+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

Allen-Bradley 1746-NR8 SLC 500 RTD Input Module 8 Channel Platinum

Introduction:

The 1746-NR8 is an RTD/resistance analog input module for Allen-Bradley SLC 500 systems. It provides 8 channels compatible with Platinum, Copper, and Nickel RTD sensors. This module also accepts direct resistance inputs from 0-150 to 0-1000 Ohms.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen‑Bradley
Series: SLC 500
Part Number: 1746-NR8
Type: RTD/Resistance Analog Input Module
Condition: Subject to stock check
Weight: 0.42
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The 1746-NR8 belongs to the SLC 500 Series. Its product type is an RTD/Resistance Analog Input Module. The product classification is I/O Modules. The current price for this item is ¥4,850 RMB, and the product gross weight is 0.42 kg.

Rockwell Automation designed this module under the Allen-Bradley brand for SLC 500 systems. The 1746-NR8 features eight (8) input channels compatible with various RTD sensors and direct resistance devices. This module works with both Fixed and modular SLC 500 hardware styles. It occupies a single slot in any chassis and requires no external power supply. Therefore, this module suits temperature measurement and position monitoring applications.


Technical Specifications

Supported RTD Sensors

The 1746-NR8 accepts multiple RTD sensor types. Platinum (385) sensors come in 100, 200, 500, and 1000 Ohm versions. Platinum (3916) sensors are also available in 100, 200, 500, and 1000 Ohm. Copper (426) sensors offer 10 Ohm options. Nickel (618) and Nickel (672) sensors provide 120 Ohm each. Nickel Iron (518) sensors deliver 604 Ohm. Consequently, this module supports virtually all common industrial RTD types.

Direct Resistance Input Ranges

The module accepts direct resistance inputs across four ranges. These ranges include 0 to 150 Ohms , 0 to 500 Ohms , 0 to 1000 Ohms , and 0 to 3000 Ohms . This capability allows connection of potentiometers and resistive position sensors. Typical applications include measuring displacement, travel length, and mechanical movement.

Wiring Configurations

The 1746-NR8 supports 2-wire, 3-wire, and 4-wire RTD sensors . For 2-wire RTDs, recommended cable is Belden 9501 shielded cable or equivalent. For 3-wire or 4-wire RTDs, use Belden 9533 or Belden 83503 cable . With 2-wire RTDs, avoid long cable runs as they reduce measurement accuracy. If long runs cannot be avoided, minimize the effect by using a lower gauge cable such as AWG #16 instead of AWG #24 . The Removable Terminal Block (RTB) terminals are intended for single wire connection only.

Update Time and Step Response

The update time ranges from 6 milliseconds to 2 seconds , programmable based on application needs. The step response measures 60 milliseconds in and 2.5 milliseconds out . Therefore, configure the update time to balance speed and noise rejection for your specific process.

Power Consumption

Backplane current consumption is 100 mA at 5 VDC and 55 mA at 24 VDC . Total backplane power consumption reaches 1.82 Watts maximum (0.5W at 5V dc, 1.32W at 24V dc). This moderate power draw allows multiple modules in the same chassis.

A/D Conversion and Filtering

The analog-to-digital conversion method uses sigma-delta modulation . This technique provides high accuracy and noise rejection. The module includes a low-pass digital filter and programmable input filters . Auto-calibration occurs every time the module powers up. Additionally, auto-calibration can be programmed to repeat every 5 minutes.

Isolation and Protection

Continuous isolation measures 5 Volts DC between channels . Between inputs and backplane, isolation reaches 500 Volts AC for 1 minute . Between inputs and chassis ground, isolation also reaches 500 Volts AC for 1 minute . Maximum common mode voltage is ±1 Volt . Maximum permanent overload ratings are ±5 mA for current and ±5 Volts DC .

Resolution and Accuracy

The resolution reaches 0.01 Degrees Celsius . This fine resolution enables precise temperature measurements. For resistance measurements, resolution scales with the selected input range.

Temperature and Environmental Ranges

The operating temperature range spans 0 to 60 degrees Celsius (32 to 140°F) . Storage temperature extends from -40 to 85 degrees Celsius (-40 to 185°F) . Relative humidity tolerance reaches 5 to 95% non-condensing .

Chassis Location

The 1746-NR8 can install in any slot except Slot 0 . Slot 0 is typically reserved for the CPU or special modules. Install this analog input module in any available I/O slot.

Status Indicators

LED indicators monitor channel status and module operation. Use these indicators for quick troubleshooting during system startup and maintenance.

Terminal Block

The compatible terminal block is the Allen-Bradley 1746-RT-35 . This removable terminal block simplifies wiring and module replacement.


Installation Guide

Follow these steps to install your 1746-NR8 correctly.

  1. Power Down the Chassis: Disconnect power from the SLC 500 chassis completely. This prevents electrical damage during installation.

  2. Select a Slot: Choose an available I/O slot. The 1746-NR8 cannot install in Slot 0. Use any other slot.

  3. Insert the Module: Align the 1746-NR8 with the slot guides. Push firmly until the module seats into the backplane connector.

  4. Secure the Module: Tighten the retaining screws at the top and bottom. This secures the analog input module in place.

  5. Wire the Terminal Block: Connect your RTD or resistance sensors to the 1746-RT-35 terminal block. Use appropriate Belden cables for your wiring configuration.

  6. Install the Terminal Block: Plug the wired terminal block into the front of the 1746-NR8 . Ensure it seats fully.

  7. Configure Input Ranges: Set the input type and range for each channel using your programming software. Select RTD type or direct resistance range.

  8. Apply Power: Restore power to the SLC 500 chassis. Verify the module powers up without errors.

  9. Monitor Readings: Check input values from all 8 channels. Confirm that readings match expected temperature or resistance values.


Package List

  • 1 x 1746-NR8 RTD/Resistance Analog Input Module (8 channel)

  • 1 x Removable Terminal Block (1746-RT-35 compatible)

  • 2 x Module retaining screws (pre-installed)

  • 1 x Installation instruction manual

Note: Field wiring, Belden cables, and RTD sensors are sold separately.


Frequently Asked Questions (FAQ)

1. What RTD sensor types work with the 1746-NR8 ?
The module accepts Platinum (385 and 3916) , Copper (426) , Nickel (618 and 672) , and Nickel Iron (518) RTD sensors. Multiple resistance values are available for each type.

2. Can I use 2-wire RTDs with this module?
Yes, the 1746-NR8 supports 2-wire, 3-wire, and 4-wire RTD connections. For 2-wire RTDs, use Belden 9501 shielded cable and keep cable runs short to maintain accuracy.

3. What direct resistance ranges does this module accept?
The module accepts four resistance ranges: 0-150 Ohms, 0-500 Ohms, 0-1000 Ohms, and 0-3000 Ohms . Use these ranges for potentiometers and position sensors.

4. What is the update time for this module?
The update time is programmable from 6 milliseconds to 2 seconds . Faster updates provide quicker response but may increase noise. Slower updates provide better noise rejection.

5. Can I install this module in Slot 0 of the chassis?
No, the 1746-NR8 cannot install in Slot 0 . Install this analog input module in any other available I/O slot. Slot 0 is typically reserved for the CPU or special modules.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links