3500/94M-01-00-00 | Bently Nevada 10″ VGA Display Module



Introduction:
Bently Nevada 3500/94M-01-00-00 VGA display module with 10-inch face-mount screen, 4.6 W power draw, and -20°C to 65°C operating range for 3500 racks.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Bently Nevada 3500/94M-01-00-00 is a VGA Display Module for industrial control and automation applications.
What Is the Bently Nevada 3500/94M-01-00-00 VGA Display Module?
The Bently Nevada this module is a VGA display module for rack-mounted 3500 monitor systems. It provides a 10-inch face-mount display and draws 4.6 watts maximum, making it a practical operator interface for machinery protection racks in oil and gas facilities.
This module is part of the 3500 series and is built for demanding environments where reliable visual status indication is mission-critical. The face-mount configuration fits directly into a full-height front slot of a rack-mounted 3500 monitor, so operators can read monitor status, data, and values without opening the cabinet.

Key Specifications at a Glance
- Input voltage: 24 Vdc power out via front port; VGA signal out and touch commands in through the same front port.
- Power consumption: 4.6 watts maximum.
- Operating temperature: -20°C to 65°C (-22°F to 149°F).
- Storage temperature: -40°C to 85°C (-40°F to 185°F).
- Humidity: 95%, non-condensing.
- Display size and mounting: 10-inch display, face mount (option 01).
- Weight: 1.07 kg (module and I/O combined).
- Compliance: FCC Part 15; EMC standards EN 61000-6-2 and EN 61000-6-4; electrical safety CSA C22.2 61010-1 and UL EN 61010-1; RoHS Directive 2011/65/EU.
The operating temperature range of -20°C to 65°C is a key advantage for field-mounted racks in upstream and midstream service, where ambient conditions can swing widely. Because the module is rated for 95% non-condensing humidity, it suits humid climates when installed in a suitable enclosure.
How Does this module Integrate with a 3500 Rack?
Integration requires specific firmware, software, and hardware. The 3500/94M requires the 3500/22 Transient Data Interface (TDI) module. It also requires these or newer versions of the following firmware and software:
- 3500/94M Firmware 4.06, Rev. C
- 3500/22 Firmware (TDI) Rev 1.71
- 3500/01 Software (Rack Config) Rev 5.6
- 3500/02 Software (Op Display) Rev 2.21
- 3500/03 Software (Data Acquisition) Rev 1.22
The module occupies one full-height front slot in the monitor rack, while the associated I/O module uses one full-height rear slot. The front port provides 24 Vdc power out, VGA signal out, and touch commands in. A separate RS232 port handles touch controller data, and a VGA port delivers analog red, green, blue, and sync signals to the display.
Two front-panel LEDs support quick diagnostics: the OK LED indicates proper operation of the module, and the TX/RX LED indicates communications between other system modules. These indicators help field technicians confirm module health during routine rounds without connecting a laptop.

Which Environments Suit This Display Module?
this module is built for demanding environments in oil and gas operations. Typical applications include compressor stations, pipeline pump stations, and refinery rotating equipment trains where continuous machinery protection is required. The wide operating temperature range supports installation in cabinets exposed to seasonal temperature swings.
Because the module is face-mounted, operators can view status and values directly from the rack front. This arrangement reduces the need to open cabinet doors for routine checks, which helps maintain enclosure integrity in dusty or humid locations. For hazardous areas, the module itself is not rated for Class I, Division 2; the separate KVM Extender Receiver carries that approval in North America, while the transmitter must be installed in a safe area or approved enclosure.
What Should Buyers Verify Before Ordering?
First, confirm that your rack is a rack-mounted 3500 monitor, since the 10-inch face-mount display option is only available for that configuration. Second, verify that your system includes the 3500/22 TDI module and that firmware and software meet the minimum revisions listed above. Third, check the ordering options: this part number specifies no KVM extender and display router box cables (00) and no agency approval option (00).
Finally, review physical dimensions for panel planning. The display module measures 241.3 mm x 24.4 mm x 241.8 mm (9.5 in x 0.96 in x 9.52 in) and weighs 0.73 kg (1.6 lb). The I/O module measures 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) and weighs 0.34 kg (0.75 lb). Combined weight is 1.07 kg.
Frequently Asked Questions
What are the power requirements for the Bently Nevada 3500/94M-01-00-00?
The Bently Nevada 3500/94M-01-00-00 draws 4.6 watts maximum. Its front port provides 24 Vdc power out along with VGA signal out and touch commands in.
What is the operating temperature range of the 3500/94M-01-00-00?
The 3500/94M-01-00-00 operates from -20°C to 65°C (-22°F to 149°F) and stores from -40°C to 85°C (-40°F to 185°F). Humidity tolerance is 95%, non-condensing.
Which hardware and firmware does the 3500/94M-01-00-00 require?
The 3500/94M-01-00-00 requires the 3500/22 Transient Data Interface (TDI) module. It also needs 3500/94M Firmware 4.06 Rev. C, 3500/22 Firmware Rev 1.71, 3500/01 Software Rev 5.6, 3500/02 Software Rev 2.21, and 3500/03 Software Rev 1.22, or newer versions.
What does the 3500/94M-01-00-00 ordering option 01 specify?
Option 01 on the 3500/94M-01-00-00 specifies a 10-inch display with face mounting, available only for rack-mounted 3500 monitors. This part number also includes no KVM extender cables (00) and no agency approval option (00).
Is the 3500/94M-01-00-00 certified for hazardous areas?
The 3500/94M-01-00-00 itself is not certified for hazardous areas. The associated KVM Extender Receiver is approved for Class I, Division 2 in North America, but the transmitter must be installed in a safe area or approved enclosure.
Why Choose PetroPartsOnline for Bently Nevada Parts?
PetroPartsOnline supplies industrial automation and oil and gas parts with a focus on reliable sourcing for critical operations. Our team can help you confirm that this module matches your rack configuration and firmware baseline. We also provide application-specific selection guidance for related 3500 series modules and accessories.
Contact PetroPartsOnline for parts suited to your application’s requirements. Please verify current lifecycle status and availability with PetroPartsOnline before ordering.