+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

Beckhoff EL1862 | EtherCAT Terminal 16-Channel Digital Input

Introduction:

Beckhoff EL1862 EtherCAT terminal. 16-channel digital input, 24V DC, 3ms filter, flat-ribbon cable connection, type 1/3 input.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Beckoff
Series: EtherCAT Terminal Series
Part Number: EL1862
Type: Digital Input Terminal
Condition: In Stock
Origin: U.S.A
Weight: 0.6
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Beckhoff EL1862 – EtherCAT Terminal, 16-Channel Digital Input, 24V DC, 3ms

The Beckhoff EL1862 is an EtherCAT digital input terminal. Specifically, this terminal offers 16 channels in a very compact design. It features a 20-pin contact strip for secure connector attachment. Furthermore, it uses insulation displacement contact technology as found in ribbon cables. Consequently, this significantly simplifies the wiring of many channels.

Ordering Configuration and Product Identification

  • Product Status: Regular delivery.

  • Connection Technology: Flat-ribbon cable.

  • Number of Inputs: 16 channels total.

  • Nominal Voltage: 24 V DC (-15%/+20%).

  • Rated Current (per connection pin): 1 A maximum.

  • Input Filter: Typical 3.0 milliseconds.

  • Weight: Approximately 60 grams.

  • Special Features: Also available as ground switching.

  • Configuration: No address or configuration setting required.

  • Therefore, the Beckhoff EL1862 provides plug-and-play installation for high-channel-count applications.

Input Signal Specifications

  • Specification: EN 61131-2, type 1/3 compliant.

  • "0" Signal Voltage: -3 to +5 V (type 1/3).

  • "1" Signal Voltage: 11 to 30 V (type 3).

  • Input Current: Typical 3 mA (type 3).

  • Input Filter: 3.0 milliseconds typical.

  • No Bouncing: Mechanical switches are debounced by the filter.

  • Signal Indication: LEDs show channel states.

  • Power Contacts: Connected through to subsequent terminals.

  • Thus, the EL1862 delivers reliable input detection with built-in debouncing.

Current Consumption and Isolation

  • Current Consumption (Power Contacts): 4 mA from 24 V supply (no power contacts).

  • Current Consumption (E-bus): Typical 100 mA.

  • Electrical Isolation: 500 V between E-bus and field potential.

  • Bit Width in Process Image: 16 inputs total.

  • Distributed Clocks: Not supported.

  • Field Power: Provided via power contacts from left side.

  • Therefore, the Beckhoff EL1862 consumes minimal power while providing robust isolation.

Flat-Ribbon Cable Connection

  • Connection Method: Flat-ribbon cable with insulation displacement.

  • Compatible Cables: Common flat-ribbon cables, AWG 28.

  • Connector Spacing: 1.27 mm pitch.

  • Contact Strip: 20-pin for secure connection.

  • Wiring Simplification: Significantly reduces wiring effort for many channels.

  • Alternative Cables: Special round cables also supported.

  • Stripping Length: Not required (IDC connection).

  • Solid Wiring: AWG 28 stranded wire via IDC.

  • Consequently, the EL1862 dramatically reduces installation time for multi-channel systems.

Housing and Mounting Data

  • Design Form: Compact terminal housing with signal LEDs.

  • Material: Polycarbonate.

  • Dimensions (W x H x D): 12 mm x 100 mm x 73 mm.

  • Mounting: 35 mm DIN rail conforming to EN 60715.

  • Locking: Built-in locking mechanism.

  • Side by Side Mounting: Double slot and key connection.

  • Marking: BZxxx series labeling compatible.

  • Protection Rating: IP20 with variable installation position.

  • Thus, the Beckhoff EL1862 fits in minimal panel space.

Temperature and Environmental Ratings

  • Operating Temperature: 0°C to +55°C.

  • Storage Temperature: -25°C to +85°C.

  • Relative Humidity: 95% maximum, no condensation.

  • Vibration Resistance: Conforms to EN 60068-2-6.

  • Shock Resistance: Conforms to EN 60068-2-27.

  • EMC Immunity: Conforms to EN 61000-6-2.

  • EMC Emission: Conforms to EN 61000-6-4.

  • Installation Position: Variable (any orientation).

  • Chemical Resistance: Avoid direct chemical exposure.

  • Moreover, the EL1862 withstands typical industrial environmental conditions.

Approvals and Certifications

  • CE: Certified.

  • UL: Certified.

  • ATEX: Approved (II 3 G Ex nA IIC T4 Gc).

  • EN 61131-2: Compliance with type 1/3 specifications.

  • Hazardous Location: Suitable for Zone 2 gas environments.

  • Safety Standard: Ex nA (non-sparking) protection.

  • Temperature Class: T4 (maximum surface temperature).

  • Gas Group: IIC (includes hydrogen and acetylene).

  • Therefore, the Beckhoff EL1862 is certified for use in hazardous locations.

Installation Guide

First, verify that all system power sources are completely disconnected. Then, mount the Beckhoff EL1862 onto a 35 mm DIN rail. Push the terminal down until the lock engages audibly. After that, connect the flat-ribbon cable to the 20-pin contact strip. Use AWG 28 flat-ribbon cable with 1.27 mm spacing. Press the cable into the insulation displacement contacts firmly. No stripping of wires is required. Then, connect the 24 V DC power supply to the power contacts. The power contacts pass through to adjacent terminals. After that, connect your 16 input field devices to the ribbon cable. Ensure the "1" signal voltage is between 11-30 V DC. The input filter provides 3 ms debouncing for mechanical switches. Then, connect the E-bus from the previous EtherCAT terminal. Apply power to the system. Finally, verify the 16 input LEDs indicate correct signal states. As a result, the Beckhoff EL1862 will provide reliable digital input acquisition.

Packaging List

  • One Beckhoff EL1862 EtherCAT digital input terminal

  • One 20-pin contact strip (installed)

  • One product identification label

  • One installation and configuration guide

  • One flat-ribbon cable connection example

Common FAQs

Q1: How many input channels does the Beckhoff EL1862 provide?
A: This terminal provides 16 digital input channels. Therefore, it suits high-density applications with many field devices. The signal states are indicated by LEDs.

Q2: What is the input filter time on the EL1862?
A: The typical input filter time is 3.0 milliseconds. Consequently, mechanical switch bounce is eliminated. This simplifies wiring by removing external debouncing components.

Q3: What type of cable does the Beckhoff EL1862 use?
A: This terminal uses flat-ribbon cable with AWG 28 conductors. The spacing is 1.27 mm with insulation displacement connection. Therefore, no stripping or special tools are required.

Q4: Is the EL1862 approved for hazardous locations?
A: Yes, this terminal has ATEX approval (II 3 G Ex nA IIC T4 Gc). Therefore, it is suitable for Zone 2 hazardous gas environments. Always follow local installation regulations.

Q5: What is the signal voltage range for the Beckhoff EL1862?
A: The "0" signal voltage is -3 to +5 V DC. The "1" signal voltage is 11 to 30 V DC. The nominal voltage is 24 V DC with -15%/+20% tolerance. Therefore, it complies with EN 61131-2 type 1/3 specifications.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap