DL50-N2225 | SICK 50 m HDDM Laser Distance Sensor



Introduction:
The SICK DL50-N2225 is a field-proven laser distance sensor with HDDM technology, 50 m range, and ±3 mm accuracy for rugged oil and gas automation.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
DL50-N2225: Rugged Laser Distance Sensing for Critical Operations
The SICK DL50-N2225 is a high-precision optical time-of-flight distance sensor from the Dx50 series. It delivers reliable measurement over a range of 200 mm to 50,000 mm on Diamond Grade reflective tape, with an accuracy of ± 3 mm. Built for demanding environments, this sensor combines HDDM™ technology with a zinc die-cast housing to withstand the rigors of oil and gas automation.

Why This unit Excels in Harsh Conditions
Maintenance engineers in oil and gas face constant challenges: extreme temperatures, dust, vibration, and the need for dependable measurements. This unit addresses these with a rugged design and advanced optics. Its HDDM™ measurement principle ensures stable readings even under varying ambient light, while the IP65 enclosure protects against dust and water jets. The sensor operates from -30 °C to +65 °C as standard, and with optional cooling plates, it can handle up to +80 °C or even +140 °C with a protection filter. This flexibility makes it suitable for both upstream and downstream applications.
Key Technical Specifications
- Measurement Range: 200 mm … 50,000 mm on Diamond Grade reflective tape
- Measurement Accuracy: ± 3 mm
- Repeatability: ≥ 1 mm
- Light Source: Visible red laser diode, 658 nm, Class 1 eye-safe (IEC 60825-1:2014)
- Response Time: Fast: 15 ms / Medium: 30 ms / Slow: 80 ms (averaging setting)
- Supply Voltage: DC 10 V … 30 V, reverse-polarity protected
- Power Consumption: ≤ 2.1 W (without external load)
- Output & Communication: 1x NPN digital output (≤ 100 mA), RS-422 serial interface, multifunctional input
- Electrical Connection: Male connector M12, 5-pin
- Enclosure Rating: IP65 (EN 60529)
- Operating Temperature: -30 °C … +65 °C (standard); up to +80 °C with 2 cooling plates; up to +140 °C with 2 cooling plates and protection filter
- Storage Temperature: -40 °C … +75 °C
- Housing Material: Zinc die-cast (ZNAL4CU1) with acrylic glass (PMMA) optical window
- Dimensions (W x H x D): 36.1 mm x 62.7 mm x 57.7 mm
- Weight: Approx. 200 g

Installation and Commissioning Best Practices
Proper installation is key to reliable performance. Mount This unit securely using the designated mounting holes; the zinc die-cast housing provides rigidity but should not be subjected to excessive torque. Ensure the laser beam is aligned with the target; the visible red spot aids in setup. The M12 5-pin connector provides a robust electrical interface—tighten the connector to prevent moisture ingress. For serial communication via RS-422, use shielded twisted-pair cable and keep cable runs away from high-voltage lines. The multifunctional input can be configured for various triggers; refer to the official SICK documentation for configuration details.
Maintenance and Troubleshooting for Long Service Life
Regular inspection extends sensor life. Clean the PMMA optical window with a soft, lint-free cloth and mild detergent; avoid abrasive materials. Check the connector for corrosion or loose connections, especially in humid or corrosive atmospheres. The sensor has no user-serviceable internal parts; if measurement drift occurs, verify the target reflectivity and alignment. Common issues include reduced range due to contaminated optics or misalignment; both can be resolved by cleaning and realigning. For persistent faults, consult SICK technical support or PetroPartsOnline for application-specific guidance.
Frequently Asked Questions
What is the maximum measurement range of This unit?
The SICK unit measures up to 50,000 mm on Diamond Grade reflective tape, with a minimum range of 200 mm.
Can This unit operate in high-temperature environments?
Yes, the standard operating temperature is -30 °C to +65 °C. With two cooling plates, it extends to +80 °C, and with an additional protection filter, up to +140 °C (Uv ≤ 24 V).
What type of output does This unit provide?
It offers one NPN digital output (≤ 100 mA) and an RS-422 serial interface, plus a multifunctional input for flexible integration.
Is This unit eye-safe?
Yes, it is Class 1 laser product according to IEC 60825-1:2014 and EN 60825-1:2014, making it safe for operation without additional precautions.
How does This unit handle ambient light interference?
The HDDM™ optical time-of-flight principle provides high ambient light stability, ensuring reliable measurements even in bright conditions.
For parts suited to your application’s requirements, contact PetroPartsOnline.
