DL100-22HA2102 | SICK 200 m Laser Distance Sensor



Introduction:
The SICK DL100-22HA2102 is a PROFIBUS DP laser distance sensor with a 0.15 m to 200 m range and integrated heating for operation down to -40 °C.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
What Is the SICK DL100-22HA2102?
The SICK DL100-22HA2102 is a phase-shift optical time-of-flight laser distance sensor built for long-range positioning in demanding environments. It measures from 0.15 m to 200 m on Diamond Grade reflective tape and communicates over PROFIBUS DP at up to 12 Mbit/s. For engineers evaluating a proximity probe alternative, this sensor combines a rugged aluminum die-cast housing with an integrated heating system that supports operation from -40 °C to +55 °C.
This unit belongs to the SICK Dx100 series and carries part number 1052693. Its visible red laser diode operates at 658 nm and is classified as Class 2 per IEC 60825-1:2014, with average optical power below 1 mW.

Key Specifications at a Glance
- Measurement range: 0.15 m to 200 m on Diamond Grade reflective tape.
- Repeatability: 0.5 mm to 1 mm, typical 0.5 mm at 1 σ.
- Measurement accuracy: Typically ±2 mm to ±3 mm.
- Maximum tracking velocity: 15 m/s.
- Maximum acceleration: 15 m/s².
- Supply voltage: DC 18 V to 30 V, reverse-polarity protected.
- Power consumption: Typically 25 W to 35 W with the internal heating element active.
- Operating temperature: -40 °C to +55 °C with heating active.
- Storage temperature: -40 °C to +75 °C.
- Enclosure rating: IP65 per EN 60529.
- Housing: Aluminum die-cast with acrylic glass (PMMA) optical window.
- Weight: Approximately 1,000 g.
- Dimensions (W x H x D): 69.4 mm x 82.5 mm x 100.2 mm.
How This unit Handles Harsh Conditions
Cold-storage and outdoor installations often push sensors beyond their rated limits. This unit addresses this with an integrated heating system that keeps the unit operational down to -40 °C. Because the heating element draws current, power consumption rises to a typical 25 W to 35 W, so the 18 V to 30 V DC supply must be sized accordingly. The IP65 enclosure and die-cast aluminum housing further protect the optics from dust and water jets, making the sensor suitable for washdown-adjacent areas and dusty yards.

Where This unit Fits in Your Operation
Automated storage and retrieval systems (ASRS) benefit from the 15 m/s tracking velocity and 15 m/s² acceleration, which allow the sensor to follow fast-moving stacker cranes without losing lock. In steel mills, the long 200 m range supports crane positioning across wide bays. Port and terminal operators use similar sensors for trolley and gantry positioning, where repeatability of 0.5 mm to 1 mm supports consistent container placement. For a proximity probe equivalent in high-speed logistics, This unit offers a field-proven alternative with PROFIBUS DP integration.
Integration and Electrical Connection
The sensor provides a PROFIBUS DP interface per EN 50170, supporting up to 12 Mbit/s. Electrical connections include a 4-pin male M12 for power and two 5-pin female M12 connectors (B-coded, SPEEDCON™) for PROFIBUS In/Out. Two push-pull digital outputs (PNP/NPN, configurable B/Q, ≤100 mA) and a multifunctional input are also available. When wiring into a PROFIBUS network, confirm cable types and termination with your supplier; an external gateway or connection module may be required depending on your controller architecture.
Selection Checklist for Buyers
Before specifying This unit, verify that your application uses Diamond Grade reflective tape, since the 200 m range depends on it. Check that the 18 V to 30 V DC supply can deliver the 25 W to 35 W consumed during heating. Confirm the ambient temperature stays within -40 °C to +55 °C during operation. Finally, ensure your control system supports PROFIBUS DP at the required baud rate. For a bently nevada probe replacement in long-range positioning, This unit is a rugged, dependable option built for demanding environments.
Frequently Asked Questions
What is the operating temperature range of the SICK unit?
The SICK unit operates from -40 °C to +55 °C with the integrated heating system active. Storage temperature ranges from -40 °C to +75 °C.
What supply voltage does This unit require?
The sensor requires DC 18 V to 30 V and is reverse-polarity protected. Power consumption is typically 25 W to 35 W when the heating element is active.
Is This unit a suitable proximity probe alternative?
Yes, This unit can serve as a proximity probe alternative for long-range positioning tasks. It offers 0.15 m to 200 m measurement on Diamond Grade tape and PROFIBUS DP communication.
What is the measurement accuracy of This unit?
Typical measurement accuracy is ±2 mm to ±3 mm, with repeatability of 0.5 mm to 1 mm (typical 0.5 mm at 1 σ).
How is This unit connected electrically?
Power uses a 4-pin male M12 connector. PROFIBUS In/Out uses two 5-pin female M12 connectors, B-coded with SPEEDCON™.
Contact PetroPartsOnline for parts suited to your application's requirements.
{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "DL100-22HA2102 | SICK 200 m Laser Distance Sensor", "mpn": "DL100-22HA2102", "sku": "DL100-22HA2102", "brand": {"@type": "Brand", "name": "SICK"}, "description": "What Is the SICK DL100-22HA2102? The SICK DL100-22HA2102 is a phase-shift optical time-of-flight laser distance sensor built for long-range positioning in demanding environments. It measures from 0.15 m to 200 m on Diamond Grade reflective tape and communicates over PROFIBUS DP at up to 12 Mbit/s. For engineers evaluating a proximity probe alternative, this sensor combines a rugged aluminum die-cast housing with an integrated heating system that supports operation from -40 °C to +55 °C. This uni", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/10/1793099292-api_image__fpee17255f.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/10/1793099298-api_image__fpf2dcb99b.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/10/1793099305-api_image__fpf8daac5b.jpg"]}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What is the operating temperature range of the SICK unit?", "acceptedAnswer": {"@type": "Answer", "text": "The SICK unit operates from -40 °C to +55 °C with the integrated heating system active. Storage temperature ranges from -40 °C to +75 °C."}}, {"@type": "Question", "name": "What supply voltage does This unit require?", "acceptedAnswer": {"@type": "Answer", "text": "The sensor requires DC 18 V to 30 V and is reverse-polarity protected. Power consumption is typically 25 W to 35 W when the heating element is active."}}, {"@type": "Question", "name": "Is This unit a suitable proximity probe alternative?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, This unit can serve as a proximity probe alternative for long-range positioning tasks. It offers 0.15 m to 200 m measurement on Diamond Grade tape and PROFIBUS DP communication."}}, {"@type": "Question", "name": "What is the measurement accuracy of This unit?", "acceptedAnswer": {"@type": "Answer", "text": "Typical measurement accuracy is ±2 mm to ±3 mm, with repeatability of 0.5 mm to 1 mm (typical 0.5 mm at 1 σ)."}}, {"@type": "Question", "name": "How is This unit connected electrically?", "acceptedAnswer": {"@type": "Answer", "text": "Power uses a 4-pin male M12 connector. PROFIBUS In/Out uses two 5-pin female M12 connectors, B-coded with SPEEDCON™. Contact PetroPartsOnline for parts suited to your application's requirements."}}]}]}