Schneider Electric 140NOA62200 Interbus Master Module Quantum

Introduction:

Schneider Electric 140NOA62200 Interbus master module for Modicon Quantum. Generation 4, PCP V2.0. 500 kbit/s, twisted pair cable.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Schneider Electric
Series: Modicon Quantum
Part Number: 140NOA62200
Type: Interbus Master Module
Condition: Subject to stock check
Weight: 0.9
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Schneider Electric 140NOA62200 Interbus Master Module

The Schneider Electric 140NOA62200 is an Interbus master module for the Modicon Quantum platform. Specifically, this is a Generation 4 module with PCP V2.0 profile. Therefore, you can connect Interbus remote I/O networks directly to your Quantum PLC. Designed for standard applications, this module consequently serves as a master on the Interbus network. Moreover, it works with both Concept and ProWORX 32 software (V 2.5 SR2 or later). Thus, programming flexibility is ensured across different development environments.

Technical Specifications of the 140NOA62200

Regarding communication, the Schneider Electric 140NOA62200 uses Interbus RS485 isolated protocol. The transmission speed is 500 kbit/s per DIN 66020 standard. Twisted pair cable is required for the serial link. Furthermore, the maximum cable distance between devices is 20 meters (65.6 feet). The module also occupies a standard format in the Quantum rack for easy integration.

Hardware Compatibility

Several CPUs are compatible with this Interbus master module. For local rack Interbus networks, the Schneider Electric 140NOA62200 works with 6 x 140CPU11303 modules. Similarly, with 140CPU43412A or 140CPU53414B CPUs, up to 2 modules are supported. However, the module is designed for local rack installation only. Therefore, it cannot be used in remote or distributed racks.

Memory and Processing

Ample memory is provided on this Interbus master module. Firmware EPROM includes 128 kB + 256 kB of storage. Additionally, dual-port RAM offers 2 kB for fast data exchange. For data storage, 256 kB + 32 kB of RAM is available. Interbus command sequence EEPROM also provides 64 kB. Furthermore, multi-port RAM includes an additional 64 kB of capacity. Consequently, the module can handle complex Interbus networks efficiently.

Power and Current

Bus current requirement for the Schneider Electric 140NOA62200 is 800 mA. Moreover, power dissipation is only 4 Watts for efficient operation. Thus, these ratings ensure reliable performance within the Quantum backplane limits.

Local Signaling (LED Indicators)

Extensive LED diagnostics are provided on this module. First, a green ACTIVE LED shows communication with the Quantum CPU. Second, a green RUN LED indicates firmware and module operation. Third, another green IS-B RUN LED shows normal Interbus function with data carrying. Therefore, you have three positive status indicators at a glance.

For fault conditions, several red LEDs are available. A red F LED indicates a module fault. Likewise, a red LED shows initialization fault with the DEA 202. Another red LED indicates the Interbus master is not operational. A separate red LED also shows that the Interbus module has reported a fault. Memory faults trigger a dedicated red LED as well. Peripheral bus faults and processor faults (master) each have their own red LEDs. Additionally, a remote bus fault has its own dedicated red indicator. Finally, a yellow LED indicates that one or more bus segments are shut down. Thus, troubleshooting is straightforward and efficient.

Electrical Connections

The Schneider Electric 140NOA62200 uses two SUB-D 9 connectors. One connector serves general electrical connection. Meanwhile, the other SUB-D 9 connector is specifically for the Interbus link. Consequently, network connection is separate from programming access. CE marking is also present for European compliance.

Certifications and Environment

Product certifications include CSA and UL for North American markets. For electrostatic discharge, the module handles 4 kV contact per IEC 801-2. Likewise, it withstands 8 kV on air per the same standard. Regarding electromagnetic fields, it resists 10 V/m from 80 to 1000 MHz per IEC 801-3. Operating temperature ranges from 0°C to 60°C. In addition, storage temperature expands from -40°C to 85°C. Relative humidity can reach 95% without condensation. Finally, operating altitude is up to 5000 meters for flexible installation.

Physical Specifications

The Schneider Electric 140NOA62200 uses a standard module format. Product weight is 2.0 lb (0.9 kg). Furthermore, the country of origin is DE (Germany). Therefore, European manufacturing quality is assured.

Installation Guidelines for the 140NOA62200

First, mount the Schneider Electric 140NOA62200 in a Quantum local rack. For 140CPU11303 systems, up to 6 modules are allowed in the same rack. However, for 140CPU43412A or 140CPU53414B systems, limit installation to only 2 modules. Then, connect the Interbus network using twisted pair cable to the SUB-D 9 connector. Be sure to observe the 20-meter maximum distance between devices. After that, configure the module using Concept or ProWORX 32 software (V 2.5 SR2 or later). Finally, verify that all LED indicators show normal operation before placing the system online.

Package Contents

  • One (1) Schneider Electric 140NOA62200 Interbus master module

  • Installation and configuration manual

Common FAQs for the 140NOA62200

1. Which software versions work with the 140NOA62200?
The Schneider Electric 140NOA62200 works with Concept and ProWORX 32. However, software version V 2.5 SR2 or later is required.

2. How many modules can be installed in one Quantum rack?
For 140CPU11303, up to 6 of the Schneider Electric 140NOA62200 modules are allowed. In contrast, for 140CPU43412A or 140CPU53414B, only 2 modules are supported.

3. What is the communication speed of this module?
The Schneider Electric 140NOA62200 communicates at 500 kbit/s. Moreover, the protocol is Interbus RS485 isolated per DIN 66020.

4. What type of cable is required for the Interbus link?
Twisted pair cable is required for the Schneider Electric 140NOA62200. Furthermore, the maximum distance between devices is 20 meters (65.6 feet).

5. How many LEDs are on this module for diagnostics?
The Schneider Electric 140NOA62200 has extensive LED diagnostics. Specifically, it includes 3 green LEDs, 1 yellow LED, and multiple red LEDs for various fault conditions. Therefore, troubleshooting is very efficient.

Why Choose the Schneider Electric 140NOA62200?

This Generation 4 Interbus master module provides reliable remote I/O connectivity for Modicon Quantum systems. The 500 kbit/s speed suits medium-speed automation networks. Furthermore, extensive LED diagnostics simplify troubleshooting significantly. Support for both Concept and ProWORX 32 also offers excellent programming flexibility. Order the Schneider Electric 140NOA62200 today for your Interbus master needs.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap