The Allen-Bradley 1756-L71S is a GuardLogix 5570 controller from the Logix5000 family. This controller combines standard ControlLogix features with additional safety functions. The 1756-L71S uses a dual-processor solution requiring a 1756-L7SP safety partner module. Together, they achieve SIL 3 or Cat. 4/PLe safety standards. The safety partner controller configures automatically for major benefit. User memory reaches 2 MB for standard logic and data. Safety memory adds 1 MB for safety-related tasks. I/O memory measures 0.98 MB for I/O image handling. A 1 GB non-volatile memory SD card (1784-SD1) ships with the controller. This card can upgrade to 2 GB using the 1784-SD2. For diagnostics, the controller features an onboard 4-character alphanumeric display. The Allen-Bradley 1756-L71S installs in any slot of a ControlLogix 1756 chassis. Controller redundancy is not supported on this model.
Technical Specifications
General Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1756-L71S |
| Series | GuardLogix 5570 |
| Module Type | Processor Module |
| Product Type | Programmable Automation Controller |
| UPC | 10885630016464 |
| Enclosure | None (Open-Style) |
| Weight | 0.55 lbs (approx. 0.25 kg) |
Memory Specifications
| Parameter | Value |
|---|---|
| User Memory | 2 MB |
| Safety Memory | 1 MB |
| I/O Memory | 0.98 MB |
| Non-volatile Memory | 1 GB (1784-SD1 ships with controller, upgradable to 2 GB with 1784-SD2) |
I/O Capacity Specifications
| Parameter | Value |
|---|---|
| Maximum I/O | 128,000 |
| Maximum Digital I/O | 128,000 |
| Maximum Analog I/O | 4,000 |
Task & Program Specifications
| Parameter | Value |
|---|---|
| Number of Standard Tasks | 31 |
| Number of Safety Tasks | 1 |
| Programs per Task | 100 programs |
| Event Tasks | All triggers |
Power Specifications
| Parameter | Value |
|---|---|
| Current Draw (1.2 Volts DC) | 5 milliamperes |
| Current Draw (5.1 Volts DC) | 800 milliamperes |
| Power Dissipation | 2.5 Watts |
| Thermal Dissipation | 8.5 BTU per hour |
| Isolation Voltage | 30 Volts Continuous (Basic Insulation Type) |
Communication Specifications
| Parameter | Value |
|---|---|
| Built-in Communication | 1 USB port (full speed) |
| Optional Communication Adapters | EtherNet/IP, ControlNet, DeviceNet |
| Maximum Controller Connections | 500 |
Redundancy & Safety Specifications
| Parameter | Value |
|---|---|
| Redundancy | Not supported |
| Safety Partner Requirement | 1756-L7SP safety module required |
| Safety Standards | SIL 3, Cat. 4/PLe |
Dual-Processor Safety Architecture
The 1756-L71S uses a dual-processor solution for safety functions. A 1756-L7SP safety partner module must be used alongside this controller. The safety partner configures automatically, providing a single project for both standard and safety logic. Together, they meet SIL 3 or Cat. 4/PLe safety standards. For safety communication, the Allen-Bradley 1756-L71S supports Ethernet/IP, ControlNet, and DeviceNet networks. Safety functions are communicated from the primary controller to the partner safety controller.
Memory Configuration
User memory reaches 2 MB for standard control applications. Safety memory adds 1 MB exclusively for safety-related tasks. I/O memory measures 0.98 MB for I/O image and data tables. A 1 GB Secure Digital card (1784-SD1) ships pre-installed with the controller. This non-volatile memory stores diagnostic data and application backups. Rockwell Automation uses this diagnostic data when troubleshooting controller issues. Use only Rockwell Automation SD cards, as other cards may cause data corruption. The Allen-Bradley 1756-L71S supports upgrade to 2 GB using the 1784-SD2 card. The SD card must remain installed because diagnostic data saves to this location.
I/O Capacity
The 1756-L71S handles up to 128,000 discrete I/O points maximum. Analog I/O capacity reaches 4,000 points. This high I/O capacity suits large control systems with distributed I/O. The controller controls or monitors I/O over the backplane or through I/O links. For scalable system design, the Allen-Bradley 1756-L71S provides ample I/O addressing space.
Onboard Display
A 4-character alphanumeric display is onboard the 1756-L71S controller. This display enables easy monitoring of runtime information. Controller diagnostics are also visible through this display. For troubleshooting, the display provides immediate status without a programming terminal. The Allen-Bradley 1756-L71S reduces diagnostic time with front-panel visibility.
USB Port
One USB port with full speed provides built-in communication capability. This port supports programming, hardware configuration, and online editing. For local access, the USB port eliminates the need for network adapters. The Allen-Bradley 1756-L71S simplifies laptop-to-controller connections during commissioning.
Energy Storage
The 1756-L71S uses capacitor modules for energy storage instead of lithium batteries. Three different capacitor modules are available. Two are removable for service flexibility. The non-removable 1756-ESMNRM or 1756-ESMNRMK module secures the controller by preventing USB connections. For battery-free operation, the Allen-Bradley 1756-L71S eliminates battery replacement maintenance.
Standard & Safety Functions
Standard functions include I/O control, logic execution, timing, and counting. Report generation, communication, arithmetic computations, and data file manipulation are also supported. Safety functions are communicated by the primary controller to the partner safety controller. For programming, the Allen-Bradley 1756-L71S supports Relay Ladder Logic (RLL), Structured Text, Function Block Diagram, and Sequential Function Chart (SFC). However, only Relay Ladder Logic is permitted for programming safety tasks.
Optional Communication Adapters
The 1756-L71S supports EtherNet/IP, ControlNet, and DeviceNet adapters. For Ethernet, using 1756-EN2x allows 256 EtherNet/IP connections and 128 TCP connections. Using 1756-ENBT allows 128 EtherNet/IP connections and 64 TCP connections. For ControlNet, using 1756-CN2/A supports 100 ControlNet connections. Using 1756-CNB/D or 1756-CNB/E supports 40 connections. Using 1756-CN2/B supports 128 connections. For flexible networking, the Allen-Bradley 1756-L71S adapts to various communication architectures.
Chassis Compatibility
The 1756-L71S installs in any slot of ControlLogix 1756 chassis. Compatible chassis include 1756-A10K, 1756-A4K, 1756-A4, 1756-A7K, 1756-A7, 1756-A17, 1756-A10, 1756-A13, 1756-A17K, and 1756-A13K. For system integration, the Allen-Bradley 1756-L71S fits standard ControlLogix form factors.
Installation Guidelines
Follow these steps for proper installation of the 1756-L71S.
Power down the ControlLogix chassis completely before installation.
Select any slot in the 1756 chassis for the controller (redundancy not supported).
Install the 1756-L7SP safety partner in an adjacent slot.
Align the 1756-L71S with the upper and lower card guides.
Slide the module firmly into place until backplane connectors engage.
Secure the module using the retaining screws at top and bottom.
Insert the 1784-SD1 SD card (or upgraded 1784-SD2) into the slot.
Connect USB cable to the onboard USB port for programming.
Install optional communication adapters as needed (EtherNet/IP, ControlNet, DeviceNet).
Power up the system and verify the display shows normal operation.
Note: The 1756-L71S requires a 1756-L7SP safety partner module to achieve SIL 3 or Cat. 4/PLe ratings. Use only Rockwell Automation SD cards to prevent data corruption. The SD card must remain installed for diagnostic data collection. Controller redundancy is not supported on this model.
Packaging List
One Allen-Bradley 1756-L71S GuardLogix 5570 Controller
One 1784-SD1 (1 GB) Secure Digital card (pre-installed)
One product installation manual
One anti-static protective bag
Common FAQs
1. What is the memory configuration of the 1756-L71S?
User memory reaches 2 MB for standard logic and data. Safety memory adds 1 MB for safety-related tasks. I/O memory measures 0.98 MB for I/O image handling. A 1 GB non-volatile memory SD card (1784-SD1) ships with the controller. The Allen-Bradley 1756-L71S provides comprehensive memory for mixed standard and safety applications.
2. Does the 1756-L71S require a safety partner?
Yes, this controller requires a 1756-L7SP safety partner module. Together they form a dual-processor solution meeting SIL 3 or Cat. 4/PLe safety standards. The safety partner configures automatically for major benefit. For safety applications, the Allen-Bradley 1756-L71S must be used with its safety partner.
3. What is the maximum I/O capacity of the 1756-L71S?
The controller handles up to 128,000 discrete I/O points maximum. Analog I/O capacity reaches 4,000 points. This high I/O capacity suits large control systems with distributed I/O. For scalable system design, the Allen-Bradley 1756-L71S provides ample I/O addressing space.
4. Does the 1756-L71S support controller redundancy?
No, controller redundancy is not supported on this model. For redundancy applications, consider other ControlLogix controllers. The Allen-Bradley 1756-L71S focuses on safety functionality rather than redundancy.
5. What programming languages work with the 1756-L71S?
Supported languages include Relay Ladder Logic (RLL), Structured Text, Function Block Diagram, and Sequential Function Chart (SFC). However, only Relay Ladder Logic is permitted for programming safety tasks. For flexible programming, the Allen-Bradley 1756-L71S supports multiple standard languages plus RLL for safety.
Why Choose This Safety Controller?
The Allen-Bradley 1756-L71S delivers integrated standard and safety control in a single package. Dual-processor architecture with 1756-L7SP achieves SIL 3 or Cat. 4/PLe ratings. Two MB user memory plus 1 MB safety memory handles complex applications. High I/O capacity of 128,000 points suits large distributed systems. USB port simplifies programming and diagnostics. Capacitor-based energy storage eliminates battery maintenance. For GuardLogix applications requiring SIL 3 safety, choose the 1756-L71S.