Bently Nevada 200151-40-02-02 Accelerometer Cable 4m
Introduction:
The Bently Nevada 200151-40-02-02 is a 4.0 meter accelerometer standard cable with molded connectors and IP67 protection.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Introduction to the Bently Nevada 200151-40-02-02 Cable
The 200151-40-02-02 from Bently Nevada is an accelerometer interface standard cable. This cable features connectors on both ends for easy installation. Engineers use the 200151-40-02-02 to connect accelerometers to monitoring systems. Its robust construction ensures reliable signal transmission in harsh environments. Additionally, this cable suits various vibration monitoring applications.
Ordering Information Breakdown
The model number 200151-40-02-02 contains specific configuration details. The base model 200151 represents the accelerometer interface standard cable family. The “-40” option indicates a cable length of 4.0 meters. The “-02” armor option specifies blue cable without additional armor. Finally, the “02” coupling nut option means nylon coupling nuts on both ends.
Physical Construction
This cable uses a 4-conductor design for reliable signal transfer. Each conductor is 22 AWG stranded wire. A braided shield provides 85% minimum coverage for noise rejection. A drain wire simplifies ground connections at both ends. The outer jacket uses durable PVC material. Nickel-plated coupling nuts resist corrosion over time. The blue color without armor makes the 200151-40-02-02 easy to identify.
Connector and Sealing Features
Both ends of the 200151-40-02-02 have molded connectors. These connectors provide an IP67 seal to transducers and mating hardware. The IP67 rating means complete dust protection and water immersion resistance. Molded construction prevents moisture from entering the cable ends. Additionally, DC4 electrical insulating compound fills the connectors. This compound adds extra protection against moisture during thermal shock events.
Operating Temperature Range
The standard operating range spans -20°C to +100°C (-4°F to +212°F). Within this range, the cable flexes normally without damage. For lower temperatures, special installation practices apply. Specifically, the cable must not flex or bend below -20°C. Flexing the 200151-40-02-02 at very low temperatures may cause cable damage. Therefore, installers should secure the cable rigidly in cold environments.
Extended Temperature Capability
The cable assembly itself withstands -55°C to +121°C (-67°F to +250°F). This wider range applies to the cable materials and connectors. However, do not flex the cable at extreme low temperatures. The DC4 insulating compound requires 24 hours to fully cure. After curing, the compound provides its best moisture protection.
Minimum Bend Radius
The minimum bend radius for this cable is 63.5 mm (2.5 inches). Exceeding this radius may damage internal conductors. Installers should avoid sharp bends during routing. Use smooth curves when directing the 200151-40-02-02 through conduits or trays. Following this guideline ensures long cable life.
Installation Guidelines
Follow these steps to install the 200151-40-02-02 correctly.
-
Inspect the Cable: Check both molded connectors for damage. Ensure the nylon coupling nuts turn freely.
-
Route the Cable: Plan a path with bend radii above 63.5 mm. Avoid areas with extreme temperatures or moving machinery.
-
Connect to Accelerometer: Screw one end onto the accelerometer securely. Hand-tighten the nylon coupling nut only.
-
Connect to Monitor: Attach the other end to the monitoring system input. Verify proper orientation of the connector.
-
Secure the Cable: Use cable ties or clamps every 30 cm. Prevent any flexing if ambient temperature falls below -20°C.
-
Test Continuity: Measure pin-to-pin continuity before system power-up. The 200151-40-02-02 should show low resistance on all conductors.
Package Contents
Your 200151-40-02-02 shipment includes the following items:
-
One Bently Nevada 200151-40-02-02 accelerometer standard cable (4.0 meters)
-
Two nylon coupling nuts (pre-installed on connectors)
-
One plastic anti-static bag for protection
-
One cable identification label
Common FAQs
1. Can I cut the 200151-40-02-02 cable to a shorter length?
No, cutting the cable will void its IP67 seal rating. Order a different length variant of the 200151-40-02-02 family instead.
2. Is this cable compatible with all Bently Nevada accelerometers?
Yes, the 200151-40-02-02 works with most Bently Nevada accelerometer models. Always verify the connector type matches your sensor.
3. What does the DC4 compound cure time mean for installation?
The 24-hour cure time applies before thermal shock exposure. Install the 200151-40-02-02 and wait 24 hours before subjecting it to rapid temperature changes.
4. Can I use this cable in continuous high-moisture environments?
Yes, the IP67 molded connectors provide excellent moisture resistance. However, do not submerge the 200151-40-02-02 for extended periods.
5. Why are nylon coupling nuts specified instead of metal?
Nylon nuts prevent galvanic corrosion between dissimilar metals. They also reduce the risk of over-tightening the 200151-40-02-02 connectors.
Conclusion
The Bently Nevada 200151-40-02-02 offers a reliable connection for accelerometer signals. Its 4.0 meter length suits many machine monitoring installations. Molded IP67 connectors protect against moisture and dust. The 4-conductor shielded design ensures clean signal transmission. For durable and dependable accelerometer cabling, choose the 200151-40-02-02 for your vibration monitoring system.