Introduction:
GE Fanuc IC660BBR100 normally closed relay output block. 16 outputs in 4 isolated groups, AC/DC operation, Genius I-O series.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
GE Fanuc IC660BBR100 – Normally Closed Relay Output Block for Genius I-O Systems
The GE Fanuc IC660BBR100 is a normally closed relay output block. Specifically, this block belongs to the Genius I-O product family. It provides 16 output circuits in total. Furthermore, these outputs are arranged in four independent groups. Each group contains four relay-type outputs. Consequently, this block suits low-power control and indicating device applications.
Output Configuration and Group Isolation
Number of Outputs: 16 circuits total.
Output Configuration: 4 groups of 4 outputs each.
Output Block Type: Normally closed.
Normal State: Remains conductive when de-energized.
Group to Group Isolation: 1500 VAC rating.
Output Voltage Type: AC or DC per group.
Output Voltage Range (AC): 5 to 250 VAC.
Output Voltage Range (DC): 5 to 220 VDC.
Therefore, the IC660BBR100 provides flexible output grouping with high isolation.
Normally Closed Operation
Behavior: Contacts remain closed when de-energized.
Contrast: Different from normally open blocks.
Application Suitability: Failsafe control schemes.
Power Loss Response: Outputs stay conductive.
De-energized State: Default conductive condition.
Energized State: Contacts open when coil is powered.
Thus, the GE Fanuc IC660BBR100 suits applications requiring failsafe operation.
Power Requirements and Voltage Selection
Power Requirements: 87 milliamps at 115 Volts AC.
Factory Voltage Settings: 115 VAC or 230 VAC optional.
Voltage Selection Method: Jumpers on terminal assembly.
Field Adjustable: Yes, via jumper configuration.
Operating Voltage Range: Wide compatibility.
Power Source: Each group can have separate AC or DC source.
Consequently, the IC660BBR100 adapts to various plant power standards.
Customization and Configuration Features
Handheld Monitor: Used for behavior customization.
Output Power-Up Defaults: User configurable.
Communication Interruption Behavior: Selectable hold last state or revert to factory settings.
CPU Redundancy Type: Selectable by user.
Bus Switching Module Control: Designation available.
Flexibility: Adapts to different system architectures.
Therefore, the GE Fanuc IC660BBR100 supports sophisticated control strategies.
Compatible Devices and Applications
Lamps: Low-power indicator lighting.
Contactors: Motor and load switching.
Relays: Interposing and control relays.
Device Voltage Range: 5-220 VDC or 5-250 VAC.
Power Level: Low-power control applications.
Industry: Industrial automation and process control.
Thus, the IC660BBR100 interfaces with many standard field devices.
LED Indicators and Diagnostics
LED Location: In the block’s chassis.
Unit Conditions: Signaled by LEDs.
I/O Conditions: Monitored via LEDs.
Blinking LED: Indicates circuit fault.
OFF (Dark): Suggests defective block or missing power supply.
ON Status: Confirms expected performance.
Consequently, operators can quickly diagnose block status.
Temperature and Environmental Ratings
Operating Temperature Range: 32°F to 140°F (0°C to 60°C).
Storage Temperature Range: -40°F to 212°F (-40°C to 100°C).
Operating Humidity: 5% to 95% non-condensing.
Storage Humidity: 5% to 95% non-condensing.
Application Environment: Industrial control panels.
Durability: Suitable for typical manufacturing environments.
Moreover, the GE Fanuc IC660BBR100 operates reliably in normal industrial conditions.
Physical Dimensions and Weight
Dimensions (H x W x D): 8.8 x 3.3 x 3.9 inches.
Weight: 4 pounds (1.81 kg).
Mounting: Standard Genius I-O block mounting.
Form Factor: Compact for panel installation.
Construction: Rugged industrial design.
Therefore, the IC660BBR100 fits standard Genius I-O racks and panels.
Installation Guide
First, verify that all power sources are disconnected. Then, select the appropriate voltage setting (115 VAC or 230 VAC) using jumpers on the terminal assembly. After that, mount the GE Fanuc IC660BBR100 into the Genius I-O block mounting location. Next, connect the AC or DC power sources to each of the 4 output groups. Each group can have its own separate power supply. Then, connect your field devices (lamps, contactors, relays) to the 16 output circuits. Ensure device voltage falls within 5-250 VAC or 5-220 VDC range. Subsequently, configure output power-up defaults using a handheld monitor. Set the behavior for communication interruption (hold last state or factory defaults). Select CPU redundancy type if required. Then, apply power to the block. Verify the ON LED illuminates for normal operation. Finally, test each output circuit for proper switching. As a result, the GE Fanuc IC660BBR100 will provide reliable normally closed relay outputs.
Packaging List
One GE Fanuc IC660BBR100 normally closed relay output block
One terminal assembly with voltage selection jumpers
One product identification label
One installation and configuration guide
One handheld monitor reference card
Common FAQs
Q1: What does “normally closed” mean for the IC660BBR100?
A: Normally closed means the relay contacts remain conductive when de-energized. Therefore, the output is ON when the block loses power. This differs from normally open blocks which turn OFF.
Q2: How many output circuits does the GE Fanuc IC660BBR100 provide?
A: This block provides 16 output circuits total. Specifically, these are arranged in 4 independent groups. Each group contains 4 relay outputs with 1500 VAC isolation between groups.
Q3: What voltage ranges does the IC660BBR100 support?
A: The block supports AC voltages from 5 to 250 VAC. It also supports DC voltages from 5 to 220 VDC. Each output group can have its own separate AC or DC power source.
Q4: How do I configure the IC660BBR100 for my application?
A: Use a handheld monitor for configuration. You can set output power-up defaults and behavior during communication loss. CPU redundancy type and bus switching module control are also selectable.
Q5: What does a blinking LED indicate on the GE Fanuc IC660BBR100?
A: A blinking LED indicates a circuit fault. An OFF (dark) LED suggests a defective block or missing power supply. An ON LED confirms normal expected performance.