Allen-Bradley 1747-UIC USB to DH-485 Interface Converter



Introduction:
USB to DH-485 interface converter for SLC 500 controllers. 19.2 Kbps communication rate. Powered directly from USB port.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
Converter Function and Application
The Allen-Bradley 1747-UIC is a USB to DH-485 Interface Converter for the SLC 500 platform. This converter gives computers with USB ports a direct connection to DH-485 networks. Compatible devices include SLC 500, MicroLogix, and ControlLogix controllers as well as PanelView terminals with DH-485 ports. Consequently, the 1747-UIC bridges modern PCs with legacy DH-485 equipment.
Port Configuration and Connectivity
The 1747-UIC comes with two switch-selectable DH-485 ports for flexible network connections. An RJ-45 (Ethernet style) port provides direct connection to SLC 500, 5/01, 5/02, 5/03, AIC, and PanelView devices. A single RS-232 DB9 port is also available for additional connectivity. Therefore, the converter supports multiple connection methods for various applications.
Power and Isolation
The 1747-UIC is powered entirely by the USB port of the connected computer. Consequently, no external power supply is required for operation. The converter provides 500V DC circuit isolation between the power source and the DH-485 common. This isolation protects your computer from electrical noise and potential ground loops.
Technical Specifications
General Specifications
Manufacturer: Rockwell Automation
Brand: Allen-Bradley
Part Number: 1747-UIC
Series: SLC 500
Module Type: USB to DH-485 Interface Converter
UPC: 10662073052729
Communication Specifications
| Parameter | Value |
|---|---|
| Communication Ports | USB and DH-485 |
| DH-485 Ports | 2 (switch-selectable) |
| Additional Ports | RJ-45 (Ethernet style), RS-232 DB9 |
| Communication Rate (DH-485) | 19,200 bits/second (19.2 Kbps) |
| USB Transfer Speed | 12 Mbps |
Power Specifications
| Parameter | Value |
|---|---|
| Power Source | Computer’s USB port |
| USB Power Consumption | Less than 100 mA |
| Backplane Current (5V) | 600 milliamps (reference) |
| Backplane Current (24V) | 90 milliamps (reference) |
| Circuit Isolation | 500V DC between power and DH-485 common |
Environmental Specifications
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Weight | 1 pound (0.45 kilograms) |
Physical Dimensions
| Dimension | Inches | Millimeters |
|---|---|---|
| Length | 4.29 in | 109 mm |
| Width | 1.99 in | 50.6 mm |
| Height | 1.22 in | 31 mm |
Compatible Devices
The 1747-UIC works with various Rockwell Automation products.
| Device Family | Specific Models |
|---|---|
| SLC 500 Controllers | SLC 5/01, 5/02, 5/03 |
| MicroLogix Controllers | Various models with DH-485 |
| ControlLogix Controllers | Via DH-485 interfaces |
| PanelView Terminals | Models with DH-485 ports |
| AIC (Advanced Interface Converter) | For network expansion |
Installation Guide
Follow these steps to install the Allen-Bradley 1747-UIC correctly.
Install Drivers: First, download and install the latest USB drivers from Rockwell Automation.
Connect USB Cable: Next, plug the 1747-UIC into an available USB port on your computer.
Wait for Recognition: Then, allow the operating system to recognize the new hardware.
Select DH-485 Port: After that, set the switch to select the appropriate DH-485 port.
Connect Target Device: Meanwhile, connect your SLC 500 or other device to the RJ-45 or DH-485 port.
Configure Communication: Finally, set your programming software to use the virtual COM port.
The 1747-UIC requires no external power supply for operation. Therefore, ensure your computer’s USB port provides sufficient power. In addition, avoid connecting the converter through unpowered USB hubs. Consequently, proper installation ensures reliable DH-485 communication.
Package List
The package includes the following physical items.
Allen-Bradley 1747-UIC USB to DH-485 interface converter (1 piece)
USB cable (typically included)
Product label with part number and specifications
Anti-static protective bag for safe transport
*Note: DH-485 and RS-232 cables are not included. Driver software is available for download from Rockwell Automation. No programming software is provided with this converter.*
Frequently Asked Questions (FAQ)
1. What is the purpose of the 1747-UIC converter?
The Allen-Bradley 1747-UIC allows modern computers with USB ports to connect to DH-485 networks. Therefore, it bridges the gap between legacy DH-485 devices and contemporary PCs. Compatible devices include SLC 500, MicroLogix, ControlLogix, and PanelView terminals. Consequently, you can program and monitor older equipment without legacy communication hardware.
2. Does the 1747-UIC require an external power supply?
No, the Allen-Bradley 1747-UIC is powered entirely by the computer’s USB port. Therefore, no external power supply is needed for operation. The converter consumes less than 100 mA from the USB port. Consequently, it works with most laptop and desktop USB ports without issue.
3. What communication ports are available on the 1747-UIC?
The Allen-Bradley 1747-UIC includes multiple communication ports. Two switch-selectable DH-485 ports are provided for network connections. An RJ-45 (Ethernet style) port connects directly to SLC 500 and PanelView devices. A single RS-232 DB9 port offers additional connectivity. Consequently, the converter adapts to various connection scenarios.
4. What is the communication rate of the 1747-UIC?
The Allen-Bradley 1747-UIC communicates at 19,200 bits per second (19.2 Kbps) on the DH-485 network. Therefore, it matches the standard DH-485 communication rate for SLC 500 and MicroLogix controllers. The USB transfer speed is 12 Mbps for fast data exchange with the computer. Consequently, the converter does not become a communication bottleneck.
5. What devices are compatible with the 1747-UIC?
The Allen-Bradley 1747-UIC works with SLC 500, MicroLogix, and ControlLogix controllers. It also connects to PanelView terminals with DH-485 ports. Specific SLC models include the 5/01, 5/02, and 5/03 processors. Consequently, the converter supports a wide range of legacy Rockwell Automation products.
6. Does the 1747-UIC provide electrical isolation?
Yes, the Allen-Bradley 1747-UIC provides 500V DC circuit isolation. This isolation exists between the power source (USB port) and the DH-485 common. Therefore, your computer is protected from electrical noise and ground loops. Consequently, reliable communication is maintained even in electrically noisy industrial environments.
7. What is the operating temperature range of the 1747-UIC?
The Allen-Bradley 1747-UIC operates between 0 and 60°C (32 and 140°F). Therefore, it suits typical industrial control room environments. The converter weighs 1 pound and measures 4.29 x 1.99 x 1.22 inches. Consequently, it is portable and easy to carry for field service applications.
Related Accessories
Enhance your DH-485 connectivity with these compatible parts.
DH-485 Cable: Allen-Bradley 1747-C13 for controller connections
RS-232 Cable: Allen-Bradley 1747-CP3 for serial connections
AIC Converter: Allen-Bradley 1761-NET-AIC for DH-485 network expansion
Programming Software: Allen-Bradley RSLogix 500 for SLC programming
USB Extension Cable: Standard USB 2.0 cable for extended reach
Always use genuine Allen-Bradley components with the 1747-UIC. Therefore, third-party cables may cause communication errors or connection failures. In addition, verify driver compatibility with your operating system before installation. Consequently, using authentic parts ensures optimal converter performance and reliable DH-485 communication.