Meggitt Vibro-Meter 111-412-000-013 Ex Proximity System M10x1


Introduction:
Meggitt Vibro-Meter 111-412-000-013 Ex proximity system. 8mm probe, M10x1 thread, 1m integral cable, 5m total length. IP68, -40 to +180°C. API 670.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Meggitt Vibro-Meter 111-412-000-013 Ex Certified Proximity Measuring System
The Meggitt (Vibro-Meter) 111-412-000-013 is an Ex certified proximity measuring system. This device uses the eddy-current principle for non-contact measurement. You can use it in potentially explosive atmospheres. It works for shaft relative vibration monitoring. This system also handles gap and position measurement in hazardous areas.
Technical Specifications of the 111-412-000-013 Ex Version
The Meggitt (Vibro-Meter) 111-412-000-013 with option A2 is certified for explosive environments. The transducer requires a high-frequency power source. This comes from an IQS900 signal conditioner. The transducer is an 8 mm wire coil construction. The tip is made of Torlon (polyamide-imide). The body is encapsulated in stainless steel AISI 316L with high-temperature epoxy glue.
Mechanical Configuration
The body thread on the Meggitt (Vibro-Meter) 111-412-000-013 is M10 x 1. This provides standard metric mounting. The integral cable length is 1.0 meter with ±100 mm tolerance. The total system length is 5 meters. The cable uses FEP covered 70 Ohm coaxial type. The cable diameter is 3.6 mm.
Hazardous Area Certification
The environment code A2 indicates explosive Ex i certification. This allows the Meggitt (Vibro-Meter) 111-412-000-013 to operate in hazardous locations. Always follow local regulations for installation in explosive atmospheres. Use only approved signal conditioners for Ex applications.
Connector Specifications
The connectors are self-locking miniature coaxial type. Hand-tighten these connectors until locked. Do not use tools for tightening. This model has no optional protection (F0) and no flexible hose (G000).
Temperature Ranges for Ex Zone Use
For Ex Zone use, the transducer and cable operate from -40°C to +195°C. The transducer alone operates from -40°C to +180°C with drift below 5%. Short-term survival from +180°C to +220°C has drift above 5%. The cable and connector operate from -40°C to +200°C.
Environmental Ratings
The head of the proximity transducer is rated IP68. This includes the transducer tip and integral cable. Vibration tolerance is 5g peak between 10 and 500 Hz. Shock acceleration tolerance is 15g peak. This uses a half sine-wave with 11 ms duration.
Measurement and Performance
The frequency response goes from DC to 20 kHz at -3 dB. The measurement range options are 2 mm or 4 mm. The system offers voltage or current output with short circuit protection. The design is temperature-compensated for stable readings. This system conforms to API 670 recommendations.
Installation Guidelines for the 111-412-000-013 Ex Version
Mount the Meggitt (Vibro-Meter) 111-412-000-013 using the M10 x 1 thread. Hand-tighten all coaxial connectors until locked. Keep the probe tip clean for accurate measurements. Use only with Ex certified IQS900 signal conditioners. Follow all hazardous area installation requirements. This system is ideal for VM600Mk2, VM600, and VibroSmart monitoring systems in hazardous locations.
Package Contents
One (1) Meggitt (Vibro-Meter) 111-412-000-013 Ex certified proximity transducer with 1.0m integral cable
Ex certification documentation and mounting instructions
Common FAQs for the 111-412-000-013 Ex Version
1. What is the body thread size on this model?
The Meggitt 111-412-000-013 has an M10 x 1 body thread. This provides standard metric mounting for many industrial applications.
2. What are the cable lengths for this system?
The Meggitt 111-412-000-013 has a 1.0 meter integral cable. The total system length is 5 meters.
3. What does the A2 environment code indicate?
The A2 code on the Meggitt 111-412-000-013 indicates explosive Ex i certification. This allows use in potentially explosive atmospheres.
4. What is the operating temperature range for Ex Zone use?
For Ex Zone use, the Meggitt 111-412-000-013 transducer and cable operate from -40°C to +195°C.
5. Is this system compliant with API 670 standards?
Yes, the Meggitt 111-412-000-013 conforms to API 670 recommendations. This makes it suitable for machinery protection systems in hazardous areas.
Why Choose the Meggitt Vibro-Meter 111-412-000-013 Ex Version?
This Ex certified proximity measuring system delivers reliable eddy-current sensing for hazardous areas. The M10 x 1 thread provides easy mounting in standard ports. The API 670 compliance ensures suitability for critical turbomachinery protection. The wide temperature range and IP68 rating handle harsh conditions. Order the Meggitt (Vibro-Meter) 111-412-000-013-A2-B1-E010-F0-G000-H05 today for your hazardous area vibration monitoring needs.
Welcome to learn about our business. We are a leading global provider of automation equipment and will provide you with complete and cost-effective product solutions. You are welcome to choose us, and our services will make you a long-term partner like our other customers.
Now please let us know your needs and suggestions.
About Ubest
Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.
Product Center
Contact Us
Phone:+86 180 3000 5825
Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China
Email: [email protected]
Contact: Klaus
Industry Links