IC698RMX016 | GE RX7i Redundant Memory Module 16MB




Introduction:
The GE IC698RMX016 is a Redundant Memory Exchange Module for the RX7i PACSystem, providing 16MB SDRAM and fiber-optic links for mission-critical redundant CPU configurations.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Redundant Memory Exchange for Mission-Critical RX7i Systems
In oil & gas operations, control system downtime can cost thousands per hour. The IC698RMX016 from GE (formerly GE Intelligent Platforms, now under Emerson Automation) is a Redundant Memory Exchange Module designed for the PACSystem RX7i platform. It serves as a node on a reflective memory network or as a memory link between partner CPU modules in a redundant pair, ensuring continuous operation even if one CPU fails. Built for demanding environments, this module delivers the reliability you can depend on when process uptime is non-negotiable.

Key Features & Technical Specifications
- User Memory: 16 MB SDRAM for reflective memory or redundant data exchange.
- Operating Voltage: +5 VDC supplied from the RX7i backplane power supply.
- Current Requirement: 1.8 A, ensuring compatibility with standard RX7i power budgets.
- Operating Temperature: -20°C to +85°C, suitable for harsh industrial environments.
- Fiber Optic Connectors: LC type per IEC 61754-20 with zirconium ceramic ferrule.
- Insertion Loss: 0.35 dB maximum, minimizing signal degradation over fiber links.
- Return Loss: -30 dB, ensuring reliable optical performance.
- Packet Size: Dynamic, automatically controlled by the Memory Xchange module (4–64 bytes).
- Network Capacity: Up to 256 nodes per network for large-scale reflective memory systems.
- Dimensions: 6.299” (W) x 9.187” (H), single-slot module.
Each specification translates directly to cost and efficiency: the 16 MB memory reduces the need for external data buffering, the wide temperature range eliminates costly cooling or heating in remote cabinets, and the low insertion loss extends fiber link distances without repeaters.
Cost-Efficiency Through Reliable Redundancy
The IC698RMX016 is engineered to minimize total cost of ownership in oil & gas applications. By enabling redundant CPU configurations, it prevents unplanned shutdowns that can cost tens of thousands of dollars per hour. The module’s fiber-optic interface with 0.35 dB maximum insertion loss allows longer cable runs between cabinets, reducing the need for additional hardware and installation complexity. The 1.8 A current draw at +5 VDC is modest, keeping power supply sizing and energy costs predictable. And with an operating temperature range of -20°C to +85°C, the module operates reliably in field enclosures without expensive climate control, even in desert or arctic installations.

Applications & Use Cases
This module is ideal for redundant control systems in critical oil & gas processes. In a pipeline compressor station, two RX7i CPUs can be configured as a redundant pair with the IC698RMX016 exchanging memory between them, ensuring that if the primary CPU fails, the secondary takes over without process interruption. For distributed control across a refinery, the module can serve as a node on a reflective memory network, sharing data among up to 256 nodes with deterministic performance. The wide temperature range also makes it suitable for remote wellhead control cabinets where temperatures fluctuate widely. In each case, the module’s fiber-optic links provide noise immunity and isolation, essential in electrically noisy industrial environments.
Installation & Setup
The IC698RMX016 mounts in the main rack of an RX7i backplane. For optimal interrupt priority, install it in Rack 3 or 4, though other slots are supported. The module requires RX7i CPU firmware version 2.00 or later. During power-up, the module remains unconfigured until the host CPU sends the hardware configuration. For general-purpose reflective memory operation, parameters such as Node ID, Redundant Transfer Mode, Rogue Master, Network Memory Offset, and Interrupt Enable can be configured using Logic Developer PC software. In redundant CPU operation, these parameters are automatically set by the CPU and cannot be manually configured. The front panel includes 8 LED indicators and a toggle switch for role authorization, preventing accidental role changes. The fiber optic connectors are LC type; ensure proper cleaning and mating to maintain insertion loss below 0.35 dB.
Maintenance & Reliability
To maintain reliable operation, inspect fiber optic connectors periodically for contamination, which can increase insertion loss and degrade signal quality. The module’s wide operating temperature range reduces thermal stress on components, extending service life. In redundant configurations, regularly test the role-switch function to ensure failover capability. Because the module uses fiber optics, it is immune to EMI, reducing maintenance compared to copper-based links. The 16 MB SDRAM has no moving parts, contributing to long-term reliability. Following these practices helps avoid unplanned downtime and preserves the cost benefits of redundancy.
Compatibility & Integration
The IC698RMX016 is part of the PACSystem RX7i platform and requires an RX7i CPU and backplane. It communicates over a high-speed fiber optic network using LC connectors. For integration into existing systems, ensure that all nodes on the reflective memory network are compatible with the Memory Xchange protocol. When connecting to other equipment, verify fiber type and connector compatibility. Integration Note: Wiring into fieldbus networks such as PROFINET or EtherNet/IP may require an external gateway or connection module; confirm cables and gateways with the supplier.
Frequently Asked Questions
Q: What is the power supply requirement for the IC698RMX016?
A: The module operates on +5 VDC supplied from the RX7i backplane and draws 1.8 A. Ensure your power supply can accommodate this load.
Q: Can the IC698RMX016 be used in non-redundant applications?
A: Yes, it can function as a node on a reflective memory network for general-purpose data sharing among up to 256 nodes.
Q: What is the maximum insertion loss of the fiber optic connectors?
A: The module’s LC connectors have a maximum insertion loss of 0.35 dB, ensuring reliable optical signal transmission.
Q: What firmware version is required for the RX7i CPU?
A: The IC698RMX016 requires RX7i CPU firmware version 2.00 or later. Refer to official GE documentation for detailed compatibility.
Q: How does the module handle configuration in redundant mode?
A: In redundant operation, parameters like Node ID and Redundant Transfer Mode are automatically set by the CPU and cannot be manually configured.
Product Support & Availability
PetroPartsOnline stocks the IC698RMX016 and offers application-specific selection guidance to ensure compatibility with your RX7i system. Contact PetroPartsOnline for parts suited to your application’s requirements.