Introduction:

The Siemens 3RW4423-1BC44 is a SIRIUS soft starter. It offers 36A standard or 62A inside-delta. Motor overload protection and PTC input included.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Siemens
Series: SIRIUS
Part Number: 3RW4423-1BC44
Type: Soft Starter (High Feature Applications)
Condition: Subject to stock check
Weight: 3.2
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The Siemens 3RW4423-1BC44 is a SIRIUS soft starter for high feature applications. This device reduces motor starting current and mechanical stress. It works with three-phase squirrel cage motors. The unit has an integrated bridging contact system and thyristors. Inside-delta circuit connection allows higher power output. Screw terminals make wiring simple and secure.

For inquiries, contact us at +86 158 8020 0923 (WhatsApp).

Part Number Breakdown (Tree Structure)

  • 3RW44 → SIRIUS soft starter series
    • High feature application family
  • 23 → Current rating
    • 36A standard operation
    • 62A inside-delta operation
  • 1BC44 → Voltage and control version
    • 200-460V AC main circuit
    • 230V AC control supply
    • Screw terminals

Current Ratings (Standard Circuit)

  • At 40°C: 36 Amps
  • At 50°C: 32 Amps
  • At 60°C: 29 Amps

Current Ratings (Inside-Delta Circuit)

  • At 40°C: 62 Amps
  • At 50°C: 55 Amps
  • At 60°C: 50 Amps

Power Ratings (Standard Circuit at 40°C)

  • At 230V: 7.5 kW (10 hp)
  • At 400V: 18.5 kW

Power Ratings (Inside-Delta at 40°C)

  • At 230V: 18.5 kW (20 hp)
  • At 400V: 30 kW

Operating Voltage and Frequency

  • Standard Circuit Voltage: 200 to 460 V AC
  • Inside-Delta Voltage: 200 to 460 V AC
  • Voltage Tolerance: -15% to +10%
  • Operating Frequency: 50 to 60 Hz
  • Frequency Tolerance: -10% to +10%

Control Supply Voltage

  • Type: AC only
  • Voltage: 230 V AC
  • Frequency: 50 Hz or 60 Hz
  • Voltage Tolerance: -15% to +10%

Protection Functions

  • Intrinsic Device Protection: Yes
  • Motor Overload Protection: Yes
  • Thermal Resistor Evaluation: Yes (PTC input)
  • Adjustable Current Limitation: Yes
  • External Reset: Yes
  • Minimum Load: 8% of I_M
  • Adjustable Motor Current Range: 7A to rated current
  • Continuous Operating Current: 115% of I_e at 40°C
  • Typical Active Power Loss: 10 W at operating current

Product Components and Features

  • Integrated Bridging Contact System: Yes
  • Thyristors: Yes
  • Inside-Delta Circuit: Yes
  • Output for Engine Brake: Yes
  • Fault Display: Visual display on unit

Auxiliary Contacts

  • NC Contacts: 0
  • NO Contacts: 3
  • Changeover Contacts: 1
  • UL Contact Rating: B300 / R300

Dimensions and Weight

  • Width: 170 mm
  • Height: 192 mm
  • Depth: 270 mm
  • Weight: 3.20 kg (approx.)

Mounting Specifications

  • Mounting Type: Screw fixing
  • Mounting Position: ±90° rotatable on vertical plane
  • Tilt Angle: ±22.5° forward and backward
  • Protection Class: IP00
  • Max Installation Altitude: 5,000 meters above sea level
  • Max Cable Length: 500 meters
  • Number of Main Circuit Poles: 3

Clearance Requirements

  • Upwards Clearance: 100 mm minimum
  • Sideways Clearance: 5 mm minimum
  • Downwards Clearance: 75 mm minimum

Ambient Conditions

  • Max Operating Temperature: 60°C
  • Storage Temperature: -25°C to +80°C
  • Derating Start Temperature: 40°C
  • Protection Class: IP00 (open enclosure)

Main Circuit Connections (Box Terminals)

Front Clamping Point (Single Wire):

  • Solid: 2.5 to 16 mm²
  • Finely stranded with ferrule: 2.5 to 35 mm²
  • Finely stranded without ferrule: 4 to 50 mm²
  • Stranded: 4 to 70 mm²
  • AWG: 10 to 2/0

Back Clamping Point (Single Wire):

  • Solid: 2.5 to 16 mm²
  • Finely stranded with ferrule: 2.5 to 50 mm²
  • Without ferrule: 10 to 50 mm²
  • Stranded: 10 to 70 mm²
  • AWG: 10 to 2/0

Both Clamping Points (Two Wires):

  • Solid: 2x (2.5 to 16 mm²)
  • Finely stranded with ferrule: 2x (2.5 to 35 mm²)
  • Without ferrule: 2x (4 to 35 mm²)
  • Stranded: 2x (4 to 50 mm²)
  • AWG: 2x (10 to 1/0)

Auxiliary Circuit Connections

  • Connection Type: Screw-type terminals
  • Solid Wire: 2x (0.5 to 2.5 mm²)
  • Finely stranded with ferrule: 2x (0.5 to 1.5 mm²)
  • AWG: 2x (20 to 14)

UL/CSA Ratings (50°C)

Standard Circuit (hp):

  • 200/208V: 10 hp
  • 220/230V: 10 hp
  • 460/480V: 20 hp

Inside-Delta Circuit (hp):

  • 200/208V: 15 hp
  • 220/230V: 20 hp
  • 460/480V: 40 hp

Installation Guide

  • Turn off all power before installation.
  • Mount the soft starter on a vertical flat surface.
  • Use four screws through the mounting holes.
  • Keep 100 mm clearance above for cooling air.
  • Keep 75 mm clearance below for cooling air.
  • Do not block the side ventilation openings.
  • Connect main supply to L1, L2, L3 input terminals.
  • Connect motor leads to T1, T2, T3 output terminals.
  • Wire control supply 230V AC to A1 and A2 terminals.
  • Connect external reset button if needed.
  • Wire PTC thermistor to the dedicated input.
  • Use proper torque for all screw terminals.
  • Do not exceed 500 meters cable length between soft starter and motor.

Application Scenarios

  • Pumps and centrifugal pumps for smooth starting
  • Fans and blowers to reduce belt stress
  • Conveyors for gentle material handling
  • Compressors to limit inrush current
  • Mixers and agitators with high inertia loads
  • Crushers and mills needing adjustable torque

Package Contents

  • One Siemens 3RW4423-1BC44 SIRIUS soft starter
  • One quick start guide
  • One CD with full manual and parameter software
  • Terminal screws (pre-installed)

Warranty and Shipping

  • 12 months factory warranty from shipment date.
  • Warranty covers manufacturing defects only.
  • Overvoltage or wrong wiring voids the warranty.
  • Shipping options: FedEx, UPS, DHL.
  • Tracking number provided after shipment.

Frequently Asked Questions (FAQ)

Q1: What is the difference between standard and inside-delta connection on the 3RW4423-1BC44?

Standard connection gives 36A and 18.5kW at 400V. Inside-delta connection gives 62A and 30kW at 400V. Inside-delta uses the motor’s internal windings to reduce current per thyristor.

Q2: Does this soft starter have motor overload protection built in?

Yes, the Siemens 3RW4423-1BC44 has built-in motor overload protection. It also evaluates PTC thermistor inputs. External reset is available for convenience.

Q3: What control supply voltage does the 3RW4423-1BC44 need?

This model needs 230V AC control supply. Frequency can be 50 Hz or 60 Hz. The tolerance range is -15% to +10% of nominal voltage.

Q4: What is the maximum operating temperature for this soft starter?

Maximum operating temperature is 60°C. However, current derating starts at 40°C. At 60°C, standard current rating drops to 29A from 36A.

Q5: How much clearance do I need around the 3RW4423-1BC44?

You need 100 mm clearance above the unit. You need 75 mm clearance below. Side clearance is only 5 mm. These gaps allow proper cooling airflow.

Buying Guide

When you buy a Siemens 3RW4423-1BC44 soft starter, follow these tips. First, check your motor power. Standard circuit suits 18.5kW motors. Inside-delta circuit suits 30kW motors. Second, verify your supply voltage. This unit works from 200V to 460V AC. Third, confirm your control voltage. You need 230V AC for the electronics. Fourth, measure your panel space. The unit is 170mm wide, 192mm tall, and 270mm deep. Fifth, plan your clearances. Allow 100mm above and 75mm below. Sixth, check your ambient temperature. Derating starts at 40°C. Seventh, consider your cable length. Maximum is 500 meters. Eighth, review warranty terms. We offer 12 months coverage. Ninth, choose your shipping method. We use FedEx, UPS, and DHL. Finally, test the soft starter with your motor before full production.

Copyright © 2026 PLCDCS HUB Limited. All rights reserved.
Original Source: https://plcdcshub.com/
Partner: Powergear X Automation Limited
Oiltech Controls Limited

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap