MTL5018 | Two Channel Hazardous Area Switch/Proximity Detector Module

Introduction:

The MTL5018 enables two safe-area loads to be controlled by two switches or proximity detectors located in a hazardous area. This dual channel unit provides two independent relay outputs with changeover contacts. For each sensor, independent phase reversal control allows an alarm condition to be signalled for either state. A selectable line fault detect (LFD) facility also detects open or short circuits in either field circuit. Therefore, this module suits applications requiring two independent control channels from hazardous area inputs.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: MTL (Measurement Technology Ltd.)
Series: MTL5000 Series
Part Number: MTL5018
Type: Isolated Relay Interface
Condition: Subject to stock check
Weight: 0.22
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview: MTL5018

Designed specifically for dual channel applications, the MTL5018 is a two-channel isolated relay interface. It accepts two independent inputs that conform to NAMUR/DIN 19234 standards for proximity detectors. The unit then drives two safe-area changeover relays, providing one relay for each channel. With independent phase reversal control per channel, maximum configuration flexibility is achieved. Consequently, this interface suits applications requiring two separate control loops from hazardous area switches or proximity detectors.

Technical Specifications

The MTL5018 accepts switches located in Zone 0, IIC, T6 hazardous areas. For proximity detectors, the unit accepts devices located in Zone 0, IIC, T4–6 hazardous areas with suitable certification. Similarly, for North American installations, both switch and proximity detector inputs support Division 1, Group A hazardous locations. Each channel applies 7 to 9V to its sensor from a 1kΩ ±10% source. Therefore, this voltage suits most NAMUR-compliant proximity detectors available today.

  • Number of Channels: Two independent channels

  • Input Type: NAMUR/DIN 19234 compliant per channel

  • Sensor Voltage: 7 to 9V from 1kΩ ±10% per channel

  • Output Type: Two changeover relays (SPDT), one per channel

  • Supply Voltage: 20 to 35V dc

  • LED Indicators: Green (power), two Yellow (output status), two Red (LFD fault)

The MTL5018 maximum current consumption varies with the supply voltage. At 20V, the unit draws 60mA for efficient operation. Under the same conditions at 24V, consumption remains at 60mA. At 35V, however, consumption drops to 40mA for improved energy efficiency. Maximum power dissipation within the unit is 1.4W at 24V and 1.5W at 35V.

Input/Output Characteristics

Standard NAMUR thresholds are followed by the MTL5018 input/output characteristics for reliable switching. In normal phase, the output energises when input current exceeds 2.1mA or resistance drops below 2kΩ. Conversely, the output de-energises when input current falls below 1.2mA or resistance exceeds 10kΩ. In reverse phase, the output operates in the opposite manner for normally closed applications. Hysteresis is 200µA typical, providing stable switching without contact chatter.

  • Switch On Threshold: Iin >2.1mA or Rin <2kΩ

  • Switch Off Threshold: Iin <1.2mA or Rin >10kΩ

  • Hysteresis: 200µA typical

  • Phase Reversal: Independent per channel, user selectable

  • Input Isolation: 250V ac or dc between channels and outputs

Independent phase reversal on the MTL5018 allows each channel to be configured separately. Normal phase means the output energises when the input is active. In contrast, reverse phase means the output de-energises when the input is active. Because of this feature, the unit works with either normally open or normally closed contacts per channel. Thus, mixed configurations are possible on the same unit.

Relay Output Specifications

Two independent single-pole changeover relays (SPDT) are provided by the MTL5018. Each relay has normally open (NO), normally closed (NC), and common (COM) contacts for wiring flexibility. Response time is 10ms maximum from input change to complete relay switching. Contact rating is 250V AC, 2A at power factor greater than 0.7. For DC loads, the rating is 40V DC, 2A for purely resistive loads.

Relay Characteristics for the MTL5018:

  • Response Time: 10ms maximum per channel

  • Contact Rating (AC): 250V, 2A, cosø >0.7

  • Contact Rating (DC): 40V, 2A, resistive load

  • Isolation: 250V ac or dc between power supply, inputs, and relays

  • Contact Type: Single pole, changeover (SPDT) per channel

For inductive loads such as relays, solenoids, or contactors, install suppression devices across the load. Suitable suppression includes RC snubbers for AC loads or flyback diodes for DC loads. Without proper suppression, contact life reduces significantly. As a result, always follow the suppression guidelines provided in the product manual.

Line Fault Detection (LFD)

A selectable line-fault-detection (LFD) facility is included on the MTL5018 for each channel. This feature detects open-circuit or short-circuit faults in each field circuit independently. User-selectable switches located on the top of the unit enable LFD per channel. When enabled, a detected line fault immediately de-energises the corresponding relay. Meanwhile, a red LED illuminates for the affected channel when LFD detects a fault.

LFD Specifications for the MTL5018:

  • Open Circuit Alarm On: Iin < 100µA

  • Open Circuit Alarm Off: Iin > 250µA

  • Short Circuit Alarm On: Rin < 100Ω

  • Short Circuit Alarm Off: Rin > 360Ω

  • User Selectable: Via switches on top of unit

  • LFD Action: De-energises the corresponding channel relay

Reliable fault detection with clear hysteresis is provided by the MTL5018 LFD thresholds. An open circuit turns the alarm on below 100µA and off above 250µA. A short circuit turns the alarm on below 100Ω and off above 360Ω. This hysteresis prevents nuisance alarms due to signal noise. For contact input applications using LFD, however, you must fit external resistors.

Contact Input Resistor Requirements for LFD

For contact input applications using LFD mode, external resistors must be fitted on each channel. Install a 500Ω to 1kΩ resistor in series with each switch. Additionally, install a 20kΩ to 25kΩ resistor in parallel with each switch. These resistors ensure proper line fault detection under all operating conditions. Without these resistors, the LFD feature will not function correctly on that channel.

  • Series Resistor: 500Ω to 1kΩ in series with switch

  • Parallel Resistor: 20kΩ to 25kΩ across switch contacts

  • Application: Each channel requiring LFD with contact input

  • Placement: Install resistors as close to switch as possible

  • Result: Enables open and short circuit detection

When using proximity detectors on the MTL5018, external resistors are not required at all. NAMUR proximity detectors provide the necessary current and resistance characteristics internally. The LFD thresholds work directly with standard NAMUR sensors. Always verify that your proximity detector meets the NAMUR/DIN 19234 standard before installation.

Terminal Connections

Clearly labeled terminals on the MTL5018 simplify field wiring for both channels significantly. Terminals 1 and 2 connect to hazardous-area input channel 1. Meanwhile, terminals 4 and 5 connect to hazardous-area input channel 2. Terminals 3 and 6 provide earth leakage detection connections for each channel. For output relay channel 2, connect terminals 7, 8, and 9 (NC, COM, NO). For output relay channel 1, connect terminals 10, 11, and 12 (NC, COM, NO). Finally, terminals 13 and 14 receive the 20-35V DC supply.

Terminal Functions for the MTL5018:

  • Terminal 1: Input –ve (Channel 1)

  • Terminal 2: Input +ve (Channel 1)

  • Terminal 3: Earth leakage detection (Channel 1)

  • Terminal 4: Input –ve (Channel 2)

  • Terminal 5: Input +ve (Channel 2)

  • Terminal 6: Earth leakage detection (Channel 2)

  • Terminal 7: Normally closed (Channel 2)

  • Terminal 8: Common (Channel 2)

  • Terminal 9: Normally open (Channel 2)

  • Terminal 10: Normally closed (Channel 1)

  • Terminal 11: Common (Channel 1)

  • Terminal 12: Normally open (Channel 1)

  • Terminal 13: Supply –ve

  • Terminal 14: Supply +ve

Always connect the MTL5018 earth leakage terminals (3 and 6) to a reliable earth ground. This connection enables the earth leakage detection feature to function correctly. Use a dedicated earth wire for each channel or share a single earth point. Failure to connect earth may cause nuisance faults or unreliable operation.

LED Indicators

Five LED indicators are featured on the MTL5018 for comprehensive status monitoring. A green LED illuminates when power is applied to the unit correctly. Two yellow LEDs show the status of each channel (on when outputs are energised). Additionally, two red LEDs provide LFD indication for each channel (on when a line fault is detected). Consequently, operators gain immediate visual feedback on system status.

  • Green LED: Power indication (one)

  • Yellow LEDs: Two, one per channel (on when relay energised)

  • Red LEDs: Two, one per channel (on when LFD fault detected)

  • LFD Selection: Via top-mounted switches per channel

  • Fault Indication: Independent per channel for easy diagnostics

Rapid troubleshooting without special tools is assisted by the MTL5018 LED indicators. No power means the green LED remains off completely. In this case, check the supply voltage at terminals 13 and 14. If a yellow LED does not match expected input status, check the corresponding input wiring. If a red LED illuminates, check for open or short circuits in that channel’s field wiring immediately.

Isolation and Safety

The MTL5018 provides 250V ac or dc isolation between power supply, hazardous-area circuits, and relay outputs. This galvanic isolation prevents fault currents from passing between circuits. Each channel is also isolated from the other for truly independent operation. The safety description provides entity parameters for hazardous area calculations per channel. Um is 250V rms or DC for the associated apparatus.

  • Isolation: 250V ac or dc between circuits

  • Isolation Type: Galvanic between supply, inputs, and outputs

  • Channel Isolation: Independent between channel 1 and channel 2

  • Voc (Vmax) per channel: 10.5V

  • Isc (Imax) per channel: 14mA

  • Ca (La) per channel: 800Ω

When using the MTL5018 in hazardous areas, observe the temperature classification limits carefully. For switch inputs, the unit supports T6 classification for high-temperature applications. For proximity detector inputs, the unit supports T4 to T6 depending on the detector certification. Always verify that each field device meets the required temperature class for your specific application.

Installation Guidelines

Install the MTL5018 on a standard DIN rail inside a safe-area enclosure. Mount the unit vertically for optimal convection cooling and heat dissipation. First, configure the LFD and phase reversal switches located on top of the unit. Next, connect the hazardous-area input wires to terminals 1-2 (channel 1) and 4-5 (channel 2). Then connect the safe-area loads to the appropriate relay terminals (7-12). After that, connect earth ground to terminals 3 and 6 for safety. Finally, apply 20-35V DC power to terminals 13 and 14 for operation.

Key Installation Points for the MTL5018:

  • Mounting: Use standard 35mm top hat DIN rail

  • Orientation: Mount vertically for optimal cooling

  • Switch Settings: Configure LFD and phase before wiring

  • Wire Gauge: Use 0.2 to 2.5 mm² (24 to 14 AWG)

  • Earth Connection: Always connect terminals 3 and 6 to ground

  • LFD Resistors: Install series and parallel resistors for contact inputs per channel

For contact input applications using LFD mode, install the external resistors on each required channel. Place the 500Ω to 1kΩ resistor in series with one switch wire per channel. Place the 20kΩ to 25kΩ resistor directly across the switch contacts per channel. Solder or terminate these resistors as close to each switch as possible. Without these resistors, the LFD feature will not detect open or short circuits correctly on that channel.

Package Contents

Your purchase of the MTL5018 includes:

  • (1) MTL Dual Channel Isolated Relay Interface – MTL5018

  • (1) DIN rail mounting clip (factory installed)

  • (1) Product documentation leaflet

  • (1) Standard anti-static packaging

Frequently Asked Questions (FAQ)

Q: How many independent channels does the MTL5018 provide?
A: Two completely independent channels are provided by the MTL5018. Each channel has its own NAMUR input, relay output, phase reversal control, and LFD detection.

Q: What input types does the MTL5018 accept per channel?
A: The MTL5018 accepts NAMUR/DIN 19234 proximity detectors or simple mechanical switches per channel. For switches using LFD mode, however, you must install external series and parallel resistors.

Q: Can I configure phase reversal independently per channel on the MTL5018?
A: Yes, independent phase reversal control for each channel is allowed by the MTL5018. This means one channel can operate in normal phase while the other operates in reverse phase simultaneously.

Q: Does the MTL5018 detect line faults on both channels?
A: Yes, independent line-fault-detection (LFD) for each channel is featured on the MTL5018. Two red LEDs indicate fault status separately for channel 1 and channel 2.

Q: What hazardous area zones does the MTL5018 support?
A: The MTL5018 supports Zone 0, IIC, T6 for switch inputs and Zone 0, IIC, T4-6 for proximity detectors. For North America, the unit supports Division 1, Group A hazardous locations.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap