Bently Nevada 330980-50-05 | NSv Proximitor Sensor 5.0m Panel Mount


Introduction:
Bently Nevada 330980-50-05 NSv Proximitor Sensor. 5.0 meter system length with panel mount. Multiple approvals. High RFI/EMI immunity.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Bently Nevada 330980-50-05 is an NSv Proximitor Sensor. It belongs to the 3300 XL series from Bently Nevada. This sensor shares similar features with the 3300 XL 8 mm Proximitor Sensor. The Bently Nevada 330980-50-05 has a thin design for flexible mounting. It fits in high-density DIN-rail or traditional panel configurations. Users trust this sensor for reliable proximity measurement applications.
Technical Specifications
The 330980-50-05 delivers advanced proximity sensing with high RFI immunity. Below are the complete technical details.
General Specifications
Manufacturer: Bently Nevada for industrial measurement reliability.
Product Type: NSv Proximitor Sensor.
Product Number: 330980-50-05 for precise identification.
Model: 330980 – NSv Proximitor Sensor.
Total Length and Mounting Option: 50 = 5.0 metre (16.4 feet) system length.
Mounting Configuration: Panel mount installation.
Agency Approval Option: 05 = Multiple approvals.
Physical Specifications
Proximitor Sensor Material: A380 aluminum for durability.
Proximitor Sensor Weight: 255 g (9 oz) for lightweight installation.
Design: Thin design for space-constrained applications.
Input and Probe Compatibility
Proximitor Sensor Input: Accepts one non-contacting 3300 RAM probe.
Compatible Probe: Also accepts 3300 NSv Proximity Probe.
Extension Cable: Works with standard extension cables.
System Length: 5.0 metres including probe and extension cable.
Power Requirements
Supply Voltage (No Barriers): Requires -17.5 Vdc to -26 Vdc.
Supply Voltage (With Barriers): Requires -23 Vdc to -26 Vdc.
Maximum Current Consumption: 12 mA maximum draw.
Linear Range Warning: Operation above -23.5 Vdc reduces linear range.
Supply Sensitivity: Less than 2 mV change per volt change in input voltage.
Output Specifications
Output Resistance: 50 Ω for stable signal transmission.
Output Type: Standard Proximitor Sensor output.
Signal Integrity: Maintains accuracy under varying supply conditions.
Environmental Specifications
Operating Temperature: -52°C to +100°C (-62°F to +212°F).
Storage Temperature: -52°C to +105°C (-62°F to +221°F).
Relative Humidity: 100% condensing with protected connectors.
Submersion Restriction: Non-submersible even with protection.
Humidity Testing: Tested to IEC 68-2-3 damp heat standard.
Advanced Features
RFI/EMI Immunity: Improved immunity for reliable operation.
CE Mark Approval: Achieves European CE mark without special mounting.
RFI Protection: Prevents adverse effects from high frequency radio signals.
Thin Design: Allows high-density DIN-rail installations.
Panel Mount Option: Supports traditional panel configurations.
Terminal and Wiring Features
Terminal Type: SpringLoc terminal strips for secure connections.
Installation Tools: No special tools required for wiring.
Connection Quality: Facilitates faster and highly robust field wiring.
Wire Retention: Spring mechanism holds wires firmly in place.
System Accuracy Conditions
Reference Temperature: Specs valid from 0°C to +45°C (+32°F to +113°F).
Maximum Altitude: Tested at 2000 metres maximum altitude.
Reference Power Supply: -24 Vdc for standard testing.
Reference Load: 10 kΩ load condition.
Reference Target: AISI 4140 steel target, 31 mm diameter or larger.
Reference Probe Gap: 1.0 mm (40 mils) gap setting.
Accuracy Note: Does not apply when using non-AISI 4140 steel targets.
Installation Guide
Follow these steps to install the Bently Nevada 330980-50-05 correctly.
Choose Mounting Location: Select a panel mounting surface.
Mark 4-Hole Footprint: Use the standard mounting hole pattern.
Drill Mounting Holes: Prepare holes for secure panel attachment.
Mount the Sensor: Screw the unit onto the panel surface.
Connect the Probe: Attach the 3300 RAM or NSv probe to the input.
Add Extension Cable: Connect the extension cable for 5.0 metre system length.
Apply Power: Supply -17.5 Vdc to -26 Vdc to the power terminals.
Verify Voltage: Ensure voltage stays below -23.5 Vdc for full linear range.
Wire the Output: Connect the 50 Ω output to your monitoring system.
Use SpringLoc Terminals: Insert wires without special tools.
Set Probe Gap: Adjust to 1.0 mm (40 mils) reference gap.
Test Operation: Verify sensor response across temperature range.
Installation Notes
System accuracy requires AISI 4140 steel target for calibration.
Panel mount option uses traditional mounting footprint.
SpringLoc terminals eliminate screw-type clamping mechanisms.
Multiple approvals cover various international standards.
The sensor satisfies CE mark without special shielded conduit.
Packaging List
This unit ships as a new and original product.
Bently Nevada 330980-50-05 NSv Proximitor Sensor
SpringLoc terminal strips (pre-installed)
Panel mount hardware kit
Product calibration certificate (AISI 4140 steel target)
Anti-static factory packaging box
Frequently Asked Questions (FAQ)
1. What is the system length of the 330980-50-05?
The Bently Nevada 330980-50-05 has a total system length of 5.0 metres (16.4 feet). This includes the probe and extension cable combined.
2. What probes are compatible with this NSv Proximitor Sensor?
The 330980-50-05 accepts one non-contacting 3300 RAM probe. It also accepts 3300 NSv Proximity Probe and extension cable combinations.
3. Does this sensor require special mounting for CE mark approval?
No, the Bently Nevada 330980-50-05 achieves CE mark approval without special mounting considerations. Its improved RFI/EMI immunity handles the requirements.
4. What is the reference gap setting for accurate measurements?
The 330980-50-05 uses a reference probe gap of 1.0 mm (40 mils). System accuracy specifications assume this gap setting.
5. Does system accuracy apply when using non-AISI 4140 steel targets?
No, the system accuracy and interchangeability specifications for Bently Nevada 330980-50-05 do not apply when calibrated to any target other than AISI 4140 steel.