+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

Schneider Electric 140ARI03010C Quantum Analog Input 8 Channel

Introduction:

The Schneider Electric 140ARI03010C is an 8-channel analog input module for Modicon Quantum. It features differential inputs with 13-bit resolution for RTD sensors.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Schneider Electric
Series: Modicon Quantum
Part Number: 140ARI03010C
Type: Analog Input Module
Condition: Subject to stock check
Weight: 0.46
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Introduction to the Schneider Electric 140ARI03010C Analog Module

The 140ARI03010C from Schneider Electric belongs to the Modicon Quantum automation platform. This analog input module processes signals from resistance temperature detectors (RTDs). Engineers use the 140ARI03010C for precise temperature measurement in industrial processes. Its 8 differential channels provide excellent noise immunity for accurate readings. Additionally, the module supports multiple RTD types for flexible sensor selection.

Input Channel Specifications

The 140ARI03010C offers 8 analog input channels. Each channel uses differential input configuration for enhanced accuracy. Differential inputs reject common mode noise effectively. Input impedance measures at least 10 MOhm for minimal signal loading. Addressing requires 9 input words for complete data mapping. Therefore, the 140ARI03010C delivers reliable signal acquisition from remote sensors.

Supported RTD Types

This module supports a wide range of RTD temperature probes. Pt100 sensors cover -200°C to +850°C and 100°C to 450°C ranges. Pt200, Pt500, and Pt1000 sensors are also compatible. Ni100 and Ni200 probes cover -60°C to +180°C. Ni500 and Ni1000 sensors work with 0.5 mA excitation. Pt100, Pt200, Ni100, and Ni200 operate with 2.5 mA excitation. Consequently, the 140ARI03010C handles most industrial RTD temperature measurement needs.

Resolution and Accuracy

Input resolution reaches 13 bits for precise signal conversion. Absolute accuracy error stays within 0.1°C for temperature readings. Linearity error measures ±0.01% of full scale or ±0.5°C. Accuracy drift depends on ambient temperature conditions. At 25°C (77°F), drift stays within ±0.5°C. From 0°C to 60°C (32°F to 140°F), drift reaches ±0.9°C. Therefore, the 140ARI03010C maintains high accuracy across its operating range.

Update Time and Wiring

Update time varies with wiring configuration. For 3-wire RTD connections, update time is 1200 ms. For 2-wire or 4-wire connections, update time is 640 ms. Users can select the optimal wiring method for each application. Longer update times provide better noise rejection. Shorter update times suit faster process requirements. Consequently, the 140ARI03010C adapts to various response time needs.

Isolation Specifications

Isolation between channels and the bus reaches 1780V AC at 47-63 Hz for 60 seconds. DC isolation between channels and bus is 2500V for 60 seconds. Isolation between individual channels reaches 300Vrms AC. These high isolation ratings protect the controller from field wiring faults. Therefore, the 140ARI03010C provides safe operation in industrial environments.

Fault Detection

The 140ARI03010C includes comprehensive fault detection features. Broken wire detection alerts operators to sensor failures. Overtacking scale detection identifies out-of-range signals. Each channel has independent fault monitoring. The module reports faults to the controller for appropriate action. Consequently, maintenance teams receive early warnings of sensor issues.

Local Signaling

Local signaling uses multiple LEDs for status indication. One green LED shows bus communication is present (Active). One red LED indicates an external fault condition. Eight green LEDs show individual channels are active. Eight red LEDs indicate channel-specific faults. This comprehensive LED array allows quick visual diagnostics. Therefore, operators can assess module status without special tools.

Power and Dissipation

Bus current requirement for the 140ARI03010C is 200 mA. Power dissipation measures only 1 watt under normal operation. This low dissipation minimizes heat buildup in the rack. The module fits in standard Quantum rack slots. Therefore, multiple analog modules can be installed without overheating concerns.

Protective Treatment

The 140ARI03010C features conformal coating protection. The coating uses Humiseal 1A33 material for durability. This coating protects circuit boards from moisture and contaminants. It resists dust, chemicals, and humidity ingress. Therefore, the module operates reliably in harsh industrial environments.

Physical Characteristics

The 140ARI03010C follows the standard Modicon Quantum module format. Net weight measures 0.7 lb (US) or 0.3 kg. Package dimensions are 2.0 x 6.5 x 12.2 inches (5.0 x 16.5 x 31.0 cm). The module carries CE marking for European compliance. GTIN barcode is 3595860003430 for global tracking. Returnability is not available for this model.

Environmental Specifications

Operating ambient temperature ranges from 32°F to 140°F (0°C to 60°C). Storage temperature spans -40°F to 185°F (-40°C to 85°C). Relative humidity tolerance reaches 95% without condensation. Operating altitude is acceptable up to 16,404 feet (5,000 meters). Consequently, the 140ARI03010C suits most industrial environments worldwide.

Standards and Certifications

The 140ARI03010C complies with UL 508 and CSA C22.2 No 142 standards. Product certifications include FM Class 1 Division 2 for hazardous locations. cUL certification provides Canadian market approval. The module meets RoHS compliance for environmental responsibility. Resistance to electrostatic discharge reaches 4 kV contact and 8 kV air per IEC 801-2. Resistance to electromagnetic fields reaches 9.1 V/m (10 V/m) from 80 to 1000 MHz per IEC 801-3.

Installation Guidelines

Follow these steps to install the 140ARI03010C correctly.

  1. Power Down the Rack: Ensure the Quantum rack is completely de-energized. Lock out the main power source for safety.

  2. Insert the Module: Slide the 140ARI03010C into an available Quantum rack slot. Push firmly until the module seats properly.

  3. Secure the Module: Tighten the retaining screws at the top and bottom. Use a screwdriver to lock the module in place.

  4. Wire RTD Sensors: Connect RTD leads to the input terminals. Use 2-wire, 3-wire, or 4-wire configuration as needed.

  5. Configure Inputs: Set up each channel for the correct RTD type. Use programming software to select Pt100, Ni100, or other sensor types.

  6. Power Up: Apply system power and monitor the status LEDs. The 140ARI03010C is ready when the green Active LED illuminates.

Package Contents

Your 140ARI03010C shipment includes the following items:

  • One Schneider Electric 140ARI03010C analog input module

  • One installation instruction sheet

  • One set of terminal number labels

  • One anti-static protective bag

Common FAQs

1. Can the 140ARI03010C accept 4-20 mA analog signals?
No, the 140ARI03010C is designed for RTD temperature sensors only. For 4-20 mA signals, select a different Quantum analog module.

2. What is the difference between 2-wire, 3-wire, and 4-wire RTD connections?
2-wire connections are simplest but least accurate. 3-wire and 4-wire connections compensate for lead resistance. The 140ARI03010C supports all three wiring methods.

3. How do I know if an RTD sensor has a broken wire?
The 140ARI03010C automatically detects broken wires. The channel’s red fault LED will illuminate when a broken wire is detected.

4. What is the purpose of the conformal coating on this module?
The Humiseal 1A33 conformal coating protects the 140ARI03010C from moisture, dust, and chemical contamination. It extends module life in harsh environments.

5. Can I mix different RTD types on the same module?
Yes, each channel of the 140ARI03010C is independently configurable. You can connect Pt100, Ni100, and other RTD types on a single module.

Conclusion

The Schneider Electric 140ARI03010C delivers precise RTD temperature measurement for Modicon Quantum systems. Its 8 differential channels provide excellent noise immunity and accuracy. Wide support for Pt and Ni RTD types offers flexible sensor selection. Comprehensive fault detection and isolation ensure reliable operation. For analog temperature input applications, choose the 140ARI03010C module.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap