot with coating).

  • 1756-A7: Compatible (7-slot).

  • 1756-A7K: Compatible (7-slot with coating).

  • 1756-A10: Compatible (10-slot).

  • 1756-A10K: Compatible (10-slot with coating).

  • 1756-A13: Compatible (13-slot).

  • 1756-A13K: Compatible (13-slot with coating).

  • 1756-A17: Compatible (17-slot).

  • 1756-A17K: Compatible (17-slot with coating).

  • Armor ControlLogix: Possible with specific modules.

  • Chassis Slot: Occupies only a single slot.

  • Attach/Detach: Easy module removal and insertion.

  • Therefore, the 1756-L72 fits all standard ControlLogix chassis.

Redundancy and Networking

  • Controller Redundancy: Supported with similar controller on same ControlNet network.

  • EtherNet/IP: Supported.

  • ControlNet: Supported (required for redundancy).

  • DeviceNet: Supported.

  • Data Highway Plus (DH+): Supported.

  • Remote I/O (RIO): Supported.

  • SynchLink: Supported for high-speed synchronization.

  • Third-Party Networks: Supported.

  • OPC UA Compliance: Yes, for easier configuration.

  • Network Integration: Seamless connection to control and data networks.

  • Consequently, the Allen-Bradley 1756-L72 integrates into virtually any industrial network.

Front Panel Display and Status

  • Display Type: 4-character alphanumeric display.

  • Displayed Information: Device status, operating mode, diagnostics.

  • Mode Selection: Changeable with supplied key.

  • Status Monitoring: Continuous prompts during operation.

  • Troubleshooting: Quick visual diagnosis without software.

  • Fault Indication: Clear error messages on display.

  • Thus, operators can monitor processor status at a glance.

Programming Languages

  • Relay Ladder: Supported.

  • Structured Text: Supported.

  • Function Block Diagram: Supported.

  • Sequential Function Chart (SFC): Supported.

  • Flexibility: Multiple languages within same project.

  • Code Reuse: User-defined function blocks.

  • Standard Compliance: IEC 61131-3 languages.

  • Therefore, the 1756-L72 supports all major PLC programming languages.

Temperature and Environmental Ratings

  • Operating Temperature Range: 0°C to 60°C (32°F to 140°F).

  • Storage Temperature Range: -40°C to 85°C (-40°F to 185°F).

  • Relative Humidity: 5% to 95% non-condensing.

  • Operating Vibration: 2G at 10 to 500 Hz.

  • Operating Shock: 30G rating.

  • Non-operating Shock: 50G rating.

  • Enclosure Rating: None (requires installation in enclosed chassis).

  • Chemical Resistance: Avoid direct exposure to harsh chemicals.

  • Moreover, the Allen-Bradley 1756-L72 withstands typical industrial environments.

Memory Upgrade and Flash Utility

  • Memory Type: Integrated memory.

  • Upgrade Method: Flash utility tool.

  • Downgrade Method: Flash utility tool.

  • Flexibility: Change memory configuration as needed.

  • Firmware Updates: Supported via USB.

  • Version Control: Manage multiple firmware revisions.

  • Compatibility: Ensure matching firmware for I/O modules.

  • Consequently, the 1756-L72 adapts to changing application requirements.

Installation Guide

First, verify that all system power sources are completely disconnected. Then, select an available slot in your ControlLogix chassis. The Allen-Bradley 1756-L72 occupies only a single slot. After that, slide the processor module into the chosen slot. Push firmly until the backplane connector is fully seated. Next, install the included 1784-SD1 (1GB) SD card into the SD card slot. Rockwell Automation recommends using only their certified SD cards. Then, connect your USB programming device to the USB 2.0 port. Use a standard USB cable for programming, configuration, and online edits. After that, apply power to the ControlLogix chassis. The processor will begin its power-up sequence. Observe the 4-character alphanumeric display to confirm proper operation. For redundant configurations, pair this controller with an identical unit on the same ControlNet network. Then, download your control program using Studio 5000 software. Select your preferred programming language (relay ladder, structured text, function block, or SFC). Configure the appropriate communication networks (EtherNet/IP, ControlNet, DeviceNet, DH+, or RIO). Finally, test all I/O connections and communication paths thoroughly. As a result, the Allen-Bradley 1756-L72 will provide reliable and high-performance control.

Packaging List

  • One Allen-Bradley 1756-L72 ControlLogix Logix5572 processor module

  • One 1784-SD1 1GB SD card (installed or included)

  • One set of capacitor energy storage modules (installed)

  • One product identification label

  • One installation and configuration guide

  • One mode selection key

Common FAQs

Q1: How much memory does the Allen-Bradley 1756-L72 provide?
A: This processor provides 4 MB of user memory. It also provides 0.98 MB of dedicated I/O memory. Therefore, it supports 128,000 digital I/O and 4,000 analog I/O.

Q2: Does the 1756-L72 require a battery for memory backup?
A: No, this processor does not use batteries. Instead, it uses capacitor energy storage modules. Consequently, battery replacement maintenance is eliminated entirely.

Q3: What SD card is included with the Allen-Bradley 1756-L72?
A: The 1784-SD1 1GB SD card ships with every controller. You can upgrade to 2GB using the 1784-SD2 card. Therefore, only use Rockwell Automation certified SD cards to prevent data loss.

Q4: What communication port does the 1756-L72 have?
A: This processor has one USB 2.0 full-speed port (12 Mbps). It replaces the traditional RS-232 port found on older controllers. Consequently, programming and configuration use standard USB cables.

Q5: What programming languages does the Allen-Bradley 1756-L72 support?
A: This processor supports relay ladder, structured text, function block, and sequential function chart (SFC). Therefore, it complies with IEC 61131-3 programming standards. Multiple languages can be used within the same project.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap