Allen-Bradley 1756-OB8EI ControlLogix Fused Output Module


Introduction:
The 1756-OB8EI is an 8-point isolated output module with electronic fusing. It provides 2A per channel at 60°C for demanding ControlLogix applications.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Allen-Bradley 1756-OB8EI is a discrete output module from the ControlLogix product family. This module features eight (8) electronically fused and individually isolated output channels. It delivers a nominal 24VDC output with a voltage range of 10-30VDC.
The module is generally used to energize electrical loads such as relay coils, pilot lamps, buzzers, horns, sirens, valves, and other actuating devices. Therefore, it suits demanding industrial control applications requiring high current per channel.
General Specifications
The 1756-OB8EI offers robust output capabilities for ControlLogix systems.
Manufacturer: Rockwell Automation.
Brand: Allen-Bradley.
Series: ControlLogix.
Part Number/Catalog No.: 1756-OB8EI.
Module Type: Digital DC Sourcing Output.
Number of Outputs: Eight (8) electronically-fused, individually isolated channels.
Output Voltage: 24VDC nominal.
Output Voltage Range: 10-30 VDC.
Enclosure Type Rating: None (open-style).
Output Current Ratings
The 1756-OB8EI delivers substantial current per channel with derating.
Output Current per Channel (nominal at 60°C): 2 Amps.
Output Current per Module (max at 60°C): 10 Amps.
Output Current per Module (max at 55°C): 16 Amps (linear derating).
Surge Current Rating per Point: 4 Amps for 10 ms, repeatable every 2 seconds.
Minimum Load Current: 3 mA.
Maximum Off-State Leakage Current: 1 mA per point.
Maximum Voltage Drop: 1.2 VDC at 2 Amps.
Electronic Fusing and Short Circuit Protection
The 1756-OB8EI includes electronic fusing for enhanced protection.
Short Circuit Trip Threshold: Greater than 4.5 Amps.
Trip Time (output on, then short): Maximum 500 µs.
Trip Time (output on into short): Maximum 1.5 ms.
Diagnostics Timestamp: ±1 ms.
Thus, the module protects itself and connected loads from overcurrent conditions.
Output Signal Delays
The 1756-OB8EI has defined switching characteristics.
OFF to ON Delay (Maximum): 1 ms.
ON to OFF Delay (Maximum): 5 ms.
Backplane Power Consumption
The 1756-OB8EI draws power from the ControlLogix backplane.
Backplane Current (5.1 VDC): 250 milliamps.
Backplane Current (24 VDC): 2 milliamps.
Total Backplane Power: 1.30 Watts.
Power Dissipation (Max at 60°C): 4.7 Watts.
Maximum Thermal Dissipation: 16.03 BTU/hr.
Isolation Voltage: 50 Volts continuous (250V continuous per detailed specs).
Dielectric Test: Routine-tested for 2 seconds at 1350V.
Removable Terminal Blocks (RTB)
The 1756-OB8EI requires a removable terminal block for field wiring.
Compatible RTBs: 1756-TBCH or 1756-TBS6H.
RTBs provide modular connection to output devices. During module replacement, the entire RTB is removed and transferred to the replacement module. Consequently, wiring rework is prevented.
Configurable Fault and Program Modes
The 1756-OB8EI allows per-point configuration for fault and program states.
Configurable Options: Hold Last State, On, or Off.
Fault Mode Default: Off.
Program Mode Default: Off.
LED Indicators
The 1756-OB8EI provides visual status indication.
LED Function: Shows module status and individual I/O status.
Diagnostics Timestamp: ±1 ms for fault detection.
Hence, operators can quickly identify channel status and fault conditions.
Environmental Specifications
The 1756-OB8EI withstands typical industrial conditions.
Operating Temperature: 0 to 60°C.
Non-Operating (Storage) Temperature: -40 to 85°C.
Maximum Surrounding Air Temperature: 60°C.
Relative Humidity: 5-95% (non-condensing).
Installation Guidelines
Install the 1756-OB8EI in any available slot of a 1756 ControlLogix chassis. The module occupies a single slot and permits multiple instances on local or distributed I/O racks.
First, install and ground the chassis and power supply prior to installing the module. Then, insert the module into an available slot. Select a compatible RTB: 1756-TBCH or 1756-TBS6H. Install the RTB onto the module.
Connect field devices to the RTB terminals. The module provides 8 individually isolated sourcing outputs. Each output can deliver 2 Amps at 60°C (10 Amps total per module). At 55°C, the total per module increases to 16 Amps with linear derating.
Configure fault and program mode states per point as required. The default setting for both is Off.
What is in the Box
Please inspect all items upon delivery.
Allen-Bradley 1756-OB8EI output module.
Installation instruction manual.
Anti-static protective bag.
Note: Removable Terminal Block (1756-TBCH or 1756-TBS6H) is sold separately.
Frequently Asked Questions (FAQ)
1. How many output channels does the 1756-OB8EI have?
The 1756-OB8EI provides eight (8) individually isolated output channels. Each channel is electronically fused for protection.
2. What is the maximum current per channel at 60°C?
At 60°C, each channel on the 1756-OB8EI can deliver up to 2 Amps. The total per module at 60°C is 10 Amps.
3. What is the difference between this module and standard output modules?
The 1756-OB8EI features electronic fusing and individual channel isolation. Standard output modules typically have groups of common outputs without per-channel fusing.
4. What RTBs are compatible with this module?
The 1756-OB8EI requires either the 1756-TBCH or 1756-TBS6H removable terminal block. Therefore, order the RTB separately if not already available.
5. What are the configurable fault mode options on this module?
For each channel, the 1756-OB8EI allows configuration of Fault Mode and Program Mode states. The options are Hold Last State, On, or Off. The default setting for both is Off.