Allen-Bradley 1746-P2 Power Supply SLC 500 120/220V


Introduction:
The 1746-P2 is a power supply for Allen-Bradley SLC 500 systems. It accepts 120/220V AC input and provides 5A at 5V DC and 0.96A at 24V DC.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Allen-Bradley 1746-P2 is a modular power supply for the SLC 500 automation platform. This power supply is installed in the leftmost slot of the SLC chassis. Notably, its installation location is not included in the slot count; slot counting starts with Slot Zero (0) for the PLC processor or communication adapter.
The power supply accepts nominal input voltages of 120/220 Volts AC. Furthermore, it provides internal DC power to the backplane and user power to field devices. Therefore, this module is essential for any SLC 500 system.
General Specifications
The 1746-P2 offers robust power delivery for SLC 500 systems.
Manufacturer: Rockwell Automation.
Brand: Allen-Bradley.
Part Number: 1746-P2.
Series: SLC 500.
Module Type: Power Supply.
Input Power: 70 Watts.
Input Voltage: 120 to 220 Volts AC (85-132 or 170-265V AC range).
Frequency: 47 to 63 Hertz.
Typical Line Power Requirement: 180 VA.
Inrush Current: 20 Amps maximum.
Location: 1746 Chassis (leftmost slot).
Weight: 1.1 kg (2.5 lbs).
Dimensions: 5.5 x 3.3 x 5.7 inches.
Operating Temperature: 0 to 60°C.
Internal Current Capacity (Backplane)
The 1746-P2 supplies DC power to the SLC 500 backplane.
Backplane Current (5 Volts): 5 Amps.
Backplane Current (24 Volts): 0.46 Amps.
Therefore, the module provides 5A at 5V DC and 0.96A at 24V DC internal capacity.
User Power Current Capacity
The 1746-P2 also provides user power for field devices.
User-Power Current Capacity (24V DC): 200 mA.
User-Power Voltage Range: 18 to 30 Volts DC.
Consequently, it can power small field loads directly without an external power supply.
Output Voltage and Protection
The 1746-P2 includes built-in protection features.
Output Voltage Range: 18 to 30 Volts DC.
Fuse Protection: 1746-F1 or equivalent (internal fuse).
Maximum User-Supplied Overcurrent Protection: 15 A.
The internal fuse guards against fire hazards due to short-circuit conditions. For this reason, the module meets safety requirements.
Isolation Rating
The 1746-P2 provides isolation between input and backplane.
Input Terminal and Backplane Isolation: 1800V AC RMS for 1 second.
Thus, the backplane is protected from input power line disturbances.
CPU Hold-Up Time
The 1746-P2 features a hold-up time that keeps the processor running during power disturbances.
Hold-Up Time (full load): 20 ms.
Hold-Up Time (no load): 3000 ms.
Therefore, the PLC processor continues functioning even when input voltage falls below the nominal level for short periods.
Undervoltage Operation
When undervoltage operation occurs, the 1746-P2 will continue to power the SLC 500 controllers for a short period. However, if the input voltage remains below the recommended range longer than the CPU hold-up time, the controllers will turn off. Consequently, operation resumes automatically only when the power supply receives the recommended input voltage.
Overcurrent Behavior by Series
The 1746-P2 behaves differently depending on the series revision.
Series A and B: Power supply shutdown and CPU fault occur. Recovery procedure: reload the user program.
Series C: 24V DC user shutdown occurs, but the CPU continues its operation. Recovery procedure: correct the overcurrent condition.
Thus, check your module series for the appropriate fault response.
Input Voltage Configuration
The 1746-P2 has jumper pins to set the correct input voltage.
Jumper Setting: 100/120 VAC or 200/240 VAC.
Therefore, configure the jumper correctly before applying power.
Terminal Connections
When the front cover is opened, the 1746-P2 front panel is exposed. It has five (5) terminals:
AC line connection terminals.
DC power connection terminals.
One ground terminal.
Two AWG wires maximum per terminal are permitted.
Safety Warnings
The 1746-P2 requires careful handling during installation.
Avoid Electrical Arc: Disconnecting or connecting a wire with active supply may produce an electric arc which may damage the electronic backplane.
Perform Operations When Power Is Inactive: Essential for safety and equipment protection.
Voltage Surge Sensitivity: The power supply module is sensitive to voltage surges that may occur when starting high-inductive electrical loads. To avoid damage, an isolation transformer may be installed.
Enclosure Type
The 1746-P2 has an open-type enclosure. Consequently, it must be installed inside a suitable control cabinet.
Key Features
The 1746-P2 offers several advantages for SLC 500 power applications.
Dual Input Voltage Range:
Accepts 120/220V AC nominal (85-132V or 170-265V range). Therefore, it suits global power systems.
High Backplane Current Capacity:
Provides 5A at 5V DC and 0.96A at 24V DC. Hence, it supports large SLC 500 chassis configurations.
Integrated User Power:
Offers 200 mA at 24V DC for field devices. Consequently, small loads may not need an external supply.
Fuse Protection:
Internal fuse (1746-F1 or equivalent) guards against short-circuit fire hazards. For this reason, basic protection is built-in.
Long Hold-Up Time:
Provides 20 ms hold-up at full load and 3000 ms at no load. Thus, the PLC rides through brief power interruptions.
Adjustable Input Voltage:
Jumper pins select 100/120V or 200/240V operation. Therefore, one model fits multiple line voltages.
High Isolation:
1800V AC RMS isolation between input and backplane. Hence, the backplane is protected from line transients.
Leftmost Chassis Mounting:
Installs in the leftmost slot without consuming a slot count. Consequently, all chassis slots remain available for I/O.
Typical Applications
The 1746-P2 suits various SLC 500 power supply applications.
Powering SLC 500 processors and I/O chassis.
Providing 24V DC user power for small field devices.
Upgrading existing SLC 500 systems with higher capacity power supplies.
Replacement of failed power supplies in 1746 chassis.
New SLC 500 system builds requiring 120/220V AC input.
Installation Guidelines
Install the 1746-P2 in the leftmost slot of the SLC 500 chassis. First, ensure the chassis is powered off. Then, slide the power supply into the chassis and secure it.
Set the input voltage jumper pins for either 100/120V AC or 200/240V AC. Connect AC line and neutral wires to the appropriate terminals. Connect the ground terminal to earth ground.
Avoid connecting or disconnecting wires with power applied. Electrical arcs may damage the backplane. For high-inductive loads, consider an isolation transformer to prevent voltage surges.
What is in the Box
Please inspect all items upon delivery.
Allen-Bradley 1746-P2 power supply module.
Installation instruction manual.
Anti-static protective bag.
Frequently Asked Questions (FAQ)
1. What is the input voltage range of the 1746-P2?
The 1746-P2 accepts 85-132V AC or 170-265V AC at 47-63 Hz. Jumper pins select the correct range (100/120V or 200/240V).
2. What are the backplane current ratings of this power supply?
The 1746-P2 provides 5 Amps at 5V DC and 0.46 Amps at 24V DC. The internal current capacity is 5A at 5V and 0.96A at 24V.
3. What is the CPU hold-up time of this power supply?
The hold-up time is 20 ms at full load. At no load, it is 3000 ms. Therefore, the processor continues running during brief power dips.
4. Does the 1746-P2 consume a chassis slot?
No. The 1746-P2 installs in the leftmost slot, but its location is not included in the slot count. Slot Zero (0) is reserved for the processor or communication adapter.
5. What is the difference between Series A/B and Series C overcurrent behavior?
For Series A and B, an overcurrent causes power supply shutdown and a CPU fault. For Series C, only the 24V DC user power shuts down, but the CPU continues operating.