Siemens 3RW4434-6BC44 | SIRIUS Soft Starter 113A 55kW


Introduction:
Siemens 3RW4434-6BC44 SIRIUS soft starter. 113A at 400V, 55kW standard, 196A inside-delta, 110kW, screw terminals.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Siemens 3RW4434-6BC44 – SIRIUS Soft Starter for High Feature Applications
The Siemens 3RW4434-6BC44 is a SIRIUS soft starter. Specifically, this device is designed for high feature applications. It includes an integrated bridging contact system and thyristors. Furthermore, it supports both standard and inside-delta circuit configurations. Consequently, this soft starter provides flexible motor starting solutions for various industrial loads.
Ordering Configuration and Product Identification
Product Brand Name: SIRIUS.
Product Equipment: Integrated bridging contact system with thyristors.
Item Designation (DIN EN 61346-2): Q.
Item Designation (DIN 40719/IEC 750): G.
Product Designation: Soft starters for high feature applications.
Terminal Type: Screw terminals for main and control circuits.
Therefore, the Siemens 3RW4434-6BC44 offers robust construction for demanding environments.
Standard Circuit Ratings (400V, 40°C)
Operating Current (Rated Value): 113 A.
Emitted Mechanical Power: 55,000 W (55 kW).
Operating Voltage Range: 200 to 460 V AC.
Voltage Tolerance: -15% / +10%.
Operating Frequency: 50 to 60 Hz rated.
Frequency Tolerance: -10% / +10%.
Continuous Operating Current: 115% of Ie at 40°C.
Thus, the 3RW4434-6BC44 delivers 55kW motor starting in standard configuration.
Inside-Delta Circuit Ratings (400V, 40°C)
Operating Current (Rated Value): 196 A.
Emitted Mechanical Power: 110,000 W (110 kW).
Operating Voltage Range: 200 to 460 V AC.
Voltage Tolerance: -15% / +10%.
Application Benefit: Higher power output from same soft starter.
Consequently, the Siemens 3RW4434-6BC44 handles 110kW motors in inside-delta configuration.
Temperature Derating Specifications
Operating Current at 40°C (Standard): 113 A.
Operating Current at 50°C (Standard): 100 A.
Operating Current at 60°C (Standard): 88 A.
Operating Current at 40°C (Inside-Delta): 196 A.
Operating Current at 50°C (Inside-Delta): 173 A.
Operating Current at 60°C (Inside-Delta): 152 A.
Derating Temperature Threshold: 40°C.
Minimum Load: 8% of I_M.
Adjustable Rated Current Range (min): 22 A.
Active Power Loss (Typical): 64 W at operating current (40°C).
Therefore, derating must be considered for elevated ambient temperatures.
230V Ratings (For Reference)
Standard Switching at 230V (40°C): 30,000 W (30 kW) at 40°C.
Inside-Delta at 230V (40°C): 55,000 W (55 kW) at 40°C.
200/208V Standard (50°C): 30 hp.
Thus, the Siemens 3RW4434-6BC44 adapts to lower voltage systems.
Control Electronics Specifications
Control Supply Voltage Type: AC.
Control Supply Voltage (50 Hz): 230 V AC.
Control Supply Voltage (60 Hz): 230 V AC.
Control Supply Frequency Rated Values: 50 Hz and 60 Hz.
Frequency Tolerance: -10% / +10%.
Control Supply Voltage Tolerance (60 Hz): -15% / +10%.
Fault Signal Display Type: Display integrated.
Consequently, the 3RW4434-6BC44 accepts standard 230V AC control supplies.
Product Functions and Protection Features
Intrinsic Device Protection: Yes.
Motor Overload Protection: Yes.
Thermal Resistor Motor Protection Evaluation: Yes.
External Reset: Yes.
Adjustable Current Limitation: Yes.
Inside-Delta Circuit: Yes.
Product Component for Engine Brake: Yes.
Substitute Values Connectable: Yes.
Therefore, the Siemens 3RW4434-6BC44 provides comprehensive motor protection.
Mechanical Dimensions and Mounting
Width: 170 mm.
Height: 200 mm.
Depth: 270 mm.
Mounting Type: Screw fixing.
Mounting Position: ±90° rotatable on vertical mounting plane, ±22.5° tiltable forward/backward.
Distance to Ranks Assembly (Upwards): 100 mm minimum.
Distance to Ranks Assembly (Sidewards): 5 mm minimum.
Distance to Ranks Assembly (Downwards): 75 mm minimum.
Installation Altitude (Max): 5,000 meters above sea level.
Cable Length (Max): 500 meters.
Number of Poles (Main Circuit): 3.
Protection Class: IP00.
Thus, proper spacing ensures adequate cooling and maintenance access.
Auxiliary Contacts Configuration
Number of NC Contacts: 0.
Number of NO Contacts: 3.
Number of Changeover Contacts: 1.
Consequently, the Siemens 3RW4434-6BC44 provides flexible auxiliary signaling.
Main Circuit Electrical Connections
Connection Type: Busbar connection.
Box Terminal Conductor Cross-Section (Front Clamping Point):
Finely stranded (with/without end processing): 16 to 70 mm².
Stranded: 16 to 70 mm².
Box Terminal Conductor Cross-Section (Back Clamping Point):
Finely stranded (with end processing): 16 to 70 mm².
Without end processing: 16 to 70 mm².
Stranded: 16 to 70 mm².
Box Terminal (Both Clamping Points):
Finely stranded with end processing: max. 1x 50 mm², 1x 70 mm².
Without end processing: max. 1x 50 mm², 1x 70 mm².
Stranded: max. 2x 70 mm².
AWG Conductors (Box Terminal):
Back clamping: 6 to 2/0 AWG.
Front clamping: 6 to 2/0 AWG.
Both clamping points: max. 2x 1/0 AWG.
DIN Cable Lug (Main Contacts):
Finely stranded: 16 to 95 mm².
Stranded: 25 to 120 mm².
AWG Conductors (DIN Cable Lug): 4 to 250 kcmil.
Therefore, flexible wiring options suit various installation requirements.
Auxiliary and Control Circuit Connections
Connection Type: Screw-type terminals.
Conductor Cross-Section (Solid): 2x (0.5 to 2.5 mm²).
Conductor Cross-Section (Finely stranded with end processing): 2x (0.5 to 1.5 mm²).
AWG Conductors (Auxiliary Contacts): 2x (20 to 14).
Finely Stranded with Wire End Processing: 2x (20 to 16).
Thus, the Siemens 3RW4434-6BC44 accommodates standard control wiring.
Ambient Conditions
Operating Ambient Temperature (Max): 60°C.
Storage Temperature Range: -25°C to +80°C.
Derating Temperature Threshold: 40°C.
Protection Class: IP00 (open type).
Certificates and Approvals: Available upon request.
Moreover, the 3RW4434-6BC44 withstands typical industrial environments.
Installation Guide
First, ensure the main supply is completely disconnected. Then, mount the Siemens 3RW4434-6BC44 on a vertical plane using screw fixing. Maintain 100 mm clearance above, 75 mm below, and 5 mm sideways. After that, connect the main circuit cables using appropriate busbar connections. Use 16-70 mm² conductors for standard wiring. For inside-delta configuration, connect the motor windings accordingly. Then, connect the 230V AC control supply to the designated terminals. Observe the -15% to +10% voltage tolerance. Next, connect the three NO auxiliary contacts and one changeover contact as needed. Then, configure the adjustable current limitation between 22A and rated current. Set the motor overload protection parameters appropriately. Subsequently, connect external reset if remote reset is required. Finally, apply power and verify proper operation. As a result, the Siemens 3RW4434-6BC44 will provide smooth motor starting.
Packaging List
One Siemens 3RW4434-6BC44 SIRIUS soft starter unit
One set of screw terminals for main and control circuits
One product documentation and parameter guide
One mounting hardware kit
Common FAQs
Q1: What is the difference between standard and inside-delta connection?
A: Standard connection delivers 113A (55kW at 400V). Inside-delta connection delivers 196A (110kW at 400V). Therefore, inside-delta doubles the power output from the same soft starter.
Q2: What control supply voltage does the Siemens 3RW4434-6BC44 require?
A: This soft starter requires 230V AC control supply. Both 50 Hz and 60 Hz are supported. The voltage tolerance is -15% to +10% at 60 Hz.
Q3: Does this soft starter include an integrated bypass contactor?
A: Yes, the 3RW4434-6BC44 includes an integrated bridging contact system. Therefore, no external bypass contactor is required. This reduces panel space and wiring complexity.
Q4: What is the maximum cable length for this soft starter?
A: The maximum cable length is 500 meters. This applies to cables between the soft starter and motor. Longer cable runs may require additional output filtering.
Q5: What ambient temperature derating applies to the Siemens 3RW4434-6BC44?
A: Rated current is specified at 40°C. At 50°C, derate to 100A (standard) or 173A (inside-delta). At 60°C, derate to 88A (standard) or 152A (inside-delta). Always maintain proper clearance for cooling.