+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

ADV561-P50 Yokogawa | Isolated Digital Output with Pulse Function

Introduction:

Yokogawa ADV561-P50 Digital Output Module. 64-channel, 24V DC, isolated outputs. Pulse width and time-proportional output functions.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Yokogawa
Series: ADV561 Series
Part Number: ADV561-P50
Type: Digital Output Module
Condition: Subject to stock check
Weight: 0.45
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The Yokogawa ADV561-P50 is a digital output module for distributed control systems. It provides 64 isolated output channels at 24V DC. This module features pulse width and time-proportional output functions. The Yokogawa ADV561-P50 uses a current sink output format for reliable switching. Users trust this module for high-density digital control applications.


Technical Specifications

The ADV561-P50 delivers robust digital output with advanced timing functions. Below are the complete technical details.

General Specifications

  • Manufacturer: Yokogawa for industrial automation reliability.

  • Product Type: Digital Output Module.

  • Product Number: ADV561-P50 for precise identification.

  • Model: ADV561 Digital Output Module (64-channel, 24V DC, Isolated).

  • Suffix Code P: With pulse width output function and time-proportional output function.

  • Suffix Code 5: Without status display; with no explosion protection.

  • Suffix Code 0: Basic type configuration.

  • Weight: Approx. 0.30 kg for lightweight installation.

Output Channel Specifications

  • Number of Output Channels: 64 isolated output channels.

  • Rated Applied Voltage: 24V DC nominal.

  • Output Format: Current sink for standard industrial loads.

  • Maximum Load Current: 100 mA per channel at 26.4V.

  • Output ON Voltage Maximum: 2V DC across the output.

  • Leak Current Maximum (Output OFF): 0.1 mA for minimal leakage.

External Power Supply

  • External Power Supply Rating: 24V DC, 100 mA required.

  • External Power Supply Voltage Range: 20.4 to 26.4V DC.

  • Power Tolerance: Wide range for industrial flexibility.

Withstanding Voltage and Isolation

  • Between Output Signal and System: 2 kV AC for 1 minute.

  • Between Commons: 500 V AC for 1 minute.

  • Common Configuration: Common minus (-) side every 16 channels.

  • Isolation Quality: Robust protection for noisy environments.

Output Functions

  • Status Output Function: ON/OFF status output available.

  • Pulse Width Output: One-shot pulse width output function.

  • Time-Proportional Output: Time-proportional ON/OFF output function.

  • Function Flexibility: Multiple output modes for various applications.

Output Response Time

  • Status Output Only: 3 ms or less.

  • Mixed Status and Pulse Outputs: 10 ms or less.

  • Response Speed: Fast enough for most control loops.

Pulse Specifications

  • Pulse Width Range: 8 ms to 7200 seconds.

  • Pulse Width Resolution: 8 ms increments.

  • ON/OFF Delay: Maximum 1 ms added to set pulse width.

  • Timing Accuracy: Precise control for time-based applications.

Power Consumption

  • Maximum Current (5V DC): 700 mA from system backplane.

  • Maximum Current (External Power Supply): 120 mA at 24V DC.

  • Total Power: Moderate consumption for 64 channels.

External Connection Options

  • Dedicated Cable: AKB337 for Yokogawa system integration.

  • MIL Connector Cable: For high-density field wiring.

  • Connection Flexibility: Choose based on installation needs.


Installation Guide

Follow these steps to install the Yokogawa ADV561-P50 correctly.

  1. Power Down the System: Turn off all power to the I/O rack.

  2. Locate the Slot: Find an available slot in the Yokogawa base plate.

  3. Insert the Module: Slide the ADV561-P50 into the slot until seated.

  4. Secure the Module: Lock the module using the retaining mechanism.

  5. Connect External Power: Supply 24V DC (20.4 to 26.4V) to the external power terminals.

  6. Install Cables: Connect AKB337 dedicated cable or MIL connector cable.

  7. Wire Field Devices: Connect loads to the output channels (current sink configuration).

  8. Verify Load Current: Ensure each channel does not exceed 100 mA.

  9. Check Common Wiring: Verify common minus (-) side wiring for each 16-channel group.

  10. Apply Power: Turn on the system and external power supply.

  11. Configure Output Functions: Set pulse width or time-proportional parameters as needed.

  12. Test Status Output: Verify ON/OFF switching within 3 ms response time.

  13. Test Pulse Output: Verify pulse width accuracy at the desired setting.

  14. Monitor Leakage Current: Check OFF-state leakage stays below 0.1 mA.

Installation Notes

  • The module provides 64 isolated channels with current sink output.

  • Withstanding voltage is 2 kV AC between output and system.

  • The output ON voltage maximum is 2V DC.

  • Pulse width ranges from 8 ms to 7200 seconds.

  • Common configuration uses minus (-) side every 16 channels.


Packaging List

This unit ships as a new and original product.

  • Yokogawa ADV561-P50 Digital Output Module

  • Product data sheet with channel assignments

  • External power supply connection guide

  • Anti-static factory packaging box


Frequently Asked Questions (FAQ)

1. What output functions does the ADV561-P50 support?
The Yokogawa ADV561-P50 supports status output, pulse width output, and time-proportional output. The -P suffix code enables these advanced timing functions.

2. How many output channels does this module provide?
The ADV561-P50 provides 64 isolated digital output channels. Each channel operates at 24V DC with a maximum load current of 100 mA.

3. What is the response time for status output on this module?
For status output only, the Yokogawa ADV561-P50 responds in 3 ms or less. For mixed status and pulse outputs, response time is 10 ms or less.

4. What is the isolation rating for the ADV561-P50?
The ADV561-P50 provides 2 kV AC for 1 minute between output signal and system. Between commons, isolation is 500 V AC for 1 minute.

5. What external power supply does this module require?
The Yokogawa ADV561-P50 requires an external power supply rated at 24V DC, 100 mA. The acceptable voltage range is 20.4 to 26.4V DC.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap