ABB V18345-1004210001 Electro-Pneumatic Positioner HART


Introduction:
The V18345-1004210001 is an electro-pneumatic positioner from ABB. It offers 4-20mA input, HART communication, and ATEX Zone 2 approval.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
ABB V18345-1004210001 Electro-Pneumatic Positioner Overview
The ABB V18345-1004210001 is an electro-pneumatic positioner for control valves. This device features a compact and rugged aluminum case. Protection rating reaches IP65 (NEMA 4X) for harsh environments. The positioner mounts to linear actuators per DIN/IEC 534/NAMUR standards. Alternatively, rotary actuators per VDI/VDE 3845 are also supported. Consequently, the ABB V18345-1004210001 suits a wide range of valve types. A mechanical position indicator provides local position feedback without power.
Ordering Information and Configuration Codes
Manufacturer: ABB.
Part Number: ABB V18345-1004210001.
Product Type: Electro-Pneumatic Positioner.
Case / Mounting (1): Aluminum, varnished case with IP65/NEMA 4X protection. Ready for linear or rotary actuator mounting.
Input / Communication Port (0): Connector plug for LKS adapter and FSK module for HART communication.
Explosion Protection (4): ATEX EEx n A II T6 (Zone 2 approval).
Output / Safe Position (2): Fail freeze mode (position holds on electrical power failure).
Connections (1): Cable entry thread 1/2-14 NPT; air pipe thread 1/4-18 NPT.
Option Modules (0): No analog or digital position feedback module.
Optional Mechanical Kit (0): No mechanical kit for digital position feedback.
Design / Varnish (1): Standard design and coating.
Weight: 1.7 kg.
Input and Communication Specifications
The ABB V18345-1004210001 uses two-wire 4-20 mA technology. Nominal input range is 4 to 20 mA. Split range configuration operates between 20% and 100% of nominal range. Maximum input is 25 mA at 30 V. Minimum starting current is 3.8 mA. Load voltage at 20 mA is 8.7 V DC without explosion protection. For intrinsically safe devices, load voltage reaches 9.7 V DC. Impedance at 20 mA is 435 ohms without protection. For intrinsically safe versions, impedance is 485 ohms. HART Protocol 5.1 is fully supported. Communication occurs via the 20 mA signal line with optional FSK modem. A local connector for LKS adapter enables local configuration.
Digital Input and Output Specifications
Digital Input: Control voltage is 24 V DC (12 to 30 V DC range). Logical 0 receives 0 to 10 V DC. Logical 1 receives 12 to 30 V DC. Maximum current draw is 4 mA.
Digital Output (NAMUR per DIN 19234): Supply voltage is 5 to 11 V DC. Current below 1.0 mA indicates logical 0. Current above 2.0 mA indicates logical 1. Effective direction is configurable as normally logical 0 or logical 1.
Pneumatic Specifications
Output Pressure Range: [Color: Red] 0 to 6 bar (0 to 90 psi) [/Color].
Air Capacity (at 1.4 bar / 20 psi supply): 5.0 kg/h = 3.9 Nm³/h = 2.3 scfm.
Air Capacity (at 6 bar / 90 psi supply): 13 kg/h = 10 Nm³/h = 6.0 scfm. A booster is available on request for higher flow.
Output Function: Supports single or double acting actuators. On electrical power failure, air vents from actuator or actuator blocks (fail freeze mode).
Shut-off Values: End position 0% adjustable from 0 to 45%. End position 100% adjustable from 55 to 100%.
Air Supply Requirements: Instrument air free of oil, water, and dust per DIN/ISO 8573-1. Purity Class 3 with max particle size 5 µm. Oil content max concentration 1 mg/m³. Pressure dew point 10 K below operating temperature.
Supply Pressure Range: 1.4 to 6 bar (20 to 90 psi). Do not exceed actuator maximum operating pressure.
Air Consumption: Less than 0.03 kg/h (0.015 scfm), independent of supply pressure.
Travel and Actuator Specifications
Angle of Rotation (Rotary Actuators): Used range is 25 to 120° (optionally 270°).
Angle of Rotation (Linear Actuators): Used range is 25 to 60°.
Travel Limits: Min and max limits freely configurable within 0 to 100% of total travel. Minimum configurable range is greater than 20%.
Travel Time Prolongation: Adjustable from 0 to 200 seconds, separately for each direction.
Positioning Time Limit: Adjustable from 0 to 200 seconds (monitoring parameter for deviation tolerance band).
Performance Specifications
Characteristic Curve: Linear, equal percentage 1:25, 1:50, 25:1, or 50:1. Freely configurable with 20 reference points.
Characteristic Deviation: ≤ 0.5%.
Tolerance Band: Adjustable from 0.3 to 10%.
Dead Band: Adjustable from 0.1 to 10%.
Resolution (A/D Conversion): Greater than 4000 steps.
Sample Rate: 20 milliseconds.
Influence of Ambient Temperature: ≤ 0.5% for every 10°C temperature change.
Influence of Vibration: ≤ ±1% up to 10 g and 80 Hz.
Seismic Requirements: Meets DIN/IEC 68-3-3 Class III for strong earthquakes.
Influence of Mounting Orientation: No effect on performance.
Environmental and Physical Specifications
Ambient Temperature (Operation, Storage, Transport): -40°C to +85°C.
Ambient Temperature with Proximity Switches: -25°C to +85°C.
Relative Humidity (Operational): 95% annual average, condensation permissible.
Relative Humidity (Transport and Storage): 75% annual average, non-condensing.
Case Material: Aluminum with electrostatic dipping varnish. Color is black RAL 9005 matt with cap Pantone 420.
Protection Class: [Color: Red] IP65 / NEMA 4X [/Color].
Electrical Connections: Screw terminals (max 1.0 mm² for options, max 2.5 mm² for analog signal). Do not expose terminals to strain.
Cable Entries: Two threads 1/2-14 NPT (one with cable gland, one with pipe plug).
Pneumatic Connections: Threads G 1/4 or 1/4-18 NPT.
Hazardous Area Approvals
The ABB V18345-1004210001 carries multiple explosion protection certifications.
ATEX (EEx n A II T6 – Zone 2): Certificate TÜV 02 ATEX 1943 X. Temperature class T4: -40°C < Tamb < 85°C. T5: -40°C < Tamb < 65°C. T6: -40°C < Tamb < 50°C.
ATEX (EEx ib IIC T6 – Intrinsically Safe): Certificate TÜV 98 ATEX 1370 X. Device class II 2G. T4: -40°C < Tamb < 85°C. T5: -40°C < Tamb < 50°C. T6: -40°C < Tamb < 35°C.
FM Approvals: J.I. 3005029 (3610, 3611). Intrinsically safe for Class I, II, III Div 1 Groups A-G. Non-incendive for Div 2 environments.
CSA Certification: 1052414. Intrinsically safe with Enclosure 4X, T4 max 85°C. Suitable for Class I, II, III Div 1 and Div 2.
IECEx: Ex ib IIC T6 per certificate IECEx TUN 04.0015X. Temperature class T4, T5, T6 with same ambient limits as ATEX.
Key Features of V18345-1004210001
The ABB V18345-1004210001 offers low operating cost through efficient air consumption. Well-proven technology ensures reliable operation over many years. The compact design fits tight actuator mounting spaces. A wide operating temperature range from -40°C to +85°C suits extreme environments. Commissioning is easy with the single push-button operating philosophy. A mechanical position indicator works without electrical power. For SIL2 safety loops, this positioner is fully approved. HART communication enables remote configuration and diagnostics. The fail freeze safe position holds actuator position on power loss.
Installation Guidelines for V18345-1004210001
Before starting, disconnect all electrical power and air supply. Mount the ABB V18345-1004210001 to your actuator according to the applicable standard (DIN/IEC 534/NAMUR for linear or VDI/VDE 3845 for rotary). Connect the air supply within 1.4 to 6 bar (20 to 90 psi). Use instrument air meeting DIN/ISO 8573-1 Class 3 requirements. Wire the 4-20 mA input signal to the screw terminals (max 2.5 mm²). For HART communication, ensure the loop impedance is adequate (minimum 250 ohms). Connect the air output pipes to the actuator ports. Configure the fail freeze safe position based on your application needs. Perform auto-calibration using the single push-button. Verify the travel limits and dead band settings before placing in service.
Application Scenarios for V18345-1004210001
The ABB V18345-1004210001 controls linear control valves in process plants. Rotary ball valves and butterfly valves also use this positioner. Refineries benefit from its ATEX Zone 2 approval for safe area operation. Chemical plants rely on its corrosion-resistant aluminum housing. Power generation facilities use it for steam turbine valve control. Oil and gas pipelines need its wide -40°C to +85°C temperature range. For SIL2 safety loops, this positioner meets all requirements. HART communication enables predictive maintenance strategies.
Package List for V18345-1004210001
One ABB V18345-1004210001 electro-pneumatic positioner
One mounting kit for linear or rotary actuator (per order configuration)
One pipe plug for unused cable entry
One product instruction manual
One HART communication quick start guide
Common FAQs about the ABB V18345-1004210001
Q1: What input signal does the V18345-1004210001 accept?
The ABB V18345-1004210001 accepts a 4-20 mA two-wire input. Minimum start current is 3.8 mA. Maximum input is 25 mA at 30 V. Split range configuration is available between 20% and 100% of nominal range.
Q2: What is the fail safe position of this positioner?
Option code 2 provides fail freeze mode. On electrical power failure, the positioner holds the actuator in its last position. Air is neither added nor vented from the actuator.
Q3: What explosion protections does the V18345-1004210001 have?
The ABB V18345-1004210001 has ATEX EEx n A II T6 (Zone 2) approval. It also carries FM, CSA, and IECEx certifications. Intrinsically safe versions are available under the same base model.
Q4: What is the air consumption of this positioner?
Air consumption is less than 0.03 kg/h (0.015 scfm). This value remains independent of supply pressure. Consequently, operating costs are very low compared to competitor devices.
Q5: Does the V18345-1004210001 support HART communication?
Yes, HART Protocol 5.1 is fully supported. Communication occurs via the 20 mA signal line with optional FSK modem. A local LKS adapter connector is also provided for local configuration.