+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

140X816 | Schneider Electric Modbus Plus Adapter 1 Mbps

Introduction:

Schneider Electric 140X816 floating point option adapter for Modicon Momentum. Modbus Plus at 1 Mbps, 450 m transmission, 2.5 W. Field-proven for oil & gas networks.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Schneider Electric
Part Number: 140X816
Condition: Subject to stock check
Shipping Port: Xiamen

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Modbus Plus Networks Demand Reliable Data Transfer — The 140X816 Delivers

In oil & gas operations, communication dropouts on legacy Modbus Plus networks can stall critical processes. The Schneider Electric 140X816 floating point option adapter, part of the Modicon Momentum series, addresses this pain point by ensuring rapid, dependable data flow across connected nodes. Engineered for rugged industrial environments, this adapter supports a communication rate of 1 Mbps, enabling fast exchange of floating-point data between controllers and field devices. Whether you are upgrading an existing Modbus Plus segment or maintaining a mission-critical system, the 140X816 provides a field-proven interface that keeps your network running.

Figure 1: Front view of the Schneider Electric 140X816 industrial automation component showing its physical design and enclosure.

Key Features and Technical Specifications

  • Bus type: Modbus Plus, supporting legacy and current installations.
  • Communication rate: 1 Mbps for rapid data throughput.
  • Connector: 9-pin D-sub female for straightforward integration.
  • Transmission distance: Up to 450 m (1476 ft) without repeaters.
  • Max drops: 32 nodes per segment; addressing for 1 to 64 nodes.
  • Power consumption: 2.5 W, minimizing load on backplane supplies.
  • Cable length: 1.8 m (5.91 ft) included for flexible mounting.
  • Mounting type: B, compatible with standard Modicon Momentum racks.
  • Weight: 0.2 kg (0.44 lbs), reducing mechanical stress on enclosures.
  • Dimensions: 115 mm (L) x 40 mm (H) x 120 mm (D) for compact installation.

The 1 Mbps communication rate is a standout specification, directly reducing scan times and improving response in high-node-count networks typical of oil & gas SCADA systems. The adapter’s low power draw of 2.5 W also helps maintain thermal margins in sealed enclosures.

Applications and Use Cases

The 140X816 is ideally suited for oil & gas applications where Modbus Plus remains a backbone for control and monitoring. In upstream operations, it can bridge floating-point data from flow computers to a central PLC, ensuring accurate custody transfer measurements. Midstream, the adapter supports reliable communication across pipeline compressor stations, where transmission distances up to 450 m are common. Downstream, refineries use it to integrate legacy Modbus Plus devices into modern control systems without costly rewiring. In all these scenarios, the adapter’s rugged design and 1 Mbps throughput help maintain continuous operation, even in demanding environments.

Figure 2: Technical layout and connection details for the Schneider Electric 140X816 industrial automation component.

Installation and Setup

Installing the 140X816 is straightforward thanks to its 9-pin D-sub female connector and mounting type B compatibility. Begin by verifying that the Modbus Plus network is powered down. Mount the adapter securely in the designated slot, ensuring the connector aligns with the backplane. Connect the included 1.8 m cable to the Modbus Plus trunk, observing proper termination and grounding practices to minimize signal reflections. Set the node address (1 to 64) using the rotary switches or software configuration, and confirm the communication rate is set to 1 Mbps. After power-up, verify data exchange using a network diagnostic tool. For detailed wiring diagrams, refer to the official Schneider Electric documentation.

Maintenance and Reliability

To ensure long-term reliability, inspect the adapter and its connections every six months or during scheduled plant turnarounds. Check for loose connectors, cable wear, and environmental factors such as excessive dust or vibration. The 140X816’s solid-state design has no moving parts, minimizing wear points. Its 2.5 W power consumption reduces heat generation, extending component life. In oil & gas environments, where temperature fluctuations and electrical noise are common, maintaining proper grounding and shielding is critical. By following these practices, operators can achieve years of dependable service, reducing downtime and maintenance costs.

Compatibility and Integration

The 140X816 is designed for seamless integration with Modicon Momentum systems and other Modbus Plus devices. It supports up to 32 drops per segment and addresses 1 to 64 nodes, making it versatile for small to medium networks. When integrating into a larger control architecture, ensure that the Modbus Plus network is properly terminated and that all nodes share a common ground reference. For systems requiring connection to Ethernet-based networks, an external gateway may be necessary. Consult PetroPartsOnline for guidance on compatible gateways and cabling to avoid integration issues.

Troubleshooting Common Issues

If communication fails, first verify the 1 Mbps rate setting and node address uniqueness. Check the 9-pin D-sub connector for bent pins or loose cables. Ensure the transmission distance does not exceed 450 m without a repeater. Power issues can be diagnosed by measuring the supply voltage at the adapter; it should be within the specified range. For persistent faults, refer to the official Schneider Electric troubleshooting guide or contact PetroPartsOnline for application-specific support.

Frequently Asked Questions

Q: What is the maximum transmission distance for the 140X816?

A: The adapter supports up to 450 m (1476 ft) on a single Modbus Plus segment without repeaters.

Q: How many nodes can the 140X816 address?

A: It supports addressing for 1 to 64 nodes, with a maximum of 32 drops per segment.

Q: What is the power consumption of this adapter?

A: The 140X816 consumes 2.5 W, making it efficient for backplane power budgets.

Q: Can the 140X816 be used in high-temperature oil & gas environments?

A: While specific operating temperature is not listed, the adapter is designed for industrial use. Refer to the official datasheet for temperature ratings.

Q: What connector type does the 140X816 use?

A: It uses a 9-pin D-sub female connector for Modbus Plus connections.

Product Support and Availability

The Schneider Electric 140X816 is in stock and ready to ship from PetroPartsOnline. Our team provides application-specific selection guidance to ensure you get the right adapter for your Modbus Plus network. Contact PetroPartsOnline for parts suited to your application’s requirements.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap