Allen-Bradley 1747-C10 Programming Cable SLC 500 6ft RJ-45



Introduction:
The 1747-C10 is a 6-foot programming cable for SLC 500 controllers. It has an RJ-45 connector for reliable communication with peripheral devices.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Allen-Bradley 1747-C10 is a programming and communication cable for SLC 500 controllers. This cable measures 6 feet in length. It uses an RJ-45 connector for efficient connectivity. The cable works with programming and communication peripherals. It also serves as a replacement cable for existing systems. This cable ensures reliable communication between your controller and programming devices.
For inquiries, contact us at +86 158 8020 0923 (WhatsApp).
Part Number Breakdown (Tree Structure)
- 1747 → Series Family
- SLC 500 controller family
- Allen-Bradley / Rockwell Automation
- C → Product Type
- Cable product category
- 10 → Specific Model
- 6 foot programming cable
- RJ-45 connector type
Key Specifications
- Brand: Allen-Bradley / Rockwell Automation
- Part Number: Allen-Bradley 1747-C10
- Series: SLC 500
- Product Type: Programming and Communication Cable
- Cable Length: 6 feet (1.8 meters)
- Connector Type: RJ-45
- Replacement Cable: Yes
Compatibility
- Compatible with SLC 500 controllers
- Supports programming peripheral devices
- Supports communication peripheral devices
- Works with SLC 500 programming software
- Use as direct replacement for existing cables
Environmental Specifications
- Operating Temperature: 32°F to 140°F (0°C to 60°C)
- Storage Temperature: -40°F to 185°F (-40°C to 85°C)
- Relative Humidity: 5% to 95% non-condensing
Key Features
- 6-foot length provides flexible positioning.
- RJ-45 connector ensures secure connection.
- Works with SLC 500 programming peripherals.
- Suitable for industrial environments with wide humidity range.
- Durable construction for long-term use.
- Can be stored in extreme temperatures when not in use.
Applications
- Connect programming terminal to SLC 500 CPU
- Download ladder logic programs to controller
- Upload program backups from SLC 500
- Monitor real-time controller data
- Replace damaged or lost programming cables
- Set up spare programming stations
Installation and Use Guide
- Turn off power to the SLC 500 controller first.
- Insert the RJ-45 connector into the controller’s programming port.
- Connect the other end to your programming device.
- Ensure both ends click securely into place.
- Do not force the connector into the port.
- Route the cable away from high-voltage wires.
- Avoid sharp bends or kinks in the cable.
- Use cable ties to secure loose cable length.
- Disconnect by pulling the connector body, not the cable.
Maintenance Tips
- Inspect RJ-45 connectors for bent pins before use.
- Clean connectors with compressed air if dusty.
- Check for cuts or damage to the cable jacket.
- Store the cable in a dry place when not in use.
- Do not expose to direct sunlight for long periods.
- Replace the cable if communication becomes intermittent.
Troubleshooting Tips
- If communication fails, check both connector ends.
- Verify the RJ-45 plug is fully seated in the port.
- Test the cable with another SLC 500 controller.
- Check your programming software settings.
- Ensure the correct COM port is selected.
- Try a different programming device if available.
Package Contents
- One Allen-Bradley 1747-C10 programming cable (6 feet)
- RJ-45 connectors on both ends (molded)
Warranty and Shipping
- 12 months factory warranty from shipment date.
- Warranty covers manufacturing defects only.
- Physical damage or improper use voids the warranty.
- Shipping options: FedEx, UPS, DHL.
- Tracking number provided after shipment.
Frequently Asked Questions (FAQ)
Q1: What is the length of the 1747-C10 cable?
The Allen-Bradley 1747-C10 cable is 6 feet (1.8 meters) long. This length allows flexible positioning of your programming device. It is long enough for most workbench and panel setups.
Q2: What connector type does this cable use?
This cable uses RJ-45 connectors on both ends. This is the same type as standard Ethernet cables. However, the pinout is specific to Allen-Bradley SLC 500 controllers.
Q3: Can I use a standard Ethernet cable instead of the 1747-C10?
No, a standard Ethernet cable will not work correctly. The 1747-C10 has a specific wiring pinout for SLC 500 communication. Using a standard cable may damage your controller or fail to communicate.
Q4: What temperature range can this cable handle?
Operating temperature range is 32°F to 140°F (0°C to 60°C). Storage temperature range is -40°F to 185°F (-40°C to 85°C). Humidity range is 5% to 95% non-condensing.
Q5: Is the 1747-C10 compatible with all SLC 500 models?
Yes, this cable works with all SLC 500 controller models. It connects to the programming port on the CPU. It also works with communication peripheral devices for the SLC 500 series.
Buying Guide
When you buy an Allen-Bradley 1747-C10 programming cable, follow these tips. First, verify your controller type. This cable works with SLC 500 only. Second, check your programming device port. Ensure it accepts RJ-45 connections. Third, measure your required distance. This 6-foot cable suits most workstations. Fourth, consider buying a spare cable for backup. Fifth, check your environment temperature. The cable works from 32°F to 140°F. Sixth, avoid high humidity areas above 95%. Seventh, inspect your existing cable for damage before replacement. Eighth, verify your programming software version works with this cable. Ninth, review warranty terms. We offer 12 months coverage. Tenth, choose your shipping method. We use FedEx, UPS, and DHL. Finally, test the cable immediately after receiving it to ensure proper communication.
Copyright © 2026 PLCDCS HUB Limited. All rights reserved.
Original Source: https://plcdcshub.com/
Partner: Powergear X Automation Limited
Oiltech Controls Limited