GE Fanuc IC670GBI002 Bus Interface Unit



Introduction:
GE Fanuc IC670GBI002 Field Control Bus Interface Unit. Genius Bus protocol, supports 8 I/O modules, 128 bytes I/O, hot insertion, 24 VDC.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
IC670GBI002 Field Control Bus Interface Unit for Genius Networks
This IC670GBI002 unit serves as a Bus Interface Unit (BIU) for Field Control systems. The IC670GBI002 manages interface between a master PLC or computer over the Genius Bus. It functions as the header module for each Field I/O system. This unit supports up to eight Field Control I/O modules per system.
Technical Specifications
The IC670GBI002 exchanges data between Field I/O modules and the host computer. Each scan can handle 128 bytes of input data. Each scan can also handle 128 bytes of output data. The unit supports Genius Bus protocol for communication. It also handles Genius datagram communications effectively.
Data Exchange Capacity:
Maximum Input Data: 128 KB (or 128 bytes per scan)
Maximum Output Data: 128 KB (or 128 bytes per scan)
Supported Modules: Up to 8 Field Control I/O modules
Protocol: Genius Bus
CPU Redundancy: Hot Standby CPU supported
Power Specifications (DC Operation):
Nominal Supply Voltage: 24 VDC
Supply Voltage Range: 18 to 30 VDC
Power Consumption: 16.8 Watts maximum at full load
Inrush Current: 15 to 50 Amps peak
Inrush Duration: 3 milliseconds maximum
Power Supply Output: 6.5 VDC ±5%
Output Current to Modules: 1.4 Amps
Holdup Time: 10 milliseconds
Power Specifications (AC Operation):
Nominal AC Voltage: 115 Volts AC
Voltage Range: 90 to 135 Volts AC
Frequency: 47 to 63 Hertz
Power at 115 VAC: 48 Volt-Amps maximum
Holdup Time: 20 milliseconds maximum
Environmental Specifications:
Operating Temperature: 0 to 55 °C (32 to 131 °F)
Storage Temperature: -40 to 85 °C (-40 to 185 °F)
Relative Humidity: 5% to 95% (non-condensing)
Noise Immunity: Resistant to typical industrial noise levels
Reliability and Compliance:
MTBF (Module): 183,000 hours minimum
MTBF (Terminal Block): 600,000 hours minimum
Terminal Block Current: 16 milliamps maximum
Compliance: UL, CE, FCC standards
Hazardous Locations: Non-hazardous only (protect if used in hazardous areas)
Compatible Host Systems:
Series 90-30 PLCs
Series 90-70 PLCs
Series Six PLCs
Series Five PLCs
Genius hand-held monitors (version 4.6 or later)
The IC670GBI002 mounts on a terminal block for bus interface units. Power connections and communication cables terminate on this block. The unit mounts on a standard DIN rail of at least 108 mm (4.25 inches) size. Use a DIN rail made of good conductive material. The material should resist oxidation and corrosion. The DIN rail must connect to the grounding system. The unit accepts wire gauge of AWG #14.
Installation Guide
Follow these steps to install the IC670GBI002 properly. Mount the terminal block on a standard DIN rail. Ensure the DIN rail connects to the grounding system. Use a DIN rail at least 108 mm (4.25 inches) long. Attach the IC670GBI002 to the terminal block. Connect external power from 18 to 30 VDC (24 VDC nominal). Alternatively connect 90 to 135 VAC at 47 to 63 Hz. Terminate the Genius Bus communication cables to the terminal block. Install up to eight Field Control I/O modules after the BIU. Ensure you use appropriate module versions for hot insertion. Power up the system and verify normal operation. Use a hand-held monitor version 4.6 or later for diagnostics. Replace the unit without reconfiguring I/O wiring when needed.
What’s in the Box
Please check the package contents upon delivery.
IC670GBI002 Bus Interface Unit (1 unit)
Terminal strip for power and communication (1 piece)
Installation instruction sheet (1 piece)
Common FAQs
1. How many I/O modules can the IC670GBI002 support?
This Bus Interface Unit supports up to eight Field Control I/O modules. Each module connects to the BIU through the backplane.
2. What communication protocol does this BIU use?
The IC670GBI002 uses the Genius Bus protocol. It also supports Genius datagram communications and works with Series 90-30, 90-70, Six, and Five PLCs.
3. Does this unit support hot insertion and removal?
Yes, the IC670GBI002 supports hot insertion and removal. You can replace the unit without reconfiguring I/O wiring. The unit also supports CPU redundancy.
4. What is the MTBF rating for this module?
The module has a minimum MTBF of 183,000 operating hours. The terminal block has a higher rating of 600,000 hours minimum.
5. What power sources work with the IC670GBI002?
This unit accepts either 24 VDC (18-30 VDC range) or 115 VAC (90-135 VAC at 47-63 Hz). Power consumption is 16.8 Watts for DC or 48 VA for AC operation.