Allen-Bradley 1746-ITV16 SLC 500 Fast Input Module 16 Channel


Introduction:
16-channel fast response sourcing input module for SLC 500. 0.3ms max ON delay, 0.5ms OFF delay. Nominal 24 VDC operation.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
Module Design and Application
The Allen-Bradley 1746-ITV16 is a fast response discrete input module for the SLC 500 platform. This module provides sixteen input channels in a sourcing wiring configuration. The nominal input voltage is 24 VDC with an operating range of 10 to 30 VDC. Consequently, the 1746-ITV16 suits high-frequency signaling devices such as encoders, totalizers, data loggers, and counters. The module also excels at position monitoring and conveyor control applications.
Fast Response Characteristics
The 1746-ITV16 features exceptionally fast ON and OFF signal transitions. The maximum ON signal delay is only 0.3 ms, while the maximum OFF delay reaches 0.5 ms. Typical delays at 24 VDC operation are even faster at 0.1 ms for ON and 0.25 ms for OFF. Therefore, this module captures high-speed events that standard input modules would miss. The fast response makes it ideal for time-critical applications requiring rapid signal detection.
Input Grouping and Wiring
The 1746-ITV16 arranges all sixteen inputs into a single group. Therefore, no individual channel isolation exists between inputs. The module supports source wiring configuration, meaning the field device supplies current to the input. A removable terminal block simplifies wiring and maintenance. Consequently, you can replace the module without disconnecting field wires.
Technical Specifications
General Specifications
Brand: Allen-Bradley
Manufacturer: Rockwell Automation / Allen-Bradley
Series: SLC 500
Part Number: 1746-ITV16
Module Type: Fast response discrete input module
Wiring Configuration: Source wiring configuration
Number of Inputs: 16
Number of Groups: 1
Input Voltage Specifications
| Parameter | Value |
|---|---|
| Nominal Input Voltage | 24 VDC |
| Input Voltage Range | 10 to 30 VDC |
| Maximum Off-State Voltage | 5 VDC |
| Nominal Input Current | 8 mA at 24 VDC |
| Maximum Off-State Current | 1.0 mA or 1.5 mA (see notes) |
Signal Delay Specifications
| Transition | Maximum Delay | Typical Delay (at 24 VDC) |
|---|---|---|
| ON Signal | 0.3 ms | 0.1 ms |
| OFF Signal | 0.5 ms | 0.25 ms |
Power and Current Specifications
Backplane Current (5 V DC): 85 mA (0.085 A)
Backplane Current (24 V DC): 0 mA
Maximum Power Dissipation: 3.6 W
Filtering and Noise Reduction
Filter Circuitry: Included
Optical Coupling: Included for signal noise reduction
Environmental Specifications
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Operating Humidity | 5 to 95% non-condensing |
Indicators and Diagnostics
LED Indicators: Yes (input status values)
Troubleshooting: Easy with status LEDs
Terminal Block: Removable for wiring convenience
Data Access
Data Storage: Data image table
Processor Access: All modular and fixed SLC 500 processors
Programming Method: Ladder Logic
Installation Guide
Follow these steps to install the Allen-Bradley 1746-ITV16 correctly.
Power Down System: First, disconnect power from the SLC 500 chassis completely.
Select Slot: Next, choose an available slot in the chassis.
Insert Module: Then, slide the 1746-ITV16 firmly into the selected slot.
Secure Module: After that, engage the locking mechanism to hold the module in place.
Wire Inputs: Meanwhile, connect field devices to the removable terminal block.
Apply Power: Finally, restore power and verify the LED indicators.
The 1746-ITV16 requires source wiring configuration for proper operation. Therefore, ensure your field devices supply current to the inputs. In addition, avoid exceeding the maximum off-state voltage of 5 VDC. Consequently, proper installation ensures reliable high-speed input capture.
Package List
The package includes the following physical items.
Allen-Bradley 1746-ITV16 fast response input module (1 piece)
Removable terminal block (installed)
Product label with part number and specifications
Anti-static protective bag for safe transport
Note: Field wiring and external power supply are not included. Mounting screws are not required for chassis installation. No programming software is provided with this module.
Frequently Asked Questions (FAQ)
1. How many inputs does the 1746-ITV16 provide?
The Allen-Bradley 1746-ITV16 provides sixteen fast response discrete inputs. Therefore, the module monitors up to sixteen high-speed field devices. All inputs are arranged in a single group without individual isolation. Consequently, the module suits applications requiring many fast inputs in a compact form factor.
2. What is the input voltage range for the 1746-ITV16?
The Allen-Bradley 1746-ITV16 accepts an input voltage range of 10 to 30 VDC. Therefore, it operates with nominal 24 VDC industrial power supplies. The maximum off-state voltage is 5 VDC, meaning voltages below this threshold read as OFF. Consequently, the module tolerates moderate voltage variations.
3. How fast is the 1746-ITV16 response time?
The Allen-Bradley 1746-ITV16 delivers exceptional speed with maximum ON delay of 0.3 ms and OFF delay of 0.5 ms. Typical delays at 24 VDC are even faster at 0.1 ms ON and 0.25 ms OFF. Therefore, this module captures high-frequency signals that standard input modules would miss. Consequently, it suits encoder, counter, and data logger applications.
4. What is the backplane current draw of the 1746-ITV16?
The Allen-Bradley 1746-ITV16 draws 85 mA (0.085 A) from the 5 V DC backplane. Therefore, the module places a very modest load on the SLC 500 power supply. No current is drawn from the 24 V DC backplane. Consequently, multiple modules can be installed without overloading the power budget.
5. Does the 1746-ITV16 have individual channel isolation?
No, the Allen-Bradley 1746-ITV16 has a single group of sixteen inputs without individual channel isolation. Therefore, all inputs share a common reference. However, optical coupling and filter circuitry provide noise reduction. Consequently, use this module in applications where isolation is not critical.
6. What is the nominal input current of the 1746-ITV16?
The Allen-Bradley 1746-ITV16 has a nominal input current of 8 mA at 24 VDC. Therefore, the module presents a standard load to field devices. The maximum off-state current is 1.0 mA or 1.5 mA depending on specification. Consequently, the module minimizes loading on sensitive signal sources.
7. What types of field devices work with the 1746-ITV16?
The Allen-Bradley 1746-ITV16 works with high-frequency signaling devices requiring fast response. For example, encoders, totalizers, data loggers, and counters are ideal applications. The module also suits position monitoring and conveyor control systems. Consequently, it excels wherever rapid ON/OFF switching occurs.
Related Accessories
Enhance your SLC 500 input system with these compatible parts.
SLC 500 Chassis: Allen-Bradley 1746-A4, A7, A10, or A13 for module mounting
Power Supply: Allen-Bradley 1746-P1, P2, P3, P4, or P5 for backplane power
Processor: Allen-Bradley SLC 500 CPU for ladder logic access
Encoder: High-speed incremental encoder for position feedback
Removable Terminal Block: Allen-Bradley replacement block for field wiring
Always use genuine Allen-Bradley components with the 1746-ITV16. Therefore, third-party terminal blocks may not fit correctly or provide reliable connections. In addition, verify input voltage stays within the 10 to 30 VDC range. Consequently, using authentic parts ensures optimal high-speed input performance and system reliability.